Local temperature measurements in a full-scale utility boiler with overfire air

被引:19
|
作者
Tree, DR
Webb, BW
机构
[1] 134 Clyde Building, Brigham Young University, Provo
[2] 242 Clyde Building, Brigham Young University, Provo
关键词
pulverized coal boilers; NOx emission; temperature measurements;
D O I
10.1016/S0016-2361(97)00072-0
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Gas temperature and effluent NOx measurements were obtained in a full-scale (160 MWe) pulverized coal corner-fired utility boiler with separate overfire air. The measurements are the first of this kind in a full-scale boiler operated with overfire air and low-NOx burners. A test matrix of seven operating conditions was used to compare temperature and NOx with changes in overfire air, coal type, load and burner tilt. Peak temperatures were 1500-1600 degrees C and occurred just above the top burner. The measurements detailed the profile of temperature through a traverse of a coal burner, close-coupled overfire air port and separate overfire port. The data in the near-burner and overfire air regions showed evidence of reduced swirl as overfire air was increased. Little difference was seen in the temperatures for two coals with volatile fractions of 28 and 36 wt%. Temperature changes were quantified in the overfire air region for changes in burner tilt and load. Temperature was approximately the same in the overfire air region as load was decreased, but increased in this region as the burners were tilted from +5 degrees to -5 degrees. (C) 1997 Elsevier-Science Ltd.
引用
收藏
页码:1057 / 1066
页数:10
相关论文
共 50 条
  • [1] SCR deactivation in a full-scale cofired utility boiler
    Strege, Joshua R.
    Zygarlicke, Christopher J.
    Folkedahl, Bruce C.
    McCollor, Donald P.
    FUEL, 2008, 87 (07) : 1341 - 1347
  • [2] Full-scale measurements of indoor air flow
    Handa, K
    Pietrzyk, K
    17TH AIVC CONFERENCE - OPTIMUM VENTILATION AND AIR FLOW CONTROL IN BUILDING, PROCEEDINGS, VOLS 1 AND 2, 1996, : 273 - 281
  • [3] Optimization of Separated Overfire Air System for a Utility Boiler from a 3-MW Pilot-Scale Facility
    Zhang, Jianwen
    Chen, Kai
    Wang, Chang'an
    Xiao, Kun
    Xu, Xueyuan
    Che, Defu
    ENERGY & FUELS, 2013, 27 (02) : 1131 - 1140
  • [4] Measurements of air flow characteristics in a full-scale clean room
    Hu, SC
    Wu, YY
    Liu, CJ
    BUILDING AND ENVIRONMENT, 1996, 31 (02) : 119 - 128
  • [5] Experiments and Simulation on Co-Combustion of Semicoke and Coal in a Full-Scale Tangentially Fired Utility Boiler
    Wang, Pengqian
    Wang, Chang'an
    Du, Yongbo
    Feng, Qinqin
    Wang, Zhichao
    Yao, Wei
    Liu, Jiali
    Zhang, Jinping
    Che, Defu
    ENERGY & FUELS, 2019, 33 (04) : 3012 - 3027
  • [6] Full-scale study on halloysite fireside additive in 230 t/h pulverized coal utility boiler
    Kalisz, Sylwester
    Ciukaj, Szymon
    Mroczek, Kazimierz
    Tymoszuk, Mateusz
    Wejkowski, Robert
    Pronobis, Marek
    Kubiczek, Henryk
    ENERGY, 2015, 92 : 33 - 39
  • [7] Plasma assisted power coal combustion in the furnace of utility boiler: Numerical modeling and full-scale test
    Messerle, V. E.
    Karpenko, E. I.
    Ustimenko, A. B.
    FUEL, 2014, 126 : 294 - 300
  • [9] Temperature measurements using cars in a full scale 80 MW PF boiler
    Löfström, C
    Aldén, M
    Ljung, P
    INDUSTRIAL FURNACES AND BOILERS, VOL I, PROCEEDINGS, 2000, : 795 - 803
  • [10] MODEL FULL-SCALE PRESSURE MEASUREMENTS ON A GRANDSTAND
    APPERLEY, LW
    PITSIS, NG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1986, 23 (1-3) : 99 - 111