RF Transmit/Receive Quadrature Fed Body Birdcage Coil for a 1.5T MR System

被引:0
|
作者
Yadav, Niraj S. [1 ]
Kochar, Inderkumar [1 ]
Bhuiya, Tapas K. [2 ]
Harsh, Rajesh [2 ]
机构
[1] St Francis Inst Technol, Dept EXTC, Mumbai, Maharashtra, India
[2] SAMEER, Technol Innovat Div, IIT Campus, Powai, India
关键词
Birdcage Coil; Magnetic Resonance Imaging (MRI); Nuclear Magnetic Resonance (NMR); RF Coil; Volume Coil; Quadrature feeding; FIELD MRI; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic Resonance Imaging (MRI) is an imaging technique which is used to view the inner part of the human body in a non-invasive manner. This imaging technique is based on the principle of Nuclear Magnetic Resonance (NMR). The Radio-frequency coil in MRI can be of various types. Birdcage Coil is a type of volume coil which is selected for the implementation of the RF coil due to better field homogeneity and high signal to noise ratio which in turn guarantees a large field of view. This paper describes the implementation of a strip based birdcage coil for a Human Body operating in high-pass, low-pass and band-pass modes. Since its introduction, determining the resonant modes has been a difficult task. This paper attempts to determine the resonant modes for high pass and band pass structures for a 1.5T MR System. The resonant frequency for a 1.5T MR system is 63.87 MHz which is obtained by the Larmor equation and is known as the Larmor frequency. The dimensions of the coil are kept constant for all the designs. The theoretical ideas were further validated in a computer simulation for all the three designs.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [1] Procedural Development of RF Tx/Rx Circularly Polarized Birdcage Coil at 1.5T MR system
    Patwardhan, Rutuja
    Sonawane, Shrikant
    Harsh, Rajesh
    Gaikwad, Sandeep
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, : 616 - 618
  • [2] Asymmetric quadrature split birdcage coil for hyperpolarized 3He lung MRI at 1.5T
    De Zanche, Nicola
    Chhina, Navjeet
    Teh, Kevin
    Randell, Chris
    Pruessmann, Klaas P.
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 431 - 438
  • [3] Saw-Tooth Shaped Legs Birdcage RF Coil for Small Animal NMR Imaging at 1.5T MRI System
    Kim, Jung-Min
    Ahmad, Sheikh Faisal
    Choi, Ick Chang
    Kim, Young Cheol
    Kim, Hyun Deok
    2013 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC 2013), 2013, : 542 - 544
  • [4] RF Heating Due to a 3 T Birdcage, Whole-body Transmit Coil in Anesthetized Sheep
    Turdumamatov, Samat
    Oto, Cagdas
    Algin, Oktay
    Erguder, Hamza
    Malas, Tahir
    EMAGRES, 2020, 9 (02): : 183 - 188
  • [5] An asymmetrical whole-body birdcage RF coil without RF shield for hyperpolarized 129Xe lung MR imaging at 1.5 T
    Puddu, Claudio
    Rao, Madhwesha
    Xu, Xiaojun
    Deppe, Martin H.
    Collier, Guilhem
    Maunder, Adam
    Chan, Ho-Fung
    De Zanche, Nicola
    Robb, Fraser
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3373 - 3381
  • [6] Whole-Body and Local RF Absorption in Human Models as a Function of Anatomy and Position within 1.5T MR Body Coil
    Murbach, Manuel
    Neufeld, Esra
    Kainz, Wolfgang
    Pruessmann, Klaas P.
    Kuster, Niels
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 839 - 845
  • [7] Design and Analysis of Four Channel Phased Array RF Coil for Spine scan using 1.5T MR System
    Asutkar, Neha
    Patil, Tejkiran
    Harsh, Rajesh
    Gaikwad, Sandeep
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, : 611 - 615
  • [8] A concept of volume wireless receive-only coil for 1.5T MRI
    Fedotov, Aleksandr
    Tikhonov, Pavel
    Puchnin, Viktor
    Brui, Ekaterina
    Levchuk, Anatoliy
    Karaeva, Ayshat
    Shchelokova, Alena
    Solomakha, Georgiy
    Hurshkainen, Anna
    JOURNAL OF MAGNETIC RESONANCE, 2025, 374
  • [9] Design Decoupling Methods of Multichannel Phased Array Receive Only RF Coil for Different Structures of 1.5T MRI
    Dapkar, Radhika
    Ugle, Niket
    Bagchi, Soumendu
    Bhuiya, Tapas
    Kulkarni, A. M.
    Gaikwad, Sandeep
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, : 606 - 610
  • [10] In vivo MR imaging using liquid nitrogen cooled phased array RF receiver coil at 1.5T
    Kwok, WE
    You, Z
    Zhong, J
    RADIOLOGY, 2002, 225 : 549 - 549