Lead-selective PVC membrane electrodes based on bis(crown ether)s

被引:0
|
作者
Oh, KC
Kang, FC
Jeong, KS
Paeng, KJ [1 ]
机构
[1] Yonsei Univ, Dept Chem, Wonju 220710, South Korea
[2] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Lead-selective PVC membrane electrodes based on newly synthesized bis(crown ether)s containing 18-crown-6 moiety was prepared using standard PVC membrane composition. In order to monitor lead in environmental samples by lead sensor, especially good selectivity over alkali and all;aline earth metals has to be obtained. Thus, responses of the PVC membrane prepared with new bis(crown ether)s and Fluka ionophore V (crown ether) base to various cations include lead, alkali and alkaline earth metal ions were investigated for their use as a lead sensor. The polymeric Liquid membrane based on trans-18-crown-6 ether exhibits the best overall potentiometric performances as a lead-selective electrode in terms of a wide linear dynamic range (between 10(-6) and 10(-2) M, Pb2+), excellent detection limit (less than 10(-6) M) and good durability within limited error. The preferences of lead over other cations, such as Ag+, Hg2+, Na+, Ca2+ and even K+ in the aforementioned electrode are much better than the Fluka ionophore V system.
引用
收藏
页码:556 / 558
页数:3
相关论文
共 50 条
  • [1] CESIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS(CROWN ETHER)S
    KIMURA, K
    TAMURA, H
    SHONO, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 105 (02): : 335 - 340
  • [2] THALLIUM(I)-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS(CROWN ETHER)S
    TAMURA, H
    KIMURA, K
    SHONO, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 115 (01): : 115 - 121
  • [3] POTASSIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS(CROWN ETHER) AND POLY(CROWN ETHER)
    KIMURA, K
    MAEDA, T
    TAMURA, H
    SHONO, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 95 (01): : 91 - 101
  • [4] HYAMINE-1622 - SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS (CROWN ETHER)S
    KHALIL, MM
    ANALYTICAL LETTERS, 1993, 26 (10) : 2071 - 2078
  • [5] Lead-selective membrane electrodes based on dithiophenediazacrown ether derivatives
    Yang, XH
    Kumar, N
    Chi, H
    Hibbert, DB
    Alexander, PW
    ELECTROANALYSIS, 1997, 9 (07) : 549 - 553
  • [6] CESIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON CIS-BIS(CROWN ETHER)S
    TAMURA, H
    KIMURA, K
    SHONO, T
    NIPPON KAGAKU KAISHI, 1980, (10) : 1648 - 1650
  • [7] EFFECT OF PLASTICIZER ON THE SELECTIVITY OF POTASSIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS(CROWN ETHER)S
    TAMURA, H
    KIMURA, K
    SHONO, T
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1980, 53 (02) : 547 - 548
  • [8] THE SYNTHESIS OF BIS(BENZO-CROWN ETHER)S AND THEIR INCORPORATION INTO POTASSIUM-SELECTIVE PVC MEMBRANE ELECTRODES
    AN, HY
    WU, YJ
    ZHANG, ZJ
    IZATT, RM
    BRADSHAW, JS
    JOURNAL OF INCLUSION PHENOMENA AND MOLECULAR RECOGNITION IN CHEMISTRY, 1991, 11 (04): : 303 - 311
  • [9] Potassium-Selective PVC Membrane Electrodes Based on Newly Synthesized cis- and trans-Bis(crown ether)s
    Kum-Chul Oh
    Eun Chul Kang
    Young Lag Cho
    Kyu-Sung Jeong
    Eun-Ah Yoo
    Ki-Jung Paeng
    Analytical Sciences, 1998, 14 : 1009 - 1012
  • [10] Potassium-selective PVC membrane electrodes based on newly synthesized cis- and trans-bis(crown ether)s
    Oh, KC
    Kang, EC
    Cho, YL
    Jeong, KS
    Yoo, EA
    Paeng, KJ
    ANALYTICAL SCIENCES, 1998, 14 (05) : 1009 - 1012