A state-of-the-art epithermal neutron irradiation facility for neutron capture therapy

被引:10
|
作者
Riley, KJ
Binns, PJ
Harling, OK
机构
[1] MIT, Nucl Reactor Lab, Cambridge, MA 02139 USA
[2] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 16期
关键词
D O I
10.1088/0031-9155/49/16/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At the Massachusetts Institute of Technology (MIT) the first fission converter-based epithermal neutron beam (FCB) has proven suitable for use in clinical trials of boron neutron capture therapy (BNCT). The modem facility provides a high intensity beam together with low levels of contamination that is ideally suited for use with future, more selective boron delivery agents. Prescriptions for normal tissue tolerance doses consist of 2 or 3 fields lasting less than 10 min each with the currently available beam intensity, that are administered with an automated beam monitoring and control system to help ensure safety of the patient and staff alike. A quality assurance program ensures proper functioning of all instrumentation and safety interlocks as well as constancy of beam output relative to routine calibrations. Beam line shutters and the medical room walls provide sufficient shielding to enable access and use of the facility without affecting other experiments or normal operation of the multipurpose research reactor at MIT. Medical expertise and a large population in the greater Boston area are situated conveniently close to the university, which operates the research reactor 24 It a day for approximately 300 days per year. The operational characteristics of the facility closely match those established for conventional radiotherapy, which together with a near optimum beam performance ensure that the FCB is capable of determining whether the radiobiological promise of NCT can be realized in routine practice.
引用
收藏
页码:3725 / 3735
页数:11
相关论文
共 50 条
  • [1] Study of epithermal neutron columns for boron neutron capture therapy
    Oka, Y
    Akiyama, M
    An, S
    PROGRESS IN NUCLEAR ENERGY, 1998, 32 (1-2) : 61 - 70
  • [2] Properties of a cold-neutron irradiation facility for in vitro research on boron neutron capture therapy at the Geesthacht Neutron Facility
    Lüdemann, L
    Kampmann, R
    Sosaat, W
    Staron, P
    Wille, P
    NUCLEAR SCIENCE AND ENGINEERING, 2000, 135 (01) : 57 - 63
  • [3] A DESIGN STUDY OF THE NEUTRON-IRRADIATION FACILITY FOR BORON NEUTRON-CAPTURE THERAPY
    OKA, Y
    YANAGISAWA, I
    AN, S
    NUCLEAR TECHNOLOGY, 1981, 55 (03) : 642 - 655
  • [4] A PROTOTYPE EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON-CAPTURE THERAPY
    NOONAN, DJ
    RUSSELL, JL
    BRUGGER, RM
    MEDICAL PHYSICS, 1986, 13 (02) : 211 - 216
  • [5] Status of epithermal neutron beam design for neutron capture therapy at THOR
    Liu, YWH
    Chu, HJ
    Liu, HM
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A363 - A366
  • [6] Development and characteristics of the HANARO neutron irradiation facility for applications in the boron neutron capture therapy field
    Kim, Myong-Seop
    Lee, Byung-Chul
    Hwang, Sung-Yul
    Kim, Heonil
    Jun, Byung-Jin
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09): : 2553 - 2566
  • [7] THICK BERYLLIUM TARGET AS AN EPITHERMAL NEUTRON SOURCE FOR NEUTRON-CAPTURE THERAPY
    WANG, CKC
    MOORE, BR
    MEDICAL PHYSICS, 1994, 21 (10) : 1633 - 1638
  • [8] ENHANCEMENT OF THE EPITHERMAL NEUTRON BEAM USED FOR BORON NEUTRON-CAPTURE THERAPY
    LIU, HYB
    BRUGGER, RM
    GREENBERG, DD
    RORER, DC
    HU, JP
    HAUPTMAN, HM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1149 - 1156
  • [9] Optimization of an accelerator-based epithermal neutron source for neutron capture therapy
    Kononov, OE
    Kononov, VN
    Bokhovko, MV
    Korobeynikov, VV
    Soloviev, A
    Sysoev, AS
    Gulidov, IA
    Chub, WT
    Nigg, DW
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1009 - 1013
  • [10] Epithermal neutron beam dosimetry with thermoluminescence dosemeters for boron neutron capture therapy
    Aschan, C
    Toivonen, M
    Savolainen, S
    Seppälä, T
    Auterinen, I
    RADIATION PROTECTION DOSIMETRY, 1999, 81 (01) : 47 - 56