Right arm injection of contrast medium reduces venous artifacts in head and neck multislice spiral computed tomography angiography

被引:3
|
作者
Fang, H. [1 ]
Song, Y. -L. [1 ]
Li, X. -S. [1 ]
Bi, Y. -M. [1 ]
Wang, P. [1 ]
Fan, H. -X. [1 ]
Meng, L. M. [1 ]
Hu, H. -X. [2 ]
机构
[1] Chinese PLA Air Force Gen Hosp, Dept Radiol, Beijing, Peoples R China
[2] Chinese PLA Air Force Gen Hosp, Dept Rehabil, Beijing, Peoples R China
关键词
Computed tomography; X-ray; Angiography; Head and neck artery; Image quality; Contrast medium; CAROTID CT ANGIOGRAPHY; IMAGE QUALITY; IMPROVES; ROW;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: We tested whether injection of contrast medium via right or left arm would affect venous artifacts on head and neck multislice spiral computed tomography (CT) angiography. PATIENTS AND METHODS: 326 patients were enrolled. Each patient was injected with 10 ml of contrast medium at 5 ml/sec. Time of peak contrast value plus an additional 1 sec was defined as delay time. Another 40 ml of contrast medium were injected with the same injection speed. The scanning area ranged from the aortic arch to the top of the head. Left and right forearms were used for intravenous injections of contrast medium in, respectively, 151 and 175 patients. Comparative analyses of image quality included determining contrast medium residues remaining in the superior vena cava, brachiocephalic vein, or subclavian vein, and comparisons of quality of three-dimensional CT angiography. RESULTS: In 75% of head and neck angiographies, the delay time of the common carotid artery ranged from 16 to 22 sec. In 60% of the images, the quality was graded as excellent, with the left arm injection resulting in delay time of > 23 sec and the right arm delay time of > 18 sec. The CT imaging quality after contrast injections via left or right arms was statistically significant (p < 0.05). The image quality after right arm injection was better than after left arm injection. CONCLUSIONS: Intravenous injection of contrast medium via right arm reduces artifacts from contrast medium residues and improves the image quality of head and neck CT angiography.
引用
收藏
页码:4698 / 4702
页数:5
相关论文
共 22 条
  • [1] Determination of the recipient vessels in the head and neck using multislice spiral computed tomography angiography before free flap surgery: A preliminary study
    Tan, Onder
    Kantarci, Mecit
    Parmaksizoglu, Duygu
    Uyanik, Ummugulsum
    Durur, Irmak
    JOURNAL OF CRANIOFACIAL SURGERY, 2007, 18 (06) : 1284 - 1289
  • [2] Effects of right- versus left-arm injections of contrast material on computed tomography of the head and neck
    You, Su Yeon
    Yoon, Dae Young
    Choi, Chul Soon
    Chang, Suk Ki
    Yun, Eun Joo
    Seo, Young Lan
    Lee, Yu-Jin
    Moon, Jeung Hee
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (05) : 677 - 681
  • [3] INTRAARTERIAL INJECTION OF IODINATED CONTRAST MEDIUM FOR CONTRAST ENHANCED COMPUTED TOMOGRAPHY OF THE EQUINE HEAD
    Carmalt, James L.
    Montgomery, James
    VETERINARY RADIOLOGY & ULTRASOUND, 2015, 56 (04) : 384 - 390
  • [4] Venous reflux on carotid computed tomography angiography: Relationship with left-arm injection
    Tseng, Ying-Chi
    Hsu, Hui-Ling
    Lee, Tsong-Hai
    Chen, Chi-Jen
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (03) : 360 - 364
  • [5] What is changed in contrast medium injection when using high-resolution multislice computed tomography?
    Passariello, R
    Catalano, C
    Pediconi, F
    Brillo, R
    MULTISLICE CT: A PRACTICAL GUIDE, 2001, : 22 - 27
  • [6] Venous return in acute ischaemic stroke patients measured during computed tomography angiography of head and neck
    Lasocha, Bartlomiej
    Grochowska, Anna M.
    Wrona, Pawel
    Brzegowy, Pawel J.
    Pulyk, Roman
    Slowik, Agnieszka
    Latacz, Pawel R.
    Popiela, Tadeusz J.
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2021, 55 (05) : 462 - 468
  • [7] Hemodialysis catheter integrity during mechanical power injection of iodinated contrast medium for computed tomography angiography
    Fides R. Schwartz
    Douglas S. Lewis
    Amy E. King
    F. Gregory Murphy
    Laurens E. Howle
    Charles Y. Kim
    Rendon C. Nelson
    Abdominal Radiology, 2021, 46 : 2961 - 2967
  • [8] Hemodialysis catheter integrity during mechanical power injection of iodinated contrast medium for computed tomography angiography
    Schwartz, Fides R.
    Lewis, Douglas S.
    King, Amy E.
    Murphy, F. Gregory
    Howle, Laurens E.
    Kim, Charles Y.
    Nelson, Rendon C.
    ABDOMINAL RADIOLOGY, 2021, 46 (06) : 2961 - 2967
  • [9] Biphasic contrast administration: A new injection protocol to reduce flow related artifacts and optimize the image quality in computed tomography pulmonary angiography
    Saremi, F
    Wilcox, A
    Palmer, S
    RADIOLOGY, 2000, 217 : 509 - 509
  • [10] Low risk of contrast nephropathy in high-risk patients undergoing spiral computed tomography angiography with the contrast medium iopromide and prophylactic oral hydratation
    Garcia-Ruiz, C
    Martinez-Vea, A
    Sempere, T
    Sauri, A
    Olona, M
    Peralta, C
    Oliver, A
    CLINICAL NEPHROLOGY, 2004, 61 (03) : 170 - 176