A microplate-based enzymatic assay for the simultaneous determination of phenylalanine and tyrosine in serum

被引:28
|
作者
Wibrand, F [1 ]
机构
[1] John F Kennedy Inst, DK-2600 Glostrup, Denmark
关键词
phenylketonuria; phenylalanine determination; tyrosine determination; enzymatic assay; phenylalanine ammonia-lyase;
D O I
10.1016/j.cccn.2004.04.012
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Several methods have been reported for the quantitation of pbenylalanine (Phe) or tyrosine (Tyr) in blood, but the simultaneous determination of Phe and Tyr usually requires sophisticated equipment. Here we describe a simple and reliable microplate assay for measurement of Phe and Tyr in serum of patients with phenylketonuria (PKU). Methods: Serum was deproteinised and incubated with phenylalanine ammonia-lyase at 37 degreesC for 2 h. Phe and Tyr were converted to transcinnamate and trans-coumarate, respectively, which were determined UV spectrophotometrically. Results: The assay demonstrated linearity up to 3200 mumol/l Phe and 640 mumol/l Tyr. The sensitivity of the assay was 15 mumol/l for Phe and 5 mumol/l for Tyr. Analytical recovery was 105% and 97% for Phe and Tyr, respectively. The between-run coefficient of variation (CV) varied with concentration but was 4.7-18.8% for Phe and 4.2-8.8% for Tyr. The within-run CV was 2.7% for Phe and 6.5% for Tyr. Results obtained with the assay correlated well with those of an ion exchange chromatographic method. Conclusions: This novel assay is sensitive, accurate, precise and suitable for routine monitoring of PKU patients. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [1] A microplate-based screening assay for neuraminidase inhibitors
    Li, Aifeng
    Wang, Weihong
    Xu, Wenfang
    Gong, Jianzhi
    DRUG DISCOVERIES AND THERAPEUTICS, 2009, 3 (06): : 260 - 265
  • [2] Microplate-based carboxymethylcellulose assay for endoglucanase activity
    Xiao, ZZ
    Storms, R
    Tsang, A
    ANALYTICAL BIOCHEMISTRY, 2005, 342 (01) : 176 - 178
  • [3] A RAPID MICROPLATE-BASED FLUOROMETRIC ASSAY FOR PHAGOCYTOSIS
    UFF, CR
    POCKLEY, AG
    PHILLIPS, RKS
    IMMUNOLOGICAL INVESTIGATIONS, 1993, 22 (6-7) : 407 - 413
  • [4] ENZYMATIC ASSAY OF NEONATAL SERUM PHENYLALANINE AND TYROSINE USING A CENTRIFUGAL ANALYZER
    WELCH, CL
    BOON, SE
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1221 - 1221
  • [5] Quantitative Microplate-Based Growth Assay for Determination of Antifungal Susceptibility of Histoplasma capsulatum Yeasts
    Goughenour, Kristie D.
    Balada-Llasat, Joan-Miquel
    Rappleye, Chad A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (10) : 3286 - 3295
  • [6] Determination of ammonium using a microplate-based fluorometric technique
    Poulin, Patrick
    Pelletier, Emilien
    TALANTA, 2007, 71 (04) : 1500 - 1506
  • [7] Measurement of filter paper activities of cellulase with microplate-based assay
    Yu, Xiaoxiao
    Liu, Yan
    Cui, Yuxiao
    Cheng, Qiyue
    Zhang, Zaixiao
    Lu, Jia Hui
    Meng, Qingfan
    Teng, Lirong
    Ren, Xiaodong
    SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2016, 23 (01) : S93 - S98
  • [8] ENZYMATIC DETERMINATION OF PHENYLALANINE AND TYROSINE - IMPROVED METHOD
    FARBER, SJ
    REPIQUE, EV
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1017 - 1017
  • [9] A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method)
    Visvanathan, Rizliya
    Jayathilake, Chathuni
    Liyanage, Ruvini
    FOOD CHEMISTRY, 2016, 211 : 853 - 859
  • [10] Analytical Parameters of the Microplate-Based ORAC-Pyrogallol Red Assay
    Ortiz, Rocio
    Antilen, Monica
    Speisky, Hernan
    Aliaga, Margarita E.
    Lopez-Alarcon, Camilo
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (05) : 1562 - 1566