Perioperative management to improve neurologic outcome in thoracic or thoracoabdominal aortic stent-grafting

被引:82
|
作者
Weigang, Ernst
Hartert, Marc
Siegenthaler, Michael P.
Beckmann, Nicholas A.
Sircar, Ronen
Szabo, Gabor
Etz, Christian D.
Luehr, Maximilian
von Samson, Patrick
Beyersdorf, Friedhelm
机构
[1] Univ Hosp Freiburg, Dept Cardiovasc Surg, D-79106 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Neurosurg, D-79106 Freiburg, Germany
[3] Mt Sinai Med Ctr, Dept Cardiothorac Surg, New York, NY USA
[4] Univ Heidelberg, Dept Cardiac Surg, Heidelberg, Germany
来源
ANNALS OF THORACIC SURGERY | 2006年 / 82卷 / 05期
关键词
D O I
10.1016/j.athoracsur.2006.05.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Thoracic or thoracoabdominal aortic stent-graft repair has shown a reduction in morbidity and mortality rates due to the procedure's advantages ( no aortic cross-clamping, continuous distal aortic perfusion, no reperfusion injury). However, 3% to 12% of the patients are at risk of spinal cord ischemia. We investigated spinal cord protective measures with evoked potentials, cerebrospinal fluid drainage, and prevention of hypotension to minimize postoperative neurologic deficit. Methods. Between November 2000 and July 2005, vital parameters and spinal cord function were monitored, including cerebrospinal fluid pressure and transcranial motor-evoked and somatosensory-evoked potentials in 36 stent-graft procedures ( 31 patients) on the thoracic or thoracoabdominal aorta. Results. Stent-graft placement was technically successful in all patients. We achieved a survival rate of 100% without neurologic deficit after fast-track extubation. Eleven of 31 patients exhibited changes in evoked potentials during stent-graft deployment. In 12 of 31 patients ( including the 11 with evoked potential alterations), cerebrospinal fluid pressure exceeded 15 mm Hg. Cerebrospinal fluid drainage and vital parameter adjustment were executed in those instances. We observed intraoperative evoked potential total recovery in 10 of 11 patients after these interventions. Conclusions. Interventions to improve spinal cord perfusion led to total recovery of spinal function in most patients ( 10/11). Therefore, spinal cord protective measures with motor- and somatosensory-evoked potential monitoring, cerebrospinal fluid drainage, and prevention of hypotension can reduce the incidence of spinal cord ischemia and improve the neurologic outcome of patients undergoing endovascular thoracic or thoracoabdominal aortic repair.
引用
收藏
页码:1679 / 1687
页数:9
相关论文
共 50 条
  • [1] Expanding the indication for stent-grafting in thoracic aortic aneurysms
    Garlicki, Miroslaw
    Nowicki, Miroslaw
    Walecki, Jerzy
    Labus, Krzysztof
    Ehrlich, Marek
    Czub, Pawel
    Gil, Robert
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2006, 3 (01): : 83 - 87
  • [2] Endovascular stent-grafting for descending thoracic aortic aneurysm
    Heijmen, RH
    Deblier, IG
    Moll, FL
    Dossche, KM
    van den Berg, JC
    Overtoom, TT
    Ernst, SM
    Schepens, MA
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (01) : 5 - 9
  • [3] Endovascular stent-grafting can be considered as an initial management for thoracic aortic emergency
    Kurimoto, Yoshihiko
    Asai, Yasufumi
    Nakajima, Tomohiro
    Yamauchi, Akihiko
    Ito, Toshiro
    Ingu, Akira
    Hase, Mamoru
    Kawaharada, Nobuyoshi
    Higami, Tetsuya
    CIRCULATION, 2007, 116 (16) : 684 - 684
  • [4] Descending thoracic aortic rupture: Role of endovascular Stent-Grafting
    Morishita, K
    Kurimoto, Y
    Kawaharada, N
    Fukada, J
    Hachiro, Y
    Fujisawa, Y
    Abe, T
    ANNALS OF THORACIC SURGERY, 2004, 78 (05): : 1630 - 1634
  • [5] Complications after endovascular stent-grafting of thoracic aortic diseases
    Piffaretti, Gabriele
    Tozzi, Matteo
    Lomazzi, Chiara
    Rivolta, Nicola
    Caronno, Roberto
    Castelli, Patrizio
    JOURNAL OF CARDIOTHORACIC SURGERY, 2006, 1 (1)
  • [6] Complications after endovascular stent-grafting of thoracic aortic diseases
    Gabriele Piffaretti
    Matteo Tozzi
    Chiara Lomazzi
    Nicola Rivolta
    Roberto Caronno
    Patrizio Castelli
    Journal of Cardiothoracic Surgery, 1
  • [7] Thoracic Aortic Stent-Grafting for Acute, Complicated, Type B Aortic Dissections
    Ham, Sung Wan
    Rowe, Vincent L.
    Ochoa, Christian
    Chong, Terry
    Lee, William M.
    Baker, Craig J.
    Cohen, Robbin G.
    Cunningham, Mark J.
    Weaver, Fred A.
    Woo, Karen
    ANNALS OF VASCULAR SURGERY, 2011, 25 (03) : 333 - 339
  • [8] Endovascular stent-grafting of anastomotic pseudoaneurysms following thoracic aortic surgery
    Ito T.
    Kurimoto Y.
    Kawaharada N.
    Koyanagi T.
    Hashiguchi H.
    Yamashita A.
    Miyaki Y.
    Yamauchi A.
    Nakamura M.
    Higami T.
    General Thoracic and Cardiovascular Surgery, 2009, 57 (10) : 528 - 533
  • [9] Continued aortic aneurysmal expansion after thoracic endovascular stent-grafting
    Bakaeen, Faisal G.
    Coselli, Joseph S.
    LeMaire, Scott A.
    Huh, Joseph
    ANNALS OF THORACIC SURGERY, 2007, 84 (03): : 1007 - 1008
  • [10] Etiology of paraplegia in thoracic stent-grafting
    Hollier, LH
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 : 19 - 20