Development of a dose verification system for Vero4DRT using Monte Carlo method

被引:12
|
作者
Ishihara, Yoshitomo [1 ]
Sawada, Akira [1 ,2 ]
Nakamura, Mitsuhiro [1 ]
Miyabe, Yuki [1 ]
Tanabe, Hiroaki [3 ]
Kaneko, Shuji [1 ]
Takayama, Kenji [4 ]
Mizowaki, Takashi [1 ]
Kokubo, Masaki [3 ,4 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto 6220041, Japan
[2] Kyoto Coll Med Sci, Fac Med Sci, Dept Radiol Technol, Nantan, Japan
[3] Inst Biomed Res & Innovat, Div Radiat Oncol, Kobe, Hyogo, Japan
[4] Kobe City Med Ctr, Gen Hosp, Dept Radiat Oncol, Kobe, Hyogo, Japan
来源
关键词
Monte Carlo; multileaf collimator; Vero4DRT; intensity-modulated radiotherapy; MODULATED RADIATION-THERAPY; GUIDED RADIOTHERAPY SYSTEM; X-RAY HEAD; TREATMENT PLANNING SYSTEM; MULTILEAF COLLIMATOR; PHOTON BEAMS; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; SIMULATIONS; ACCELERATOR;
D O I
10.1120/jacmp.v15i6.4961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Vero4DRT is an innovative image-guided radiotherapy system employing a C-band X-ray head with gimbal mechanics. The purposes of this study were to propose specific MC models of the linac head and multileaf collimator (MLC) for the Vero4DRT and to verify their accuracy. For a 6 MV photon beam delivered by the Vero4DRT, a simulation code was implemented using EGSnrc. The linac head model and the MLC model were simulated based on its specification. Next, the percent depth dose (PDD) and beam profiles at depths of 15, 100, and 200 mm were simulated under source-to-surface distance of 900 and 1000 mm. Field size was set to 150 x 150 mm(2) at a depth of 100 mm. Each of the simulated dosimetric metrics was then compared with the corresponding measurements by a 0.125 cc ionization chamber. After that, intra-and interleaf leakage, tongue-and-groove, and rounded-leaf profiles were simulated for the static MLC model. Meanwhile, film measurements were performed using EDR2 films under similar conditions to simulation. The measurement for the rounded-leaf profile was performed using the water phantom and the ionization chamber. The leaf physical density and abutting leaf gap were adjusted to obtain good agreement between the simulated intra-and interleaf leakage profiles and measurements. For the MLC model in step-and-shoot cases, a pyramid and a prostate IMRT field were simulated, while film measurements were performed using EDR2. For the linac head, exclusive of MLC, the difference in PDD was < 1.0% after the buildup region. The simulated beam profiles agreed to within 1.3% at each depth. The MLC model has been shown to reproduce dose measurements within 2.5% for static tests. The MLC is made of tungsten alloy with a purity of 95%. The leaf gap of 0.015 cm and the MLC physical density of 18.0 g/cm(3), which provided the best agreement between the simulated and measured leaf leakage, were assigned to our MC model. As a result, the simulated step-and-shoot IMRT dose distributions agreed with the film measurements to within 3.3%, with exception of the penumbra region. We have developed specific MC models of the linac head and the MLC in the Vero4DRT system. The results have demonstrated that our MC models have high accuracy.
引用
收藏
页码:160 / 172
页数:13
相关论文
共 50 条
  • [1] A Feasibility Study of Independent Dose Verification for Vero4DRT
    Yamashita, M.
    Takahashi, R.
    Kokubo, M.
    Takayama, K.
    Tanabe, H.
    Sueoka, M.
    Ishii, M.
    Okuuchi, N.
    Iwamoto, Y.
    Tachibana, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3524 - 3524
  • [2] A feasibility study of independent verification of dose calculation for Vero4DRT using a Clarkson-based algorithm
    Yamashita, Mikiko
    Takahashi, Ryo
    Kokubo, Masaki
    Takayama, Kenji
    Tanabe, Hiroaki
    Sueoka, Masaki
    Ishii, Masao
    Tachibana, Hidenobu
    MEDICAL DOSIMETRY, 2019, 44 (01) : 20 - 25
  • [3] Estimation of extremely small field radiation dose for brain stereotactic radiotherapy using the Vero4DRT system
    Nakayama, Shinichi
    Monzen, Hajime
    Onishi, Yuichi
    Kaneshige, Soichiro
    Kanno, Ikuo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 52 - 58
  • [4] Validation of Monte Carlo simulation of 6 MV photon beam delivered by Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc
    Rostamzadeh, Maryam
    Popescu, I. Antoniu
    Mestrovic, Ante
    Gete, Ermias
    Bergman, Alanah M.
    Ishihara, Yoshitomo
    Nakamura, Mitsuhiro
    MEDICAL PHYSICS, 2019, 46 (11) : 5388 - 5388
  • [5] Development of hybrid dynamic tumor tracking irradiation using Vero4DRT: A preliminary study
    Sueoka, M.
    Sawada, A.
    Ishihara, Y.
    Yamada, M.
    Tanabe, H.
    Okada, Y.
    Suzuki, Y.
    Takayama, K.
    Kokubo, M.
    Hiraoka, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S227 - S227
  • [6] Multi-Institutional Comparison of Pre-Treatment Dose Calculation Verification for CyberKnife, Vero4DRT and Tomotherapy
    Tachibana, H.
    Uchida, Y.
    Yamashita, M.
    Nagata, H.
    Sato, A.
    Miyakawa, R.
    Maruyama, D.
    Okamoto, H.
    Nakamura, M.
    Kito, S.
    Hayashi, N.
    Shirata, R.
    Noda, S.
    Fukuma, H.
    Kojima, T.
    Takahashi, R.
    Kawai, D.
    Itano, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 2937 - 2937
  • [7] Monte Carlo simulation of 6-MV dynamic wave VMAT deliveries by Vero4DRT linear accelerator using EGSnrc moving sources
    Rostamzadeh, Maryam
    Ishihara, Yoshitomo
    Nakamura, Mitsuhiro
    Popescu, I. Antoniu
    Mestrovic, Ante
    Gete, Ermias
    Fedrigo, Roberto
    Bergman, Alanah Mary
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 206 - 218
  • [8] DYNAMIC TUMOR TRACKING RADIOTHERAPY WITH REAL-TIME MONITORING USING VERO4DRT
    Matsuo, Yukinori
    Ueki, Nami
    Takayama, Kenji
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Tanabe, Hiroaki
    Kaneko, Shuji
    Mizowaki, Takashi
    Monzen, Hajime
    Sawada, Akira
    Kokubo, Masaki
    Hiraoka, Masahiro
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S535 - S535
  • [9] Dynamic tumor tracking with the Vero4DRT system using a single fiducial marker for early stage lung cancer
    Collen, C.
    Poels, K.
    De Vin, T.
    Engels, B.
    Boussaer, M.
    Storme, G.
    Verellen, D.
    De Ridder, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S40 - S41
  • [10] Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system
    Ebe, Kazuyu
    Sugimoto, Satoru
    Utsunomiya, Satoru
    Kagamu, Hiroshi
    Aoyama, Hidefumi
    Court, Laurence
    Tokuyama, Katsuichi
    Baba, Ryuta
    Ogihara, Yoshisada
    Ichikawa, Kosuke
    Toyama, Joji
    MEDICAL PHYSICS, 2015, 42 (08) : 4745 - 4754