Accuracy and Performance of continuous Glucose Monitoring with three Closed-Loop Studies with Home Phase under normal Living Conditions

被引:0
|
作者
Kojzar, Harald [1 ]
Thabit, Hood [2 ]
Leelarathna, Lalantha [2 ]
Wilinska, Malgorzata E. [2 ]
Elleri, Daniella [2 ]
Allen, Janet M. [2 ]
Lubina-Solomon, Alexandra [3 ]
Walkinshaw, Emma [3 ]
Stadler, Marietta [4 ]
Choudhary, Pratik [4 ]
Holzer, Manuel [1 ]
Mader, Julia K. [1 ]
Dellweg, Sibylle [5 ]
Benesch, Carsten [5 ]
Pieber, Thomas R. [1 ]
Arnolds, Sabine [5 ]
Heller, Simon R. [3 ]
Amiel, Stephanie A. [4 ]
Dunger, David [2 ]
Evans, Mark L. [2 ]
Hovorka, Roman [2 ]
机构
[1] Med Univ Graz, Dept Internal Med, Div Endocrinol & Metab, Graz, Austria
[2] Univ Cambridge, Welcome Trust MRC Inst Metab Sci, Cambridge, England
[3] Univ Sheffield, Acad Unit Diabet Endocrinol & Metab, Dept Human Metab, Sheffield, S Yorkshire, England
[4] Kings Coll London, Diabet Res Grp, London WC2R 2LS, England
[5] Profil Inst Stoffwechselforsch, Neuss, Germany
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:S145 / S146
页数:2
相关论文
共 50 条
  • [1] Accuracy of Continuous Glucose Monitoring During Three Closed-Loop Home Studies Under Free-Living Conditions
    Thabit, Hood
    Leelarathna, Lalantha
    Wilinska, Malgorzata E.
    Elleri, Daniella
    Allen, Janet M.
    Lubina-Solomon, Alexandra
    Walkinshaw, Emma
    Stadler, Marietta
    Choudhary, Pratik
    Mader, Julia K.
    Dellweg, Sibylle
    Benesch, Carsten
    Pieber, Thomas R.
    Arnolds, Sabine
    Heller, Simon R.
    Amiel, Stephanie A.
    Dunger, David
    Evans, Mark L.
    Hovorka, Roman
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 801 - 807
  • [2] Accuracy of Continuous Glucose Monitoring (CGM) under free-living conditions during three home closed loop studies
    Leelarathna, L.
    Thabit, H.
    Elleri, D.
    Allen, J. M.
    Lubina-Solomon, A.
    Mader, J. K.
    Benesch, C.
    Stadler, M.
    Pieber, T. R.
    Arnolds, S.
    Heller, S. R.
    Amiel, S. A.
    Dunger, D. B.
    Evans, M. L.
    Hovorka, R.
    DIABETOLOGIA, 2014, 57 : S406 - S407
  • [3] Continuous glucose monitoring and closed-loop systems
    Hovorka, R
    DIABETIC MEDICINE, 2006, 23 (01) : 1 - 12
  • [4] Accuracy of CGM During Closed-Loop Home Studies
    Kowalski, Aaron J.
    Crabtree, Vincent P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 770 - 772
  • [5] Use of continuous glucose monitoring and hybrid closed-loop therapy in pregnancy
    Benhalima, Katrien
    Yamamoto, Jennifer M.
    DIABETES OBESITY & METABOLISM, 2024,
  • [6] The Use of Continuous Glucose Monitoring (CGM) To Evaluate Performance of Closed-Loop Insulin Delivery Systems
    Nodale, Marianna
    Haidar, Ahmad
    Wilinska, Malgorzata E.
    Hovorka, Roman
    DIABETES, 2011, 60 : A64 - A64
  • [7] Feasibility of a Portable Bihormonal Closed-Loop System to Control Glucose Excursions at Home Under Free-Living Conditions for 48 Hours
    van Bon, Arianne C.
    Luijf, Yoeri M.
    Koebrugge, Rob
    Koops, Robin
    Hoekstra, Joost B. L.
    DeVries, J. Hans
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (03) : 131 - 136
  • [8] Analysis of Continuous Glucose Monitoring Data to Assess Outpatient Closed-Loop Studies: Considerations for Different Sensors
    Mitre, Tina Maria
    Legault, Laurent
    Rabasa-Lhoret, Remi
    Haidar, Ahmad
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (05) : 326 - 327
  • [9] Assessing Performance of Closed-Loop Insulin Delivery Systems by Continuous Glucose Monitoring: Drawbacks and Way Forward
    Hovorka, Roman
    Nodale, Marianna
    Haidar, Ahmad
    Wilinska, Malgorzata E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (01) : 4 - 12
  • [10] Towards the Development of an Artificial Pancreas: Continuous Glucose Monitoring and Closed-Loop Insulin Delivery
    Tamborlane, William
    HORMONE RESEARCH, 2008, 70 : 8 - 8