Empirical water precorrection for cone-beam computed tomography

被引:0
|
作者
Sourbelle, Katia [1 ]
Kachelriess, Marc [1 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We propose an algorithm to correct for the cupping artifact inherent in CT images due to the polychromatic nature of the spectrum. This method is empirical and does not require knowledge of the spectrum and of the attenuation coefficients. The method aims at linearizing the attenuation data using a precorrection function of polynomial form. The coefficients of the polynomial are determined from a fit of some linear combined reconstructed images of the polychromatic data with a defined template. This template is obtained from the reconstruction of the polychromatic rawdata and does not make any assumptions on the phantom size or of its positioning. It is shown that the fit can be performed easily solving only a linear system, making the method very fast. An example of application is given as the water precorrection. For this particular case, practical considerations are given on the definition of the template when an attenuating object table of unknown density is within the images. The method can generally correct for any kind of cupping such as scatter as well.
引用
收藏
页码:1871 / 1875
页数:5
相关论文
共 50 条
  • [1] Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography
    Kachelriess, M
    Sourbelle, K
    Kalender, WA
    [J]. MEDICAL PHYSICS, 2006, 33 (05) : 1269 - 1274
  • [2] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [3] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    [J]. DENTISTRY JOURNAL, 2019, 7 (03)
  • [4] Empirical dual energy calibration (EDEC) for cone-beam computed tomography
    Stenner, Philip
    Berkus, Timo
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2007, 34 (09) : 3630 - 3641
  • [5] Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography
    Kachelriess, Marc
    Berkus, Timo
    Stenner, Philip
    Kalender, Willi A.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2546 - 2550
  • [6] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [8] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [9] Simple ROI Cone-Beam Computed Tomography
    Maass, Clemens
    Knaup, Michael
    Sawall, Stefan
    Kachelriess, Marc
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3161 - 3168
  • [10] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10): : 3S - 6S