Organ and effective doses in newborn patients during helical multislice computed tomography examination

被引:28
|
作者
Staton, Robert J.
Lee, Choonik
Lee, Choonsik
Williams, Matt D.
Hintenlang, David E.
Arreola, Manuel M.
Williams, Jonathon L.
Bolch, Wesley E.
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Shands Healthcare Inc, Dept Radiol, Gainesville, FL 32610 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys. 90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52 degrees and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI100 measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ dose. Per cent differences in organ dose between the stylized and tomographic phantoms at 120 kVp and 12 mm collimator setting ranged from -25% (skin) to +164% (muscle) for head exams, -92% (thyroid) to +98% (ovaries) for chest exams, -144% (uterus) to +112% (ovaries) for abdominal exams, -98% (SI wall) to +20% (thymus) for pelvic exams and -60% (extrathoracic airways) to +13% (ovaries) for CAP exams. Better agreement was seen between the two phantom types for organs entirely within the scan field. In these cases, corresponding per cent differences in organ absorbed dose did not vary more than 17%. For all scans, the effective dose was found to range approximately 1-13 mSv across the scan parameters and scan regions. The largest effective dose occurred for CAP scans at 120 kVp.
引用
收藏
页码:5151 / 5166
页数:16
相关论文
共 50 条
  • [1] Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination
    Lee, Choonik
    Lee, Choonsik
    Staton, Robert J.
    Hintenlang, David E.
    Arreola, Manuel M.
    Williams, Jonathon L.
    Bolch, Wesley E.
    [J]. MEDICAL PHYSICS, 2007, 34 (05) : 1858 - 1873
  • [2] Morphologic examination of the temporal bone by cone beam computed tomography: Comparison with multislice helical computed tomography
    Dahmani-Causse, M.
    Marx, M.
    Deguine, O.
    Fraysse, B.
    Lepage, B.
    Escude, B.
    [J]. EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2011, 128 (05) : 230 - 235
  • [3] Assessment of organ and tissue doses from computed tomography examination
    Janeczek, J
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C426 - C428
  • [4] Imaging of coronary stent by multislice helical computed tomography
    Zhao, SH
    Nie, YK
    Cai, ZL
    Zhao, H
    Yang, L
    [J]. CIRCULATION, 2002, 106 (05) : 637 - 638
  • [5] High temporal resolution for multislice helical computed tomography
    Taguchi, K
    Anno, H
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 861 - 872
  • [6] Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted
    Theocharopoulos, Nicholas
    Damilakis, John
    Perisinakis, Kostas
    Tzedakis, Antonis
    Karantanas, Apostolos
    Gourtsoyiannis, Nicholas
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3846 - 3856
  • [7] Multislice computed tomography is effective in the detection of CAD
    不详
    [J]. FUTURE CARDIOLOGY, 2005, 1 (04) : 423 - 423
  • [8] DETERMINATIONS OF ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENTS FROM COMPUTED TOMOGRAPHIC EXAMINATION
    NISHIZAWA, K
    MARUYAMA, T
    TAKAYAMA, M
    OKADA, M
    HACHIYA, J
    FURUYA, Y
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757): : 20 - 28
  • [9] Diagnosis of the nutcracker phenomenon by multislice helical computed tomography angiography
    Fu, WJ
    Hong, BF
    Xiao, YY
    Yang, Y
    Cai, W
    Gao, JP
    Guo, G
    Wang, XX
    [J]. CHINESE MEDICAL JOURNAL, 2004, 117 (12) : 1873 - 1875
  • [10] Diagnosis of the nutcracker phenomenon by multislice helical computed tomography angiography
    符伟军
    洪宝发
    肖越勇
    杨勇
    蔡伟
    高江平
    郭刚
    王晓雄
    [J]. 中华医学杂志(英文版), 2004, (12) : 114 - 116