Standardized serum GM-CSF autoantibody testing for the routine clinical diagnosis of autoimmune pulmonary alveolar proteinosis

被引:80
|
作者
Uchida, Kanji [1 ,2 ]
Nakata, Koh [3 ]
Carey, Brenna [1 ]
Chalk, Claudia [1 ]
Suzuki, Takuji [1 ]
Sakagami, Takuro [1 ]
Koch, Diana E. [1 ]
Stevens, Carrie [1 ]
Inoue, Yoshikazu [4 ]
Yamada, Yoshitsugu [2 ]
Trapnell, Bruce C. [1 ,5 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Cincinnati, OH 45229 USA
[2] Univ Tokyo, Grad Sch Med, Tokyo, Japan
[3] Niigata Univ, Med & Dent Hosp, Niigata, Japan
[4] Natl Hosp Org, Kinki Chuo Chest Med Ctr, Sakai, Osaka, Japan
[5] Univ Cincinnati, Coll Med, Cincinnati, OH USA
基金
日本学术振兴会;
关键词
Pulmonary alveolar proteinosis; Granulocyte/macrophage-colony stimulating factor; Autoimmune disease; Autoantibodies; Enzyme linked immunosorbent assay; Diagnosis; COLONY-STIMULATING FACTOR; MACROPHAGE DIFFERENTIATION; DELETION; PATIENT; LUNG;
D O I
10.1016/j.jim.2013.11.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Autoantibodies against granulocyte/macrophage colony-stimulating factor (GMAbs) cause autoimmune pulmonary alveolar proteinosis (PAP) and measurement of the GMAb level in serum is now commonly used to identify this disease, albeit, in a clinical research setting. The present study was undertaken to optimize and standardize serum GMAb concentration testing using a GMAb enzyme-linked immunosorbent assay (GMAb ELISA) to prepare for its introduction into routine clinical use. The GMAb ELISA was evaluated using serum specimens from autoimmune PAP patients, healthy people, and GMAb-spiked serum from healthy people. After optimizing assay components and procedures, its accuracy, precision, reliability, sensitivity, specificity, and ruggedness were evaluated. The coefficient of variation in repeated measurements was acceptable (<15%) for well-to-well, plate-to-plate, day-to-day, and inter-operator variation, and was not affected by repeated freeze-thaw cycles of serum specimens or the reference standards, or by storage of serum samples at 80 degrees C. The lower limit of quantification (LLOQ) of the PAP patient-derived polyclonal GMAb reference standard (PCRS) was 0.78 ng/ml. Receiver operating characteristic curve analysis identified a serum GMAb level of 5 mu g/m1 (based on PCRS) as the optimal cut off value for distinguishing autoimmune PAP serum from normal serum. A pharmaceutical-grade, monoclonal GMAb reference standard (MCRS) was developed as the basis of a new unit of measure for GMAb concentration: one International Unit (IU) of GMAb is equivalent to 1 mu g/ml of MCRS. The median [interquartile range] serum GMAb level was markedly higher in autoimmune PAP patients than in healthy people (21.54 [12.83-3638] versus 0.08 [0.05-0.14] IU; n = 56, 38; respectively; P < 0.0001). Results demonstrate that serum GMAb measurement using the GMAb ELISA was accurate, precise, reliable, had an acceptable LLOQ and could be accurately expressed in standardized units. These findings support the use of this GMAb ELISA for the routine clinical diagnosis of autoimmune PAP and introduce a new unit of measure to enable standardized reporting of serum GMAb data from different laboratories. (C) 2013 Published by Elsevier B.V.
引用
收藏
页码:57 / 70
页数:14
相关论文
共 50 条
  • [1] SERIAL MEASUREMENT OF SERUM AUTOANTIBODY AGAINST GM-CSF AND CLINICAL COURSE IN PATIENTS WITH AUTOIMMUNE PULMONARY ALVEOLAR PROTEINOSIS
    Matsumuro, A.
    Hirose, M.
    Nakata, K.
    Arai, T.
    Sugimoto, C.
    Kohashi, Y.
    Tachibana, K.
    Kitaichi, M.
    Akira, M.
    Hayashi, S.
    Okada, M.
    Inoue, Y.
    RESPIROLOGY, 2012, 17 : 151 - 151
  • [2] A Mechanism For Acceleration Of Gm-Csf Autoantibody Production In Autoimmune Pulmonary Alveolar ProteINOSis
    Nakata, K.
    Nei, T.
    Motoi, N.
    Urano, S.
    Tazawa, R.
    Nakagaki, K.
    Suzuki, M.
    Takizawa, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [3] Reduced GM-CSF autoantibody in improved lung of autoimmune pulmonary alveolar proteinosis
    Ohashi, K.
    Sato, A.
    Takada, T.
    Arai, T.
    Kasahara, Y.
    Hojo, M.
    Nei, T.
    Nakayama, H.
    Motoi, N.
    Urano, S.
    Eda, R.
    Yokoba, M.
    Tsuchihashi, Y.
    Nasuhara, Y.
    Ishii, H.
    Ebina, M.
    Yamaguchi, E.
    Inoue, Y.
    Nakata, K.
    Tazawa, R.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 39 (03) : 777 - 780
  • [4] Mechanisms For Excessive Production Of GM-CSF Autoantibody In Autoimmune Pulmonary Alveolar Proteinosis
    Nei, T.
    Urano, S.
    Kaneko, C.
    Motoi, N.
    Takizawa, J.
    Tazawa, R.
    Nakagaki, K.
    Akagawa, K.
    Trapnell, B.
    Nakata, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [5] GM-CSF Inhalation Promotes the Clearance of GM-CSF Autoantibody in the Lung of Autoimmune Pulmonary Alveolar Proteinosis.
    Nakata, K.
    Ohashi, K.
    Tazawa, R.
    Inoue, Y.
    Trapnell, B. C.
    Terada, M.
    Nakayama, H.
    Takada, T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [6] Occupational inhalational exposure and serum GM-CSF autoantibody in pulmonary alveolar proteinosis
    Xiao, Yong-Long
    Xu, Kai-Feng
    Li, Yan
    Li, Yan
    Li, Hui
    Shi, Bin
    Zhou, Ke-Feng
    Zhou, Zheng-Yang
    Cai, Hou-Rong
    OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2015, 72 (07) : 504 - 512
  • [7] Neutralizing capacity of autoantibody against GM-CSF in patients with autoimmune pulmonary alveolar proteinosis
    Yamaguchi, Etsuro
    Kosaka, Kenshi
    Yonezawa, Toshiyuki
    Shibata, Hirofumi
    Matsubara, Ayako
    Kato, Toshio
    Tanaka, Hiroyuki
    Yokoe, Norihito
    Ito, Satoru
    Kubo, Akihito
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [8] Standardization of GM-CSF Autoantibody (autoAb) Assay for Autoimmune Pulmonary Alveolar Proteinosis (APAP).
    Kaneko, C.
    Urano, S.
    Motoi, N.
    Nei, T.
    Trapnell, B. C.
    Nakata, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [9] Clinical significance of serum anti-GM-CSF autoantibody levels in autoimmune pulmonary alveolar proteinosis
    Nishimura, Masaki
    Yamaguchi, Etsuro
    Takahashi, Ayumu
    Asai, Nobuhiro
    Katsuda, Eisuke
    Ohta, Toyohiro
    Ohtsuka, Yoshinori
    Kosaka, Kenshi
    Matsubara, Ayako
    Tanaka, Hiroyuki
    Yokoe, Norihito
    Kubo, Akihito
    Konno, Satoshi
    Baba, Kenji
    BIOMARKERS IN MEDICINE, 2018, 12 (02) : 151 - 159
  • [10] A mechanism for acceleration of GM-CSF autoantibody (GMAb) production in autoimmune pulmonary alveolar proteinosis (aPAP)
    Nakata, Koh
    Tanaka, Takahiro
    Tazawa, Ryushi
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44