D-Dimer test and diagnosis of deep vein thrombosis: A comparative study of 7 assays

被引:0
|
作者
Elias, A
Aptel, I
Huc, B
Chale, JJ
Nguyen, F
Cambus, JP
Boccalon, H
Boneu, B
机构
[1] HOP PURPAN,LAB RECH HEMOSTASE & THROMBOSE,F-31059 TOULOUSE,FRANCE
[2] HOP RANGUEIL,SERV ANGIOL,TOULOUSE,FRANCE
[3] FAC MED TOULOUSE,DEPT EPIDEMIOL ECON SANTE & SANTE COMMUNAUTAIRE,TOULOUSE,FRANCE
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The current D-Dimer ELISA methods provide high sensitivity and negative predictive value for the diagnosis of deep vein thrombosis but these methods are not suitable for emergency or for individual determination. We have evaluated the performance of 3 newly available fast D-Dimer assays (Vidas D-Di, BioMerieux; Instant IA D-Di, Stage; Nycocard D-Dimer, Nycomed) in comparison with 3 classic ELISA methods (Stage, Organon, Behring) and a Latex agglutination technique (Stage). One-hundred-and-seventy-one patients suspected of presenting a first episode of deep vein thrombosis were investigated. A deep vein thrombosis was detected in 75 patients (43.8%) by ultrasonic duplex scanning of the lower limbs; in 11 of them the thrombi were distal and very limited in size (<2 cm). We compared the performance of the tests by calculating their sensitivity, specificity, positive and negative predictive value for different cut-off levels and by calculating the area under ROC curves. The concordance of the different methods was evaluated by calculating the kappa coefficient. The performances of the 3 classic ELISA and of the Vidas D-Di were comparable and kappa coefficients indicated a good concordance between the results provided by these assays. Their sensitivity slightly declined for detection of the very small thrombi. Instant IA D-Di had a non-significantly lower sensitivity and negative predictive value than the 4 previous assays; however its performance was excellent for out-patients. As expected, the Latex assay had too low a sensitivity and negative predictive value to be recommended. In our hands, Nycocard D-Dimer also exhibited low sensitivity and negative predictive value, which were significantly improved when the plasma samples were tested by the manufacturer, Thus significant progress has been made, allowing clinical studies to be planned to compare the safety and cost-effectiveness of D-Dimer strategy to those of the conventional methods for the diagnosis of venous thrombosis.
引用
收藏
页码:518 / 522
页数:5
相关论文
共 50 条
  • [1] ASSESSMENT OF D-DIMER ASSAYS FOR THE DIAGNOSIS OF DEEP-VEIN THROMBOSIS
    HEATON, DC
    BILLINGS, JD
    HICKTON, CM
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1987, 110 (05): : 588 - 591
  • [2] D-dimer test in deep vein thrombosis
    Chow, KM
    Wong, RSM
    Cheng, G
    JOURNAL OF INTERNAL MEDICINE, 2002, 252 (06) : 575 - 575
  • [3] Validity of D-dimer tests in the diagnosis of deep vein thrombosis: a prospective comparative study of three quantitative assays
    Larsen, TB
    Stoffersen, E
    Christensen, CS
    Laursen, B
    JOURNAL OF INTERNAL MEDICINE, 2002, 252 (01) : 36 - 40
  • [4] D-dimer test in deep vein thrombosis - Reply
    Larsen, TB
    Laursen, B
    JOURNAL OF INTERNAL MEDICINE, 2002, 252 (06) : 576 - 576
  • [5] Plasma D-dimer in the diagnosis of deep vein thrombosis
    Lippi, G
    Mengoni, A
    Manzato, F
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (21): : 1828 - 1829
  • [6] Clinical pre test probability and D-dimer in the diagnosis of deep vein thrombosis
    Crippa, L
    Tomassini, L
    Rizzi, B
    Pattarini, E
    DAlessandro, G
    Vigano, S
    THROMBOSIS AND HAEMOSTASIS, 1997, : PD647 - PD647
  • [7] An evaluation of rapid D-dimer assays for the exclusion of deep vein thrombosis
    Gardiner, C
    Pennaneac'h, C
    Walford, C
    Machin, SJ
    Mackie, IJ
    BRITISH JOURNAL OF HAEMATOLOGY, 2005, 128 (06) : 842 - 848
  • [8] Plasma D-dimer in the diagnosis of deep vein thrombosis - Reply
    Anand, SS
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (21): : 1829 - 1829
  • [9] Comparative study of four new and rapid D-Dimer assays to exclude deep vein thrombosis or pulmonary embolism
    Breton, E
    LeQuerrec, A
    Lechevalier, B
    Creveuil, C
    Gautier, P
    BorelDerlon, A
    THROMBOSIS AND HAEMOSTASIS, 1997, : PS168 - PS168
  • [10] VALUE OF D-DIMER ASSAYS IN THE EMERGENCY DIAGNOSIS OF DEEP VENOUS THROMBOSIS
    MOSSAZ, A
    GANDRILLE, S
    VITOUX, JF
    ABDOUCHELIBAUDOT, N
    AIACH, M
    FIESSINGER, JN
    PRESSE MEDICALE, 1990, 19 (22): : 1055 - 1055