Stability analysis of a synchronous generator with simultaneous AC and rectified DC load

被引:0
|
作者
Yang, Q [1 ]
Ma, WM [1 ]
Wu, XS [1 ]
Sun, JZ [1 ]
机构
[1] Naval Univ Engn, Res Inst Power Elect Tech Applicat, Wuhan 430033, Peoples R China
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An equivalent circuit model of a synchronous generator with simultaneous AC and rectified DC load is presented in this paper. By use of the principle of, harmonic balance, which makes it possible to construct a state-space mathematical model of this system, the criterion of operation stability As derived for the system under small disturbance. It is shown that the AC load is favorable for improving the system stability and the generator parameters have considerable effects on the system. stability. The analytical results are compared with those obtained by simulation and experiment and good agreements are observed.
引用
收藏
页码:587 / 591
页数:5
相关论文
共 50 条
  • [1] Vibration analysis of a permanent magnet synchronous generator considering electromagnetic vibration sources under AC and DC load conditions
    Jung, Woo-sung
    Lee, Hoon-Ki
    Yang, Jun-Won
    Kim, Kyong-Hwan
    Park, Ji-Yong
    Shin, Kyung-Hun
    Choi, Jang-Young
    AIP ADVANCES, 2024, 14 (03)
  • [2] Analysis and comparison for rotor eddy current losses of permanent magnet synchronous generator according to dc and ac load conditions
    Jang, Seok-Myeong
    Kim, Hyun-Kyu
    Choi, Jang-Young
    Ko, Kyoung-Jin
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)
  • [3] Research on AC Output Characteristic of a Multiphase Permanent Magnet Generator with Rectified Load
    Wei, Kun
    Wang, Dong
    Yu, Xiwen
    Su, Zhenzhong
    Cheng, Siwei
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [4] Modeling and control of a synchronous generator with an active DC load
    Jadric, I
    Borojevic, D
    Jadric, M
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (02) : 303 - 311
  • [5] THEORETICAL STUDY OF 3 PHASE SALIENT POLE TYPE GENERATOR WITH SIMULTANEOUS AC AND BRIDGE RECTIFIED DC OUTPUT .1.
    FRANKLIN, PW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (02): : 543 - 551
  • [6] AC/DC Permanent Magnet Synchronous Generator Design And Research
    Sun, Yuping
    Kang, Kai
    MANUFACTURING PROCESS AND EQUIPMENT, PTS 1-4, 2013, 694-697 : 3076 - 3079
  • [7] Interleaving optimization in synchronous rectified DC/DC converters
    Gerber, M
    Ferreira, JA
    Hofsajer, IW
    Seliger, N
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 4655 - 4661
  • [8] Simultaneous compensation of distorted DC bus and AC side voltage using enhanced virtual synchronous generator in Islanded DC microgrid
    Mousavi, Mohammad Hossein
    Moradi, Hassan
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2025, 112 (01) : 151 - 176
  • [10] A Modified Boost Topology with Simultaneous AC and DC Load
    Ray, Olive
    Mishra, Santanu
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 2454 - 2459