Integrated photonics interferometric interrogator for a ring-resonator ultrasound sensor

被引:3
|
作者
Ouyang, Boling [1 ]
Haverdings, Michael [2 ]
Horsten, Roland [1 ]
Kruidhof, Marten [1 ]
Kat, Pim [2 ]
Caro, Jacob [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Technobis Tft Fos, Pyrietstr 2, NL-1812 SC Alkmaar, Netherlands
关键词
INSULATOR MICRORING RESONATOR; SILICON; DESIGN; WDM;
D O I
10.1364/OE.27.023408
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a compact integrated photonics interrogator for a ring-resonator (RR) ultrasound sensor, the so-called MediGator. The MediGator consists of a special light source and an InP Mach-Zehnder interferometer (MZI) with a 3 x 3 multi-mode interferometer. Miniaturization of the MZI to chip size enables high temperature stability and negligible signal drift. The light source has a -3 dB bandwidth of 1.5 nm, a power density of 9 dBm/nm and a tuning range of 5.7 nm, providing sufficient signal level and robust alignment for the RR sensor. The mathematical procedure of interrogation is presented, leading to the optimum MZI design. We measure the frequency response of the sensor using the MediGator, giving a resonance frequency of 0.995 MHz. Further, high interrogation performance is demonstrated at the RR resonance frequency for an ultrasound pressure range of 1.47 - 442.4 Pa, which yields very good linearity between the pressure and the resulting modulation amplitude of the RR resonance wavelength. The measured signal time traces match well with calculated results. Linear fitting of the pressure data gives a sensor sensitivity of 77.2 fm/Pa. The MediGator provides a low detection limit, temperature robustness and a large measurement range for interrogating the RR ultrasound sensor. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License.
引用
收藏
页码:23408 / 23421
页数:14
相关论文
共 50 条
  • [1] Integrated optics ring-resonator chemical sensor with polymer transduction layer
    Ksendzov, A
    Homer, ML
    Manfreda, AM
    ELECTRONICS LETTERS, 2004, 40 (01) : 63 - 65
  • [2] Interrogation of a ring-resonator ultrasound sensor using a fiber Mach-Zehnder interferometer
    Peternella, Fellipe Grillo
    Ouyang, Boling
    Horsten, Roland
    Haverdings, Michael
    Kat, Pim
    Caro, Jacob
    OPTICS EXPRESS, 2017, 25 (25): : 31622 - 31639
  • [3] Polymer ring-resonator on a slotted membrane for ultrasound imaging
    Sahraeibelverdi, T.
    Veladi, H.
    Shirazi, A.
    Malekshahi, M.
    OPTICAL MODELING AND PERFORMANCE PREDICTIONS XII, 2022, 12215
  • [4] Integrated optics ring-resonator sensors for protein detection
    Ksendzov, A
    Lin, Y
    OPTICS LETTERS, 2005, 30 (24) : 3344 - 3346
  • [5] INTEGRATED OPTICAL RING-RESONATOR WITH MICROMECHANICAL DIAPHRAGM FOR PRESSURE SENSING
    DEBRABANDER, GN
    BOYD, JT
    BEHEIM, G
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1994, 6 (05) : 671 - 673
  • [6] Mode converter based on ring resonator for integrated photonics
    Kutluyarov, Ruslan, V
    Lyubopytov, Vladimir S.
    Fatkhiev, Denis M.
    Sultanov, Albert Kh
    OPTICAL TECHNOLOGIES FOR TELECOMMUNICATIONS 2019, 2020, 11516
  • [7] ACCELERATING SYSTEMS WITH RING-RESONATOR CONFIGURATION
    SPECIALE, RA
    NUCLEAR INSTRUMENTS & METHODS, 1967, 55 (02): : 205 - &
  • [8] COMPOUND FIBER RING-RESONATOR - THEORY
    ZHANG, JL
    LIT, JWY
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (06) : 1867 - 1873
  • [9] Integrated optical ring-resonator gyro using silica Planar Lightwave Circuit
    Suzuki, K
    Takiguchi, K
    Hotate, K
    FIBER OPTIC AND LASER SENSORS AND APPLICATIONS: INCLUDING DISTRIBUTED AND MULTIPLEXED FIBER OPTIC SENSORS VII, 1999, 3541 : 66 - 75
  • [10] MICROSTRIP MODE SUPPRESSION RING-RESONATOR
    CARROLL, JM
    CHANG, K
    ELECTRONICS LETTERS, 1994, 30 (22) : 1861 - 1862