A comparison of reconstruction algorithms for C-arm mammography tomosynthesis

被引:25
|
作者
Rakowski, Joseph T. [1 ]
Dennis, Michael J. [1 ]
机构
[1] Med Univ Ohio, Toledo, OH 43614 USA
关键词
tomosynthesis; algebraic reconstruction; iterative reconstruction; digital mammography;
D O I
10.1118/1.2219090
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angles to the reconstruction tomogram. The digital nature of the data allows for input images to be combined into the desired plane with the flexibility of generating tomograms of many separate planes from a single set of input data. Angular datasets were obtained of a low contrast detectability (LCD) phantom and cadaver breast utilizing a Lorad stereotactic biopsy unit with a coupled source and digital detector in a C-arm configuration. Datasets of 9 and 41 low-dose projections were collected over a 30 degrees angular range. Tomographic images were reconstructed using a Backprojection (BP) algorithm, an Iterative Subtraction (IS) algorithm that allows the partial subtraction of out-of-focus planes, and an Algebraic Reconstruction (AR) algorithm. These were compared with single view digital radiographs. The methods' effectiveness at enhancing visibility of an obscured LCD phantom was quantified in terms of the Signal to Noise Ratio (SNR), and Signal to Background Ratio (SBR), all normalized to the metric value for the single projection image. The methods' effectiveness at removing ghosting artifacts in a cadaver breast was quantified in terms of the Artifact Spread Function (ASF). The technology proved effective at partially removing out of focus structures and enhancing SNR and SBR. The normalized SNR was highest at 4.85 for the obscured LCD phantom, using nine projections and IS algorithm. The normalized SBR was highest at 23.2 for the obscured LCD phantom, using 41 projections and an AR algorithm. The highest normalized metric values occurred with the obscured phantom. This supports the assertion that the greatest value of tomosynthesis is in imaging fibroglandular breasts. The ASF performance was best with the AR technique and nine projections. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3018 / 3032
页数:15
相关论文
共 50 条
  • [1] Limited angle C-arm tomosynthesis reconstruction algorithms
    Malalla, Nuhad A. Y.
    Xu, Shiyu
    Chen, Ying
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [2] Ray tracing reconstruction investigation for C-arm tomosynthesis
    Malalla, Nuhad A. Y.
    Chen, Ying
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [3] Characterization of mammography tomosynthesis performance using a C-arm coupled source and detector
    Rakowski, J
    Dennis, M
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1725 - 1725
  • [4] Parallelizable 3D statistical reconstruction for C-arm tomosynthesis system
    Wang, BL
    Barner, K
    Lee, D
    [J]. MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 2171 - 2182
  • [5] Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis
    Dehghan, Ehsan
    Moradi, Mehdi
    Wen, Xu
    French, Danny
    Lobo, Julio
    Morris, W. James
    Salcudean, Septimiu E.
    Fichtinger, Gabor
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5290 - 5302
  • [6] Digital tomosynthesis of joints based on a C-arm system
    Lou, Hong
    Zhang, Qizhi
    Gibson, Clayton
    Li, Senhu
    Jiang, Huabei
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2005, 13 (01) : 1 - 8
  • [7] Digital TomoSynthesis (DTS) on a rotating C-arm system
    Koppe, R
    Klotz, E
    de Beek, JO
    [J]. CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1103 - 1103
  • [8] A comparison of reconstruction algorithms for breast tomosynthesis
    Wu, T
    Moore, RH
    Rafferty, EA
    Kopans, DB
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2636 - 2647
  • [9] Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm
    Claus, Bernhard E.
    Langan, David A.
    Al Assad, Omar
    Wang, Xin
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [10] Interventional C-Arm Tomosynthesis for Vascular Imaging: Initial Results
    Langan, David A.
    Claus, Bernhard E. H.
    Al Assad, Omar
    Trousset, Yves
    Riddell, Cyril
    Avignon, Gregoire
    Solomon, Stephen B.
    Lai, Hao
    Wang, Xin
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412