In vitro evaluation of a mechanical testing chewing simulator

被引:113
|
作者
Steiner, Martin [1 ]
Mitsias, Miltiadis E. [1 ]
Ludwig, Klaus [1 ]
Kern, Matthias [1 ]
机构
[1] Christian Albrechts Univ Kiel, Dept Prosthodont Propaedeut & Dental Mat, D-24105 Kiel, Germany
关键词
Chewing simulator; In vitro; Simulation device; Force-profile; Loading; FRACTURE STRENGTH; WEAR; FORCE; COMPOSITE; DENTURES; SYSTEMS; LEAKAGE; TEETH;
D O I
10.1016/j.dental.2008.09.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. in this in vitro study, the force-profile of a commonly used chewing simulator (Williytec, Munich, Germany) utilizing fixed weights for loading was evaluated. Methods. Using piezoelectric force sensors the maximum and mean values of the applied forces were recorded in three different load configurations in order to determine the repetition accuracy in one test chamber. The variation in resulting forces of the eight test loading-chambers when using three different loads and descending speeds was explored. Results. The simulator showed high load repetition accuracy between the different cycle rates. Significant differences (up to 38.2 +/- 0.4 N) were observed between the different specimen chambers. in addition, the recorded loads were generally both higher (up to 137.5 +/- 0.4 N) and lower than the nominal loads defined by the static weights. The extent of load variation at contact was highly dependent on the descending cross-speed and selected weight. Finally there were also ringing in the load profiles attributed to vibrations of the mechanical setup. Significance. Studies using weight-controlled chewing simulators should consider these effects when reporting results. In addition, calibrations should be performed to check uniformity of tests conditions for each test chamber. (C) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 50 条
  • [1] Using a chewing simulator for fatigue testing of metal ceramic crowns
    Heintze, S. D.
    Eser, A.
    Monreal, D.
    Rousson, V.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 : 770 - 780
  • [2] In Vitro Performance Testing of Medicated Chewing Gums
    Zieschang, Lisa
    Klein, Martin
    Kraemer, Johannes
    Windbergs, Maike
    DISSOLUTION TECHNOLOGIES, 2018, 25 (03): : 64 - 69
  • [3] Cardiorespiratory Mechanical Simulator for In Vitro Testing of Impedance Minute Ventilation Sensors in Cardiac Pacemakers
    Marcelli, Emanuela
    Cercenelli, Laura
    ASAIO JOURNAL, 2016, 62 (02) : 150 - 156
  • [4] Medicated Chewing Gums (MCGs): Composition, Production, and Mechanical Testing
    Al Hagbani, Turki
    Nazzal, Sami
    AAPS PHARMSCITECH, 2018, 19 (07): : 2908 - 2920
  • [5] Medicated Chewing Gums (MCGs): Composition, Production, and Mechanical Testing
    Turki Al Hagbani
    Sami Nazzal
    AAPS PharmSciTech, 2018, 19 : 2908 - 2920
  • [6] Evaluation of a new, mechanical ERCP simulator
    Healy, Joe
    Kimberly, James
    Baillie, John
    Rerniszewski, Stan
    Radziunas, Jeffrey
    Green, Ronald L.
    Wilkes, Barbara
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB231 - AB231
  • [7] Robotic Chewing Simulator for Dental Materials Testing on a Sensor-Equipped Implant Setup
    Conserva, Enrico
    Menini, Maria
    Tealdo, Tiziano
    Bevilacqua, Marco
    Pera, Francesco
    Ravera, Giambattista
    Pera, Paolo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (06) : 501 - 508
  • [9] A dual-axis chewing simulator for in vitro wear test of dental restoration materials
    Lü Xiao Ying
    M. Kern and J. R. Strub
    ChineseMedicalJournal, 1997, (12)
  • [10] A dual-axis chewing simulator for in vitro wear test of dental restoration materials
    Lu, XY
    Kern, M
    Strub, JR
    CHINESE MEDICAL JOURNAL, 1997, 110 (12) : 935 - 935