In Situ Generation of Prussian Blue by MIL-53 (Fe) for Point-of-Care Testing of Butyrylcholinesterase Activity Using a Portable High-Throughput Photothermal Device

被引:36
|
作者
Guo, Lan [1 ]
Zhang, Ya-Jie [1 ]
Yu, Yong-Liang [1 ]
Wang, Jian-Hua [1 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang 110819, Peoples R China
基金
中国国家自然科学基金;
关键词
3D printers - Biochemistry - Instrument testing;
D O I
10.1021/acs.analchem.0c03575
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Butyrylcholinesterase (BuChE), the primary source of serum cholinesterase activity, is an indispensable biochemical marker for clinical diagnosis of liver function and organophosphorus poisoning. The requirement for bulky and expensive instruments represents a huge hindrance for point-of-care testing (POCT) of BuChE, especially in resource-limited settings. Herein, an easy-operated, economic, and portable photothermal (PT) biosensing platform for high-throughput BuChE detection was rationally designed. BuChE could "light up" the PT signal through in situ generation of Prussian blue (PB) by MIL-53 (Fe), which allowed us to translate biological signals into temperature signals. Such temperature change signals could be monitored at high throughput (six samples for a single measurement) by a miniature self-made integrated PT device via combining separable 96-well plates, a three-dimensional (3D) printed sample bracket, 808 nm lasers, and thermometers, satisfying the requirement for rapid on-site detection in a large batch with low cost. In addition, the large specific surface area, 3D network structure, and high porosity of MIL-53 (Fe) offered a beneficial platform for its reaction with enzymatic hydrolysate, resulting in high sensing sensitivity and low detection limit (0.3 U L-1), which was at least 20 000 times lower than the normal human serum BuChE activity. This facile, affordable, and broad applicability PT sensing platform provides a beneficial reference for the rational design of other disease diagnostic approaches suitable for POCT.
引用
收藏
页码:14806 / 14813
页数:8
相关论文
共 2 条
  • [1] A portable, high-throughput real-time quantitative PCR device for point-of-care testing
    Yin, Juxin
    Tong, Jizhi
    Li, Jiale
    Shao, Guangye
    Xie, Bo
    Zhuang, Jianjian
    Bi, Gang
    Mu, Ying
    [J]. ANALYTICAL BIOCHEMISTRY, 2023, 674
  • [2] A portable, low-cost and high-throughput electrochemical impedance spectroscopy device for point-of-care biomarker detection
    Ye X.
    Jiang T.
    Ma Y.
    To D.
    Wang S.
    Chen J.