High-bandwidth scanned-wavelength-modulation spectroscopy sensors for temperature and H2O in a rotating detonation engine

被引:61
|
作者
Goldenstein, Christopher S. [1 ]
Almodovar, Christopher A. [1 ]
Jeffries, Jay B. [1 ]
Hanson, Ronald K. [1 ]
Brophy, Christopher M. [2 ]
机构
[1] Stanford Univ, High Temp Gasdynam Lab, Stanford, CA 94305 USA
[2] Naval Postgrad Sch, Dept Mech & Aerosp Engn, Monterey, CA 93943 USA
关键词
wavelength-modulation spectroscopy; tunable diode laser absorption spectroscopy; molecular spectroscopy; combustion; detonations; LASER ABSORPTION SENSOR; DIODE-LASER; RAPID MEASUREMENTS; GAS TEMPERATURE; WATER-VAPOR; PRESSURE; PARAMETERS;
D O I
10.1088/0957-0233/25/10/105104
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The design and use of two-color tunable diode laser (TDL) absorption sensors for measurements of temperature and H2O in a rotating detonation engine (RDE) are presented. Both sensors used first-harmonic-normalized scanned-wavelength-modulation spectroscopy with second-harmonic detection (scanned-WMS-2f/1f) to account for non-absorbing transmission losses and emission encountered in the harsh combustion environment. One sensor used two near-infrared (NIR) TDLs near 1391.7 nm and 1469.3 nm that were modulated at 225 kHz and 285 kHz, respectively, and sinusoidally scanned across the peak of their respective H2O absorption transitions to provide a measurement rate of 50 kHz and a detection limit in the RDE of 0.2% H2O by mole. The other sensor used two mid-infrared (MIR) TDLs near 2551 nm and 2482 nm that were modulated at 90 kHz and 112 kHz, respectively, and sinusoidally scanned across the peak of their respective H2O transitions to provide a measurement rate of 10 kHz and a detection limit in the RDE of 0.02% H2O by mole. Four H2O absorption transitions with different lower-state energies were used to assess the homogeneity of temperature in the measurement plane. Experimentally derived spectroscopic parameters that enable temperature and H2O sensing to within 1.5-3.5% of known values are reported. The sensor design enabling the high-bandwidth scanned-WMS-2f/1f measurements is presented. The two sensors were deployed across two orthogonal and coplanar lines-of-sight (LOS) located in the throat of a converging-diverging nozzle at the RDE combustor exit. Measurements in the non-premixed H-2-fueled RDE indicate that the temperature and H2O oscillate at the detonation frequency (approximate to 3.25 kHz) and that production of H2O is a weak function of global equivalence ratio.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] High-bandwidth absorption-spectroscopy measurements of temperature, pressure, CO, and H2O in the annulus of a rotating detonation rocket engine
    Mathews, Garrett C.
    Blaisdell, Matthew G.
    Lemcherfi, Aaron, I
    Slabaugh, Carson D.
    Goldenstein, Christopher S.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2021, 127 (12):
  • [2] A scanned-wavelength-modulation absorption-spectroscopy sensor for temperature and H2O in low-pressure flames
    Smith, Colin H.
    Goldenstein, Christopher S.
    Hanson, Ronald K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (11)
  • [3] Scanned-wavelength-modulation spectroscopy near 2.5 μm for H2O and temperature in a hydrocarbon-fueled scramjet combustor
    Goldenstein, C. S.
    Schultz, I. A.
    Spearrin, R. M.
    Jeffries, J. B.
    Hanson, R. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 116 (03): : 717 - 727
  • [4] Scanned-wavelength-modulation spectroscopy near 2.5 μm for H2O and temperature in a hydrocarbon-fueled scramjet combustor
    C. S. Goldenstein
    I. A. Schultz
    R. M. Spearrin
    J. B. Jeffries
    R. K. Hanson
    Applied Physics B, 2014, 116 : 717 - 727
  • [5] Near-MHz temperature and H2O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy
    Schwartz, Charles J.
    Stiborek, Joshua W.
    Butler, Austin
    Chen, Damon
    Guildenbecher, Daniel R.
    Welliver, Marc
    Glumac, Nick
    Goldenstein, Christopher S.
    APPLIED OPTICS, 2023, 62 (06) : 1598 - 1609
  • [6] Near-GHz scanned-wavelength-modulation spectroscopy for MHz thermometry and H2O measurements in aluminized fireballs of energetic materials
    Mathews, Garrett
    Goldenstein, Christopher
    APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (11):
  • [7] Calibration-free scanned wavelength modulation spectroscopy-application to H2O and temperature sensing in flames
    Qu, Zhechao
    Ghorbani, Ramin
    Valiev, Damir
    Schmidt, Florian M.
    OPTICS EXPRESS, 2015, 23 (12): : 16492 - 16499
  • [8] Wavelength-modulation spectroscopy near 2.5 μm for H2O and temperature in high-pressure and -temperature gases
    Goldenstein, C. S.
    Spearrin, R. M.
    Jeffries, J. B.
    Hanson, R. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 116 (03): : 705 - 716
  • [9] Wavelength-Modulation Spectroscopy for Measurements of Gas Pressure, Temperature and H2O Concentration in High-Temperature Environment
    Qu Dong-sheng
    Hong Yan-ji
    Wang Guang-yu
    Pan Hu
    Wang Ming-dong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (05) : 1339 - 1344
  • [10] Wavelength-modulation spectroscopy near 2.5 μm for H2O and temperature in high-pressure and -temperature gases
    C. S. Goldenstein
    R. M. Spearrin
    J. B. Jeffries
    R. K. Hanson
    Applied Physics B, 2014, 116 : 705 - 716