Comparison of three different plating techniques for the dorsum of the distal radius: A biomechanical study

被引:3
|
作者
Peine, R [1 ]
Rikli, DA [1 ]
Hoffmann, R [1 ]
Duda, G [1 ]
Regazzoni, P [1 ]
机构
[1] Kantonsspital, Chirurg Klin, CH-5001 Aarau, Switzerland
来源
关键词
distal radius fracture; plating; biomechanics;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three different plating techniques were used on experimentally produced dorsally displaced distal radius fractures in cadavers and were tested in 4-point bending: a AO 3.5-mm T plate (group 1), two 2.0-mm titanium plates 60 degrees to each other (group 2), and the AO pi plate (group 3). A metaphyseal defect was simulated by a dorsally open wedge osteotomy. The tests show that the 2-mm double-plating technique has superior stiffness and statistically equivalent bending and bone gap to failure compared with the AO 3.5-mm T plate or the pi plate when applied to the unstable distal radius fracture model. Copyright (C) 2000 by the American Society for Surgery of the Hand.
引用
收藏
页码:29 / 33
页数:5
相关论文
共 50 条
  • [1] Plating techniques for the dorsum of the distal radius - Reply
    Rikli, DA
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (04): : 776 - 777
  • [2] A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model
    Alluri, Ram K.
    Bougioukli, Sofia
    Stevanovic, Milan
    Ghiassi, Alidad
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 748.e1 - 748.e8
  • [3] Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study
    Osada, D
    Viegas, SF
    Shah, MA
    Morris, RP
    Patterson, RM
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01): : 94 - 104
  • [4] Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length
    Liu, Xiong
    Wu, Wei-dong
    Fang, Ya-feng
    Zhang, Mei-chao
    Huang, Wen-hua
    [J]. PLOS ONE, 2014, 9 (07):
  • [5] Biomechanical comparison of different plating techniques in repair of mandibular angle fractures
    Alkan, Alper
    Celebi, Nukhet
    Ozden, Bora
    Bas, Burcn
    Inal, Samet
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (06): : 752 - 756
  • [6] A biomechanical comparison of new techniques for distal clavicular fracture repair versus locked plating
    Yagnik, Gautam P.
    Brady, Paul C.
    Zimmerman, Joseph P.
    Jordan, Charles J.
    Porter, David A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (05) : 982 - 988
  • [7] Comparison of two different ways to apply a circular plaster cast for distal radius fractures: biomechanical study
    Espejo-Reina, Alejandro
    Carrascal-Morillo, Maria T.
    Delgado-Martinez, Alberto D.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [8] Comparison of two different ways to apply a circular plaster cast for distal radius fractures: biomechanical study
    Alejandro Espejo-Reina
    María T. Carrascal-Morillo
    Alberto D. Delgado-Martínez
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [9] Cortical bone graft and endoprosthesis in the distal radius of dogs: A biomechanical comparison of two different limb-sparing techniques
    Liptak, JM
    Ehrhart, N
    Santoni, BG
    Wheeler, DL
    [J]. VETERINARY SURGERY, 2006, 35 (02) : 150 - 160
  • [10] Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture
    Cheng, Hsin-Yi Kathy
    Lin, Chun-Li
    Lin, Yu-Hao
    Chen, Alvin Chao-Yu
    [J]. CLINICAL BIOMECHANICS, 2007, 22 (05) : 510 - 517