Determination of selenium in nutritional supplements and shampoos by flow injection-hydride generation-atomic fluorescence spectrometry

被引:39
|
作者
Gámiz-Gracia, L [1 ]
de Castro, MDL [1 ]
机构
[1] Univ Cordoba, Fac Sci, Div Analyt Chem, E-14004 Cordoba, Spain
关键词
selenium; atomic fluorescence; flow injection; microwave digestion;
D O I
10.1016/S0039-9140(99)00171-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of Se in pharmaceutical samples (nutritional supplements and shampoos) is proposed. The method involves two steps: (1) digestion of the samples and reduction of all forms of Se to Se-IV, which is complete in only 10 min by the use of a focused microwave digestor; and (2) continuous derivatisation (hydride formation) and spectrometry detection by atomic fluorescence. The method can be applied over a wide range of concentrations (0.3-1300 ng ml(-1) of Se) with good repeatability (RSD values lower than 4.6%). The method has been applied successfully to a reference material, and two different types of pharmaceuticals (namely, five different nutritional supplements-with Se present as sodium selenite and Se-methionine-and two shampoos, with selenium sulphide), in agreements with the certified and nominal values, respectively. Yields ranged between 86.5 and 104.8%, and good precision (RSD values lower than 4.2%) were obtained in all instances. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:875 / 880
页数:6
相关论文
共 50 条
  • [1] Determination of selenium in tricholoma giganteum by flow injection-hydride generation-atomic absorption spectrometry
    Liu Hong-gao
    Wang Yuan-zhong
    Li Tao
    Sha Ben-cai
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (09) : 1851 - 1853
  • [2] Determination of Selenium in Poultry Eggs by Flow Injection-Hydride Generation-Atomic Absorption Spectrometry
    Deng Shi-lin
    Li Xin-feng
    Guo Xiao-lin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (03) : 809 - 811
  • [3] Research on Optimization of Mathematical Model of Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry
    Cui Jian
    Zhao Xue-hong
    Wang Yan
    Xiao Ya-bing
    Jiang Xue-hui
    Dai Li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (01) : 246 - 251
  • [4] Optimization of microwave digestion for determination of selenium in human urine by flow injection-hydride generation-atomic absorption spectrometry
    Li, FS
    Goessler, W
    Irgolic, KJ
    ANALYTICAL COMMUNICATIONS, 1998, 35 (11): : 361 - 364
  • [5] Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry
    Elci, Latif
    Arslan, Zikri
    Tyson, Julian F.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 162 (2-3) : 880 - 885
  • [6] Determination of Selenium in Brass by Hydride Generation-Atomic Fluorescence Spectrometry
    Lu Jian-Ping
    Tang Qiong
    Wen Hui-Zhong
    Su Yuan
    Lu Ya-Ting
    Tang Yan-Kui
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (08) : 1291 - 1292
  • [7] Multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry
    Semenova, NV
    Leal, LO
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2003, 486 (02) : 217 - 225
  • [8] Determination of As, Sb, Se and Hg in paintings by flow injection-hydride generation-atomic absorption spectrometry
    Xia, Zhengbin
    Zhang, Yanhong
    Fenxi Yiqi/Analytical Instrumentation, 2002, (01):
  • [9] Mathematical model for optimization of flow injection-hydride generation atomic fluorescence spectrometry
    Van Elteren, Johannes T.
    Šlejkovec, Zdenka
    Das, Hendrik A.
    Spectrochimica acta, Part B: Atomic spectroscopy, 54 (02): : 311 - 320
  • [10] A mathematical model for optimisation of flow injection-hydride generation atomic fluorescence spectrometry
    van Elteren, JT
    Slejkovec, Z
    Das, HA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (02) : 311 - 320