The values of shear wave elastography in avoiding repeat fine-needle aspiration for thyroid nodules with nondiagnostic and undetermined cytology

被引:18
|
作者
Chen, Lin [1 ,2 ]
Shi, Yi-xin [1 ]
Liu, Ying-chun [1 ]
Zhan, Jia [1 ]
Diao, Xue-hong [1 ]
Chen, Yue [1 ]
Zhan, Wei-wei [2 ]
机构
[1] Fudan Univ, Huadong Hosp, Dept Ultrasound, 221 West Yanan Rd, Shanghai 200040, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Ultrasound, 197 2 Ruijin Rd, Shanghai 200025, Peoples R China
关键词
elasticity; shear wave elastography; thyroid carcinoma; thyroid nodule; ultrasonography; REAL-TIME ELASTOGRAPHY; ASSOCIATION GUIDELINES; RISK STRATIFICATION; ULTRASOUND; SYSTEM; CANCER; MALIGNANCY; LESIONS; ULTRASONOGRAPHY; MANAGEMENT;
D O I
10.1111/cen.13992
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the value of shear wave elastography (SWE) in avoiding repeat fine-needle aspiration of thyroid nodules with nondiagnostic and undetermined cytology. Methods A total of 232 thyroid nodules with nondiagnostic (n = 132) and undetermined (n = 100) cytology underwent ultrasound (US) and SWE, followed by repeat ultrasound (US)-guided fine-needle aspiration cytology (FNAC). The final diagnosis was based on cytological or pathological findings. The US and SWE characteristics of benign and malignant nodules were compared using the chi(2)-test. The receiver operating characteristic (ROC) curves of the thyroid imaging reporting and data system (TI-RADS) categories from the US and the E-Mean and E-SD from the SWE were graphed, and the areas under the curves (AUCs) were compared using a Z test. Results There were significant differences between the benign and malignant nodules in terms of the echogenicity, shape, margin, calcification and TI-RADS categories (all P < 0.05). The differences were significant between the malignant and benign nodules for E-Mean [(34.57 +/- 14.81) kPa vs. (19.18 +/- 7.09) kPa] and E-SD [(13.68 +/- 13.01) kPa vs. (3.97 +/- 2.58) kPa] (both P < 0.001). Though the difference in the AUCs of E-Mean (0.864) and E-SD (0.876) was not significant (P = 0.745), they both had higher diagnostic performances in comparison with TI-RADS categories (0.762) (all P < 0.05). Moreover, E-SD attained a sensitivity of 100% with a relatively higher specificity of 49.75% when its cut-off value was 3.3 kPa. Conclusions Shear wave elastography is a promising imaging method for reducing repeat FNAC for benign thyroid nodules with nondiagnostic and undetermined cytology when using E-SD as an index.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [1] Ultrasonographic Characteristics of Thyroid Nodules with Nondiagnostic and Atypia of Undetermined Significance in Fine-Needle Aspiration Cytology: Correspondence
    Bozer, Ahmet
    Daungsupawong, Hinpetch
    Wiwanitkit, Viroj
    [J]. JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2024, 108 (01):
  • [2] Nondiagnostic thyroid fine-needle aspiration cytology: Management dilemmas
    Chow, LS
    Gharib, H
    Goellner, JR
    van Heerden, JA
    [J]. THYROID, 2001, 11 (12) : 1147 - 1151
  • [3] Comparison of fine-needle aspiration with fine-needle capillary cytology in thyroid nodules
    Hatami, H.
    Samsami, M.
    Movahedinia, S.
    Salehi, B.
    Movahedinia, M.
    Ardeshir, M.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2023, 105 (02) : 162 - 165
  • [4] Fine-needle aspiration cytology of solitary thyroid nodules
    Ersöz, C
    Firat, P
    Uguz, A
    Kuzey, GM
    [J]. CANCER CYTOPATHOLOGY, 2004, 102 (05) : 302 - 307
  • [5] Nondiagnostic Fine-Needle Aspiration Biopsy of Thyroid Nodules: Outcomes and Determinants
    Jack, Gwendolyne Anyanate
    Sternberg, Scot B.
    Aronson, Mark D.
    Mukamal, Kenneth J.
    Oshin, Adebayo
    Hennessey, James V.
    [J]. THYROID, 2020, 30 (07) : 992 - 998
  • [6] Timing of the repeat thyroid fine-needle aspiration biopsy: does early repeat biopsy change the rate of nondiagnostic or atypia of undetermined significance cytology result?
    Kahramanca, Fatma Dilek Dellal
    Sacikara, Muhammet
    Kilicarslan, Aydan
    Ogmen, Berna
    Aydin, Cevdet
    Topaloglu, Oya
    Ersoy, Reyhan
    Cakir, Bekir
    [J]. ENDOCRINE, 2024,
  • [7] Optimal timing for a repeat fine-needle aspiration biopsy of thyroid nodule following an initial nondiagnostic fine-needle aspiration
    Deniwar, Ahmed
    Hammad, AbdulRahman Y.
    Ali, Daniah Bu
    Alsaleh, Nuha
    Lahlouh, Maha
    Sholl, Andrew B.
    Moroz, Krzysztof
    Aslam, Rizwan
    Thethi, Tina
    Kandil, Emad
    [J]. AMERICAN JOURNAL OF SURGERY, 2017, 213 (02): : 433 - 437
  • [8] Significance of nondiagnostic fine-needle aspiration of the thyroid
    Schmidt, T
    Riggs, MW
    Speights, VO
    [J]. SOUTHERN MEDICAL JOURNAL, 1997, 90 (12) : 1183 - 1186
  • [9] Benign fine-needle aspiration cytology of thyroid nodule: to repeat or not to repeat?
    Gabalec, Filip
    Cap, Jan
    Ryska, Ales
    Vasatko, Tomas
    Ceeova, Vera
    [J]. EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2009, 161 (06) : 933 - 937
  • [10] FINE-NEEDLE ASPIRATION CYTOLOGY IN PREOPERATIVE DIAGNOSIS OF THYROID NODULES
    GERSHENGORN, MC
    MCCLUNG, MR
    CHU, EW
    HANSON, TAS
    WEINTRAUB, BD
    ROBBINS, J
    [J]. ANNALS OF INTERNAL MEDICINE, 1977, 87 (03) : 265 - 269