Complications associated with secondary orbital implantations

被引:16
|
作者
Sundelin, Karin C.
Kopp, Eva M. E. Dafgard
机构
[1] Karolinska Inst, St Erik Eye Hosp, Oculoplast Serv, Stockholm, Sweden
[2] Karolinska Inst, St Erik Eye Hosp, Orbital Serv, Stockholm, Sweden
关键词
complication; exposure; infection; migration; orbit; reoperation; secondary implant; volume; INTRAORBITAL IMPLANTS; ENUCLEATION; MANAGEMENT; EXPOSURE;
D O I
10.1111/aos.12818
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate complications associated with secondary procedures for orbital implants. MethodsA retrospective review was made of the records of patients who had undergone a secondary orbital implantation at a tertiary referral centre at St Erik Eye Hospital in Stockholm, Sweden, from 1998 up to and including the first half of 2009. Implant-related complications were noted as was demographic and surgical background data. The regional ethics committee in Stockholm gave its approval for this study. ResultsSeventy-one patients had received a secondary orbital implant at the eye hospital. Implant-related complications were noted in 24 patients (34%), and 20 patients required reoperation/s (28%). There were five types of complications: migration of the implant (13%), insufficient orbital volume (10%), exposure/extrusion/infection (8%), mechanical obstruction (1%) and socket oedema (1%). Analyses of sizes and types of implants, wrapping and surgical techniques did not reveal any specific factor that resulted in an increased number of complications. However, there was an indication that aluminium oxide might be associated with fewer complications (2/11=18%). ConclusionOur results show that secondary orbital implantations have high complication rates and that further surgery is needed in more than a quarter of cases. It is important to consider these facts when planning to insert secondary implants and to provide patients with accurate information about the procedure and possible outcomes.
引用
收藏
页码:679 / 683
页数:5
相关论文
共 50 条
  • [1] COMPLICATIONS INVOLVING THE MAXILLARY SINUS SECONDARY TO IMPLANTATIONS
    SKOP, P
    SCHRAMMSCHERER, B
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1988, 43 (12): : 1348 - 1349
  • [2] Comparative study of modified and conventional secondary hydroxyapatite orbital implantations
    Zhao, Yong
    Zhang, Mao-Nian
    Gao, Yun-Xian
    Gao, Xiao-Wei
    Ren, Bing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (05) : 646 - 649
  • [3] Comparative study of modified and conventional secondary hydroxyapatite orbital implantations
    Yong Zhao
    Mao-Nian Zhang
    Yun-Xian Gao
    Xiao-Wei Gao
    Bing Ren
    International Journal of Ophthalmology, 2013, (05) : 646 - 649
  • [4] COMPLICATIONS OF PENILE IMPLANTATIONS
    Park, Jong Kwan
    JOURNAL OF SEXUAL MEDICINE, 2010, 7 : 75 - 76
  • [5] COMPLICATIONS OF BREAST IMPLANTATIONS
    GURDIN, M
    CARLIN, GA
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1967, 40 (06) : 530 - &
  • [6] ORBITAL COMPLICATIONS SECONDARY TO ENDOSCOPIC SINUS SURGERY
    NEUHAUS, RW
    OPHTHALMOLOGY, 1990, 97 (11) : 1512 - 1518
  • [7] Orbital and nasal complications secondary to inhaled cocaine abuse
    Contreras Molina, Purificacion
    Flores Carmona, Eva
    Munoz Palza, Carlos Alberto
    Tenor Serrano, Rafael Luis
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2012, 63 (03): : 233 - 236
  • [8] Complications associated with cardiac resynchronization therapy upgrades versus de novo implantations
    Sidhu, Baldeep S.
    Gould, Justin
    Sieniewicz, Benjamin J.
    Porter, Bradley
    Rinaldi, Christopher A.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2018, 16 (08) : 607 - 615
  • [10] COMPLICATIONS ASSOCIATED WITH ORBITAL BEAD IMPLANT OPERATION
    WALTER, WL
    OPHTHALMIC SURGERY AND LASERS, 1977, 8 (05): : 68 - 75