Optical detection of formaldehyde in air in the 3.6 μm range

被引:13
|
作者
Winkowski, Mateusz [1 ]
Stacewicz, Tadeusz [1 ]
机构
[1] Univ Warsaw, Inst Expt Phys, Fac Phys, Pasteura 5, PL-02093 Warsaw, Poland
来源
BIOMEDICAL OPTICS EXPRESS | 2020年 / 11卷 / 12期
关键词
INTERBAND CASCADE LASER; MULTIPASS ABSORPTION CELLS; VOLATILE ORGANIC-COMPOUNDS; TRACE-GAS DETECTION; INTERFERENCE-FRINGES; PHOTOACOUSTIC-SPECTROSCOPY; BREATH ANALYSIS; LUNG-CANCER; REDUCTION; SENSOR;
D O I
10.1364/BOE.405384
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The optical detector of formaldehyde designed for sensing cancer biomarkers in air exhaled from human lungs with possible application in free atmosphere is described. The measurements were performed at wavelengths ranging from 3595.77-3596.20 nm. It was stated that at the pressure of 0.01 atm this absorption band exhibits the best immunity to typical interferents that might occur at high concentration in human breath. Multipass absorption spectroscopy was also applied. The method of optical fringes quenching by wavelength modulation and signal averaging over the interferences period was presented. The application of such approaches enabled the detection limit of about single ppb to be achieved. (c) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:7019 / 7031
页数:13
相关论文
共 50 条
  • [1] LEDs for formaldehyde detection at 3.6 μm
    Krier, A
    Sherstnev, VV
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (03) : 428 - 432
  • [2] Sensitive detection of formaldehyde using an interband cascade laser near 3.6 μm
    Ren, Wei
    Luo, Longqiang
    Tittel, Frank K.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1062 - 1068
  • [3] DETECTION OF ETHANE, METHANE, FORMALDEHYDE AND WATER VAPOR IN THE 3.33 μm RANGE
    Winkowski, Mateusz
    Stacewicz, Tadeusz
    [J]. METROLOGY AND MEASUREMENT SYSTEMS, 2022, 29 (02) : 271 - 282
  • [4] Optical detection of formaldehyde
    Patty, Kira D.
    Gregory, Don A.
    [J]. SENSORS AND SYSTEMS FOR SPACE APPLICATIONS II, 2008, 6958
  • [5] MQW laser diode photoacoustic detection of formaldehyde in 2.3 μm spectral range
    Cihelka, J.
    Civis, S.
    Matulkova, I.
    [J]. 2007 ICTON MEDITERRANEAN WINTER CONFERENCE, 2007, : 61 - 65
  • [6] Absolute line intensities measurements and calculations for the 5.7 and 3.6 μm bands of formaldehyde
    Perrin, A.
    Jacquemart, D.
    Tchana, F. Kwabia
    Lacome, N.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2009, 110 (9-10): : 700 - 716
  • [7] Characterization of friction in the 3.6 m Devasthal optical telescope
    Kumar, T. S.
    Bastin, Christian
    Kumar, Brijesh
    [J]. GROUND-BASED AND AIRBORNE TELESCOPES VI, 2016, 9906
  • [8] Amperometric detection of gaseous formaldehyde in the ppb range
    Knake, R
    Jacquinot, P
    Hauser, PC
    [J]. ELECTROANALYSIS, 2001, 13 (8-9) : 631 - 634
  • [9] Faint Object Spectrograph for 3.6 m Devasthal Optical telescope
    Omar, Amitesh
    [J]. PROCEEDINGS OF THE 31ST MEETING OF THE ASTRONOMICAL SOCIETY OF INDIA, 2013, 2013, : 99 - 99
  • [10] Enclosure Design for the ARIES 3.6m Optical Telescope
    Pandey, A. K.
    Shukla, Vishal
    Bangia, Tarun
    Raskar, R. D.
    Kulkarni, R. R.
    Ghanti, A. S.
    [J]. GROUND-BASED AND AIRBORNE TELESCOPES IV, 2012, 8444