An explicit conditioning method for image reconstruction in electrical capacitance tomography

被引:6
|
作者
Taylor, Stephen H. [1 ]
Garimella, Suresh V. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
Image reconstruction; Sensitivity Factor Regularization (SFR); Capacitance tomography; ECf design; Electrode optimization; ALGORITHM; ELECTRODE;
D O I
10.1016/j.flowmeasinst.2015.10.009
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A new electrical capacitance tomography (ECT) image reconstruction method, termed Sensitivity Factor Regularization (SFR), is developed. The SFR method provides an explicit formulation for solving the image reconstruction problem that performs better than other explicit methods, such as linear backprojection and Tikhonov regularization, while providing the same computational efficiency. The computational ease of the SFR method renders it an attractive option for ECT where real-time imaging is required and theoretical statistical evaluation of proposed electrode configurations may readily be performed. A statistical study is conducted using SFR image reconstructions for investigating the impact of electrode density on image quality for a symmetric ECT system characterizing a square cross-section. A larger number of smaller electrodes allows more data to be gathered for use in image reconstruction, but degrades signal-to-noise ratio in the measurements. The statistical study using SFR clearly identifies a theoretical optimum electrode density that minimizes reconstructed image error for a given level of measurement noise. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [1] Anisotropic regularization method for electrical capacitance tomography image reconstruction
    [J]. Guo, Z. (guozhiheng2002@yahoo.com), 1600, Science Press (34):
  • [2] Direct image reconstruction for electrical capacitance tomography by using the enclosure method
    Cao, Zhang
    Xu, Lijun
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (10)
  • [3] A reconstruction method for electrical capacitance tomography based on image fusion techniques
    Olmos, A. Martinez
    Botella, G.
    Castillo, E.
    Morales, Diego P.
    Banqueri, J.
    Garcia, A.
    [J]. DIGITAL SIGNAL PROCESSING, 2012, 22 (06) : 885 - 893
  • [4] Image reconstruction algorithms for electrical capacitance tomography
    Yang, WQ
    Peng, LH
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (01) : R1 - R13
  • [5] Image Reconstruction Method with the Exploitation of the Spatial Correlation for Electrical Capacitance Tomography
    Lei, Jing
    Liu, Shi
    [J]. MEASUREMENT SCIENCE REVIEW, 2015, 15 (06): : 284 - 293
  • [6] Relevance Vector Machine Image Reconstruction Algorithm for Electrical Capacitance Tomography With Explicit Uncertainty Estimates
    Ospina-Acero, Daniel
    Marashdeh, Qussai M.
    Teixeira, Fernando L.
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (09) : 4925 - 4939
  • [7] Dynamic image reconstruction method for electrical capacitance tomography in multiphase flow measurement
    School of Civil Engineering, Henan Polytechnic University, Jiaozuo
    454000, China
    不详
    100190, China
    不详
    102206, China
    [J]. Yi Qi Yi Biao Xue Bao, 10 (2355-2362):
  • [8] Image reconstruction method of electrical capacitance tomography based on compressed sensing principle
    Wu, Xinjie
    Huang, Guoxing
    Wang, Jingwen
    Xu, Chao
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (07)
  • [9] An image reconstruction algorithm based on a revised regularization method for electrical capacitance tomography
    Zhao, JC
    Fu, WL
    Li, TS
    Wang, S
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 638 - 640
  • [10] A hybrid image reconstruction algorithm for electrical capacitance tomography
    Peng, Lihui
    Geng, Lu
    Nin, Sun
    [J]. MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 807 - +