Multidetector-row CT of the heart

被引:1
|
作者
Schoepf, UJ
Becker, CR
Hofmann, LK
Yucel, EK
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[2] Univ Munich, Klinikum Grosshadern, Inst Clin Radiol, D-81377 Munich, Germany
[3] Siemens Med Solut, Div CT, D-91301 Forchheim, Germany
[4] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
D O I
10.1016/j.rcl.2004.03.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite worldwide efforts aimed at primary and secondary prevention, heart disease is still the leading cause of death in the western world. There is great interest in developing tools for noninvasive assessment of the presence and degree of coronary artery disease. The advent of multidetector-row CT allows high-resolution Volume coverage of the entire thorax and motion-free imaging of the heart and adjacent vessels within one breathhold. An exciting application with significant potential for cardiac risk stratification, which may overcome the obvious limitations of coronary calcium imaging in the future, is the use of the cross-sectional nature of contrast-enhanced multidetector-row CT coronary angiography for assessment of total coronary artery plaque burden.
引用
收藏
页码:635 / +
页数:16
相关论文
共 50 条
  • [1] Multidetector-row CT of the heart
    Hofmann, LK
    Becker, CR
    Flohr, T
    Schoepf, UJ
    [J]. SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 135 - 145
  • [2] Multidetector-row CT of the heart
    Schoepf, UJ
    Becker, CR
    Hofmann, LK
    Yucel, EK
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (03) : 491 - +
  • [3] Multidetector-row CT of the airways
    Grenier, PA
    Beigelman-Aubry, C
    Fetita, C
    Martin-Bouyer, Y
    [J]. SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 146 - 157
  • [4] Multidetector-row CT: cardiosurgery indications
    Christopher Herzog
    Selami Dogan
    Gerhard Wimmer-Greinecker
    Joern O. Balzer
    Martin G. Mack
    Thomas J. Vogl
    [J]. European Radiology, 2003, 13 : 82 - 87
  • [5] Multidetector-row CT: cardiosurgery indications
    Herzog, C
    Dogan, S
    Wimmer-Greinecker, G
    Balzer, JO
    Mack, MG
    Vogl, TJ
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) : M82 - M87
  • [6] Multidetector-row helical CT enteroclysis
    Di Mizio, R
    Rollandi, GA
    Bellomi, M
    Meloni, GB
    Cappabianca, S
    Grassi, R
    [J]. RADIOLOGIA MEDICA, 2006, 111 (01): : 1 - 10
  • [7] Multidetector-row CT: economics and workflow
    Pottala, KM
    Kalra, MK
    Ouellette, K
    Sahani, D
    Thrall, JH
    Saini, S
    [J]. EUROPEAN RADIOLOGY, 2005, 15 : D149 - D152
  • [8] Multidetector-row helical CT enteroclysis
    Maglinte, DDT
    Bender, GN
    Heitkamp, DE
    Lappas, JC
    Kelvin, FM
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (02) : 249 - +
  • [9] Multidetector-row CT of lung cancer screening
    Jacobson, FL
    [J]. SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 168 - 175
  • [10] Multidetector-row CT and interstitial lung disease
    Hunsaker, AR
    [J]. SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 176 - 185