Triple-hot-film anemometer performance in CASES-99 and a comparison with sonic anemometer measurements

被引:19
|
作者
Skelly, BT [1 ]
Miller, DR [1 ]
Meyer, TH [1 ]
机构
[1] Univ Connecticut, Dept Nat Resources Management & Engn, Storrs, CT 06269 USA
基金
美国国家科学基金会;
关键词
CASES-99; friction velocity; sensible heat flux; sonic anemometer; triple-hot-film anemometer; turbulent kinetic energy;
D O I
10.1023/A:1019906521898
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Two levels of triple-hot-film and sonic anemometers were deployed on a 5.5-m tower during the Cooperative Atmospheric Surface Exchange Study (CASES-99) in October 1999. Each triple-hot-film probe was collocated 50 mm from the sonic sensing path on a common boom. Various problems with using triple-hot-films in the atmosphere to resolve wind components are addressed including the derivation of a yaw angle correction using the collocated sensors. It was found that output voltage drift due to changes in environmental temperature could be monitored and corrected using an automated system. Non-unique solutions to heat transfer equations can be resolved using a collocated sonic anemometer. Multi-resolution decomposition of the hot-film data was used to estimate appropriate day and night averaging periods for turbulent flux measurements in and near the roughness sub-layer. Finally, triple-hot-film measurements of mean wind magnitude (M), turbulent kinetic energy (TKE), sensible heat flux (H), and local friction velocity (u(*)) are compared to those of the collocated CSAT3 sonic anemometers. Overall, the mean wind magnitudes measured by the triple-hot-film and the collocated sonic sensors were close, consistent and independent of stability or proximity to the ground. The turbulent statistics, TKE, u(*), and H, measured by the two sensor systems were reasonably close together at z = 5 m. However, the ratio of sonic measurement/hot-film measurement decreased toward the ground surface, especially during stable conditions.
引用
收藏
页码:275 / 304
页数:30
相关论文
共 31 条
  • [1] Triple-Hot-Film Anemometer Performance in Cases-99 and A Comparison With Sonic Anemometer Measurements
    Brian T. Skelly
    David R. Miller
    Thomas H. Meyer
    Boundary-Layer Meteorology, 2002, 105 : 275 - 304
  • [2] Comparison of sonic anemometer performance under foggy conditions
    El-Madany, Tarek S.
    Griessbaum, F.
    Fratini, G.
    Juang, J. -Y.
    Chang, S. -C.
    Klemm, O.
    AGRICULTURAL AND FOREST METEOROLOGY, 2013, 173 : 63 - 73
  • [3] HOT-FILM ANEMOMETER MEASUREMENTS IN A STARTING TURBULENT JET
    WITZE, PO
    AIAA JOURNAL, 1983, 21 (02) : 308 - 309
  • [4] COMPARISON OF VELOCITY SPECTRA FROM HOT-FILM ANEMOMETER AND GUST-PROBE MEASUREMENTS
    MOSS, MS
    MERCERET, FJ
    JOURNAL OF APPLIED METEOROLOGY, 1977, 16 (03): : 319 - 320
  • [5] Methods based on one component Laser Doppler Anemometer and Hot Film Anemometer for three dimensional turbulent measurements.
    Zeris, AP
    Optical Measurement Systems for Industrial Inspection IV, Pts 1 and 2, 2005, 5856 : 874 - 881
  • [6] HOT-FILM ANEMOMETER MEASUREMENTS OF VELOCITY DECAY IN KARMAN TRAIL VORTEXES
    WILKINS, EM
    JOURNAL OF GEOPHYSICAL RESEARCH, 1970, 75 (06): : 1033 - &
  • [7] HOT-FILM ANEMOMETER VELOCITY-MEASUREMENTS OF ARTERIAL FLOW IN HORSES
    NEREM, RM
    RUMBERGE.JA
    GROSS, DR
    HAMLIN, RL
    GEIGER, GL
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 379 - 379
  • [8] HOT-FILM ANEMOMETER VELOCITY-MEASUREMENTS OF ARTERIAL FLOW IN HORSES
    NEREM, RM
    RUMBERGE.JA
    GROSS, DR
    HAMLIN, RL
    GEIGER, GL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (11): : 1486 - 1486
  • [9] Flexible Hot-film Anemometer Arrays for Flow Measurements on Curved Structures
    Beutel, T.
    Schwerter, M.
    Leester-Schaedel, M.
    Dietzel, A.
    Buettgenbach, S.
    SMART SENSORS, ACTUATORS, AND MEMS VI, 2013, 8763
  • [10] COMPARISON OF SURFACE WIND STRESS MEASUREMENTS - AIRBORNE RADAR SCATTEROMETER VERSUS SONIC ANEMOMETER
    BRUCKS, JT
    JONES, WL
    LEMING, TD
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1980, 85 (NC9) : 4967 - 4976