Breakthrough of toluene vapours in granular activated carbon filled packed bed reactor

被引:95
|
作者
Mohan, N. [1 ]
Kannan, G. K. [1 ]
Upendra, S. [1 ]
Subha, R. [2 ]
Kumar, N. S. [1 ]
机构
[1] DRDO, Def Bioengn & Electro Med Lab DEBEL, Bangalore, Karnataka, India
[2] SIT, Dept Chem Engn, Tumkur, Karnataka, India
关键词
Adsorption; Toluene; Breakthrough; Mass transfer zone (MTZ); VOLATILE ORGANIC-COMPOUNDS; GAS STREAMS; ADSORPTION; KINETICS; REMOVAL; ACETONE;
D O I
10.1016/j.jhazmat.2009.02.079
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this research was to determine the toluene removal efficiency and breakthrough time using commercially available coconut shell-based granular activated carbon in packed bed reactor. To study the effect of toluene removal and break point time of the granular activated carbon (GAC), the parameters studied were bed lengths (2, 3, and 4cm), concentrations (5, 10, and 15mg l(-1)) and flow rates (20,40, and 60 ml/min). The maximum percentage removal of 90% was achieved and the maximum carbon capacity for 5 mg l(-1) of toluene, 60 ml/min flow rate and 3 cm bed length shows 607.14 mg/g. The results of dynamic adsorption in a packed bed were consistent with those of equilibrium adsorption by gravimetric method. The breakthrough time and quantity shows that GAC with appropriate surface area can be utilized for air cleaning filters. The result shows that the physisorption plays main role in toluene removal. (C) 2009 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:777 / 781
页数:5
相关论文
共 50 条
  • [1] Adsorption of toluene on activated carbon in a packed bed
    San, JY
    Hsu, YC
    Wu, LJ
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (21) : 3229 - 3238
  • [2] Breakthrough data analysis of adsorption of toluene vapor in a fixed-bed of granular activated carbon
    Park, Sang-Wook
    Choi, Byoung-Sik
    Lee, Jae-Wook
    SEPARATION SCIENCE AND TECHNOLOGY, 2007, 42 (10) : 2221 - 2233
  • [3] A comparative adsorption/biosorption of phenol to granular activated carbon and immobilized activated sludge in a continuous packed bed reactor
    Gönen, F
    Aksu, Z
    CHEMICAL ENGINEERING COMMUNICATIONS, 2003, 190 (5-8) : 763 - 778
  • [4] Application of granular activated carbon packed-bed reactor in microwave radiation field to treat phenol
    Tai, HS
    Jou, CJG
    CHEMOSPHERE, 1999, 38 (11) : 2667 - 2680
  • [5] Adsorption Characteristics of Toluene in the Adsorption Bed Packed with Activated Carbon Fiber
    Kim, Sang Guk
    Chang, Ye Rim
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2008, 24 (02) : 220 - 228
  • [6] Phenols removal using ozonation-adsorption with granular activated carbon (GAC) in rotating packed bed reactor
    Karamah, E. F.
    Leonita, S.
    Bismo, S.
    INTERNATIONAL CONFERENCE ON CHEMISTRY AND MATERIAL SCIENCE (IC2MS) 2017, 2018, 299
  • [7] Biodegradation of dichloromethane in a granular activated carbon fluidized bed reactor
    Flanagan, WP
    WATER ENVIRONMENT RESEARCH, 1998, 70 (01) : 60 - 66
  • [9] Continuous adsorption and biotransformation of micropollutants by granular activated carbon-bound laccase in a packed-bed enzyme reactor
    Nguyen, Luong N.
    Hai, Faisal I.
    Dosseto, Anthony
    Richardson, Christopher
    Price, William E.
    Nghiem, Long D.
    BIORESOURCE TECHNOLOGY, 2016, 210 : 108 - 116
  • [10] Column performance of granular activated carbon packed bed for Pb(II) removal
    Dwivedi, Chandra P.
    Sahu, J. N.
    Mohanty, C. R.
    Mohan, B. Raj
    Meikap, B. C.
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 156 (1-3) : 596 - 603