Prospective observational study on diagnostic accuracy of whole-body MRI in solid small round cell tumours

被引:14
|
作者
Kembhavi, S. A. [1 ]
Rangarajan, V. [2 ]
Shah, S. [2 ]
Qureshi, S. [3 ]
Arora, B. [4 ]
Juvekar, S. [1 ]
Laskar, S. [5 ]
Vora, T. [4 ]
Chinnaswamy, G. [4 ]
Ramadwar, M. [6 ]
Kurkure, P. [4 ]
机构
[1] Tata Mem Hosp, Dept Radiodiag, Bombay 400012, Maharashtra, India
[2] Tata Mem Hosp, Bioimaging Unit, Bombay 400012, Maharashtra, India
[3] Tata Mem Hosp, Dept Surg, Bombay 400012, Maharashtra, India
[4] Tata Mem Hosp, Dept Med Oncol, Bombay 400012, Maharashtra, India
[5] Tata Mem Hosp, Dept Radiotherapy, Bombay 400012, Maharashtra, India
[6] Tata Mem Hosp, Dept Pathol, Bombay 400012, Maharashtra, India
关键词
PEDIATRIC-PATIENTS; SKELETAL SCINTIGRAPHY; BONE METASTASES; CHILDREN; NEOPLASMS; PET/CT; CT;
D O I
10.1016/j.crad.2014.04.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess the diagnostic accuracy of whole-body magnetic resonance imaging (WB-MRI) for metastatic disease in patients with solid small round cell tumours (SRCT) by comparing it with routine staging procedures (standard of care). MATERIALS AND METHODS: Eligible cases of neuroblastoma, primitive neuroectodermal tumour, and rhabdomyosarcoma were enrolled in the study after obtaining informed consent. WB-MRI was undertaken using overlapping coronal T1 and short-tau inversion recovery (STIR) sequences. Lesions were classified into skeletal, pulmonary, and soft-tissue types. Conventional staging, which consisted of combined positron-emission tomography & computed tomography (PET-CT), bone scintigraphy & bone marrow biopsy for bone metastases, CT thorax for lung metastases, combined PET-CT, metaiodobenzylguanidine (MIBG) scintigraphy (in neuroblastoma) for soft tissue metastases and clinical evaluation was used as the reference standard. Parameters for diagnostic accuracy were calculated. RESULTS: Thirty-four out of forty patients enrolled were included in final analysis, half of them having metastatic disease. The sensitivity, specificity, positive and negative predictive value, and the diagnostic accuracy of WB-MRI and PET-CT for skeletal metastases as compared to reference standard were 91.9%, 99.8%, 97.4%, 99.6%, and 95.5% and 99.1%, 99.9%, 99.1%, 99.9%, and 99.9%, respectively. The sensitivity of MRI, only PET and PET-CT with plain CT thorax was 30%, 40%, and 100%, respectively, for lung metastases. The sensitivity of MRI for soft-tissue lesions was 76.9%. CONCLUSION: WB-MRI is a radiation-free tool with high diagnostic accuracy for the evaluation of metastatic disease to the marrow. The rate of detection of soft-tissue metastases, such as nodal metastases, is less when WB-MRI is compared with conventional staging using coronal STIR images. CT thorax is essential for accurate evaluation of lung metastases. (C) 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:900 / 908
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Philipp Heusch
    Felix Nensa
    Benedikt Schaarschmidt
    Rupika Sivanesapillai
    Karsten Beiderwellen
    Benedikt Gomez
    Jens Köhler
    Henning Reis
    Verena Ruhlmann
    Christian Buchbender
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 42 - 48
  • [2] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Heusch, Philipp
    Nensa, Felix
    Schaarschmidt, Benedikt
    Sivanesapillai, Rupika
    Beiderwellen, Karsten
    Gomez, Benedikt
    Koehler, Jens
    Reis, Henning
    Ruhlmann, Verena
    Buchbender, Christian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (01) : 42 - 48
  • [3] Diagnostic accuracy of whole-body MRI/DWI image fusion for detection of malignant tumours: a comparison with PET/CT
    Michael A. Fischer
    Daniel Nanz
    Thomas Hany
    Caecilia S. Reiner
    Paul Stolzmann
    Olivio F. Donati
    Stefan Breitenstein
    Paul Schneider
    Dominik Weishaupt
    Gustav K. von Schulthess
    Hans Scheffel
    European Radiology, 2011, 21 : 246 - 255
  • [4] Diagnostic accuracy of whole-body MRI/DWI image fusion for detection of malignant tumours: a comparison with PET/CT
    Fischer, Michael A.
    Nanz, Daniel
    Hany, Thomas
    Reiner, Caecilia S.
    Stolzmann, Paul
    Donati, Olivio F.
    Breitenstein, Stefan
    Schneider, Paul
    Weishaupt, Dominik
    von Schulthess, Gustav K.
    Scheffel, Hans
    EUROPEAN RADIOLOGY, 2011, 21 (02) : 246 - 255
  • [5] Comparison of the diagnostic accuracy of whole-body MRI and whole-body CT in stage III/IV malignant melanoma
    Hausmann, Daniel
    Jochum, Susanne
    Utikal, Jochen
    Hoffmann, Richard Christian
    Zechmann, Christian
    Neff, Kurt Wolfgang
    Goerdt, Sergij
    Schoenberg, Stefan Oswald
    Dinter, Dietmar Joerg
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2011, 9 (03): : 212 - 221
  • [6] Diagnostic accuracy of whole-body MRI versus standard imaging pathways for metastatic disease in newly diagnosed non-small-cell lung cancer: the prospective Streamline L trial
    Taylor, Stuart A.
    Mallett, Sue
    Ball, Simon
    Beare, Sandy
    Bhatnagar, Gauraang
    Bhowmik, Angshu
    Boavida, Peter
    Bridgewater, John
    Clarke, Caroline S.
    Duggan, Marian
    Ellis, Steve
    Glynne-Jones, Robert
    Goh, Vicky
    Groves, Ashley M.
    Hameeduddin, Ayshea
    Janes, Sam M.
    Johnston, Edward W.
    Koh, Dow-Mu
    Lock, Sara
    Miles, Anne
    Morris, Stephen
    Morton, Alison
    Navani, Neal
    Oliver, Alfred
    O'Shaughnessy, Terry
    Padhani, Anwar R.
    Prezzi, David
    Punwani, Shonit
    Quinn, Laura
    Rafiee, Hameed
    Reczko, Krystyna
    Rockall, Andrea G.
    Russell, Peter
    Sidhu, Harbir S.
    Strickland, Nicola
    Tarver, Kathryn
    Teague, Jonathan
    Halligan, Steve
    LANCET RESPIRATORY MEDICINE, 2019, 7 (06): : 523 - 532
  • [7] Feasibility and diagnostic accuracy of fast whole-body MRI in slightly to moderately injured trauma patients
    Reichel, Katrin
    Hahlbohm, Patricia
    Kromrey, Marie-Luise
    Nebelung, Heiner
    Schoen, Felix
    Kamin, Konrad
    Goronzy, Jens
    Kuehn, Jens-Peter
    Hoffmann, Ralf-Thorsten
    Blum, Sophia Freya Ulrike
    EUROPEAN RADIOLOGY, 2025, 35 (01) : 487 - 495
  • [8] Accuracy of whole-body MRI in the assessment of splenic involvement in lymphoma
    Littooij, Annemieke S.
    Kwee, Thomas C.
    Barber, Ignasi
    Granata, Claudio
    de Keizer, Bart
    Beek, Frederik J. A.
    Hobbelink, Monique G.
    Fijnheer, Rob
    Stoker, Jaap
    Nievelstein, Rutger A. J.
    ACTA RADIOLOGICA, 2016, 57 (02) : 142 - 151
  • [9] Whole-body MRI in the Study of Health in Pomerania
    Puls, R.
    Voelzke, H.
    RADIOLOGE, 2011, 51 (05): : 379 - 383
  • [10] A prospective study determining and comparing the diagnostic accuracy of fluoride-PET/CT, choline-PET/CT, whole-body bone SPECT/CT and whole-body MRI for the detection of bone metastases in patients with prostate cancer
    Dyrberg E.
    Hendel H.W.
    Løgager V.B.
    Madsen C.
    Pedersen E.M.
    Zerahn B.
    Thomsen H.S.
    European Journal of Hybrid Imaging, 2 (1):