A Three-Zone Distance Protection Scheme Capable to Cope With the Impact of UPFC

被引:21
|
作者
Kong, Xiangping [1 ]
Yuan, Yubo [1 ]
Gao, Lei [1 ]
Li, Peng [1 ]
Li, Dun
Shi, Mingming [1 ]
Zhang, Liang [2 ]
机构
[1] State Grid Jiangsu Elect Power Co, Res Inst, Nanjing 211103, Jiangsu, Peoples R China
[2] Nanjing Inst Technol, Nanjing 211167, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Fault zone identification; R-L differential equation; three-zone distance protection; unified power flow controller (UPFC); POWER-FLOW CONTROLLER; TRANSMISSION-SYSTEM; RELAY; PERFORMANCE; LINES; FACTS;
D O I
10.1109/TPWRD.2017.2749309
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To improve the power transfer capability and reliability of the power grid, the unified power flow controller (UPFC) project has been put into operation in the western Nanjing power grid. Based on the practical project, the influence of UPEC on the distance protection is analyzed. To cope with that, the novel three-zone distance protection scheme is put forward. The zone 2 and zone 3 of the novel three-zone distance protection scheme are the same with those of conventional distance protection; however, the novel distance protection zone I is based on the parameter model of transmission line. According to the average value and fluctuation degree of the fault distance calculation results, the proposed distance protection zone 1 can effectively distinguish between the internal faults and external faults. More importantly, the proposed distance protection zone can realize effective cooperation with the conventional distance protection zone 2 and zone 3, to construct a complete three-zone distance protection scheme and guarantee the correct operation of the novel three-zone distance protection scheme. The simulation cases in the PSCAD/EMTDC software environment verifies that the proposed three-zone distance protection has excellent performance, and would not be affected by the operational mode and control parameters of UPFC.
引用
收藏
页码:949 / 959
页数:11
相关论文
共 18 条
  • [1] Design and Development of Three-Zone Distance Relay Protection Scheme at MATLAB Platform
    Dutta S.
    Chanda S.
    De A.
    [J]. Journal of The Institution of Engineers (India): Series B, 2021, 102 (01) : 31 - 40
  • [2] A scheme to implement distance protection capable to cope with overload
    Zhou, Zexin
    Liu, Huanzhang
    Wang, Delin
    Du, Dingxiang
    Wang, Xingguo
    [J]. Dianwang Jishu/Power System Technology, 2014, 38 (11): : 2948 - 2954
  • [3] Principe of distance protection capable to cope with overload
    [J]. Liu, Huanzhang, 1600, Power System Technology Press (38):
  • [4] Impact of UPFC on Distance Protection in AC Transmission System
    Cao Hong
    Cui Yu
    Liu Jing
    Cao Haiou
    Li Zhongqing
    Li Pei
    [J]. PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 234 - 238
  • [5] UPFC Operating Characteristics Impact on Transmission Line Distance Protection
    Khederzadeh, Mojtaba
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4238 - 4243
  • [6] A three-zone hypoxia chamber capable of regulating unique oxygen and carbon dioxide partial pressures simultaneously
    Sitte, Zachary R.
    Miranda, Abel A.
    DiProspero, Thomas J.
    Lockett, Matthew R.
    [J]. HARDWAREX, 2024, 19
  • [7] Impact Evaluation for Distance Protection of Southern Suzhou 500kV UPFC
    Zhang, Liang
    Zhou, Bin
    Li, Peng
    Yuan, Yubo
    Xu, Jingnan
    Kong, Xiangping
    [J]. PROCEEDINGS OF THE 2019 14TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2019), 2019, : 293 - 298
  • [8] Accelerated trip scheme for second-zone distance protection
    Sidhu, TS
    Ye, P
    Sachdev, MS
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) : 325 - 333
  • [9] Adaptive Third-Zone Distance Protection Scheme for Power System Critical Conditions
    Venkatanagaraju, Kasimala
    Biswal, Monalisa
    Malik, Om Parkash
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1401 - 1410
  • [10] Development of Three Zone Quadrilateral Adaptive Distance Relay for the Protection of Parallel Transmission line
    Srivani, S. G.
    Panduranga, Vittal K.
    Atla, Chandrasekhar Reddy
    [J]. 2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 324 - 329