Three-dimensional kinematics of the human knee with intracortical pin fixation

被引:0
|
作者
Ishii, Y [1 ]
Terajima, K [1 ]
Terashima, S [1 ]
Koga, Y [1 ]
机构
[1] NIIGATA UNIV, SCH MECH ENGN, NIIGATA 951, JAPAN
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee motion was measured with an instrumented spatial linkage (accuracy, linear +/- 500 mu m; angular, +/- 0.5 degrees) fixed with intracortical Kirschner wires in five healthy male volunteers (five knees, judged clinically to be normal), This technique allows an accurate description of the relative angular and linear movements between tibia and femur without the effect of skin movement relative to the bone and without the effect of changing muscle volume, Motion of the tibia relative to the femur was described in terms of three clinically meaningful rotations and three translations between full extension and 60 degrees flexion: (1) abduction and adduction: 3.4 degrees +/- 1.2 degrees; (2) internal and external rotation: 10.6 degrees +/- 2.8 degrees, representing screw home motion; (3) anterior and posterior: 5.2 +/- 1.7 mm, representing roll back phenomenon; (4) proximal and distal: 1.2 +/- 2.7 mm; and (5) medial and lateral: 1.1 +/- 2.6 mm.
引用
下载
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [1] A three-dimensional MRI analysis of knee kinematics
    Patel, VV
    Hall, K
    Ries, M
    Lotz, J
    Ozhinsky, E
    Lindsey, C
    Lu, Y
    Majumdar, S
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 283 - 292
  • [2] A reproducible method for studying three-dimensional knee kinematics
    Hagemeister, N
    Parent, G
    Van de Putte, M
    St-Onge, N
    Duval, N
    de Guise, J
    JOURNAL OF BIOMECHANICS, 2005, 38 (09) : 1926 - 1931
  • [3] The Role of Navigation in Knee Surgery and Evaluation of Three-Dimensional Knee Kinematics
    Huefner, Tobias
    Mellen, Rupert
    Kendoff, Daniel
    Zeichen, Johannes
    Zelle, Boris A.
    Fu, Freddie H.
    Krettek, Christian
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2005, 15 (01) : 64 - 69
  • [4] Three-dimensional measurements of scapular kinematics: Interrater reliability and validation of a skin marker-based model against an intracortical pin model
    Malmberg, Catarina
    Jensen, Stefan E.
    Michaud, Benjamin
    Andreasen, Kristine R.
    Holmich, Per
    Barfod, Kristoffer W.
    Bencke, Jesper
    HELIYON, 2024, 10 (08)
  • [5] Measuring three-dimensional knee kinematics under torsional loading
    Hemmerich, A.
    van der Merwe, W.
    Vaughan, C. L.
    JOURNAL OF BIOMECHANICS, 2009, 42 (02) : 183 - 186
  • [6] Three-dimensional in vivo quantification of knee kinematics in cerebral palsy
    Sheehan, Frances T.
    Seisler, Andrea R.
    Alter, Katharine E.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (02) : 450 - 458
  • [7] In vivo pre- and postoperative three-dimensional knee kinematics in unicompartmental knee arthroplasty
    Mochizuki, Tomoharu
    Sato, Takashi
    Tanifuji, Osamu
    Kobayashi, Kouichi
    Koga, Yoshio
    Yamagiwa, Hiroshi
    Omori, Go
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (01) : 54 - 60
  • [8] Dependence of Muscle Moment Arms on In Vivo Three-Dimensional Kinematics of the Knee
    Navacchia, Alessandro
    Kefala, Vasiliki
    Shelburne, Kevin B.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (03) : 789 - 798
  • [9] Dependence of Muscle Moment Arms on In Vivo Three-Dimensional Kinematics of the Knee
    Alessandro Navacchia
    Vasiliki Kefala
    Kevin B. Shelburne
    Annals of Biomedical Engineering, 2017, 45 : 789 - 798
  • [10] Reliability of a method for analyzing knee kinematics during three-dimensional gait
    Labbe, David R.
    Hagemeister, Nicola
    Tremblay, Mathieu
    de Guise, Jacques
    GAIT & POSTURE, 2008, 28 (01) : 170 - 174