Cine magnetic resonance imaging study of blood flow and wall motion of the aortic arch

被引:0
|
作者
Yoshii, S [1 ]
Mohri, N [1 ]
Kamiya, K [1 ]
Tada, Y [1 ]
机构
[1] YAMANASHI MED UNIV,DEPT SURG,TAMAHO,YAMANASHI,JAPAN
来源
关键词
aortic arch movement; turbulence of the arch flow; cine MR imaging study;
D O I
暂无
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
The aortic arch has 3D distortions in the transverse arch in the axial view, and we previously reported that this distortion is a risk factor in the pathogenesis of arch aneurysms. In this study, we evaluated blood flow and movement of the aortic arch. In 10 healthy young volunteers, ECG-gated cine magnetic resonance imaging was carried out in the axial plane of the transverse arch, the coronal plane of the ascending arch, and the long axial plane along the entire arch. 1. Left anterolateral movements around the midpoint of the transverse arch in the systolic phase were observed in all of the men (6.3+/-1.59 mm) and women (4.8+/-0.73 mm). 2. A jet flow was detected in the systolic phase along the right side of the aortic wall. At the top of the plane, this jet flow turned to the left in a clockwise rotation in the anterior view. 3. In the long axial plane, a turbulent flow in the systolic phase was observed distal to the left subclavian arterial orifice in 6 of the 7 cases. In conclusion, this turbulent flow and left anterolateral wall motion of the transverse arch are due to anatomical three-dimensional distortion of the transverse arch. We propose that these phenomena may be important risk factors in the pathogenesis of arch aneurysms.
引用
收藏
页码:553 / 559
页数:7
相关论文
共 50 条
  • [1] OBLIQUE CINE MAGNETIC-RESONANCE BLOOD-FLOW IMAGING TO ASSESS CHANGES IN WALL MOTION
    ASKENASE, A
    CHEN, G
    THOMPSON, W
    ISKANDRIAN, AS
    HEO, J
    HELFANT, RH
    CIRCULATION, 1987, 76 (04) : 29 - 29
  • [2] BLOOD-FLOW IMAGING BY CINE MAGNETIC-RESONANCE
    NAYLER, GL
    FIRMIN, DN
    LONGMORE, DB
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 715 - 722
  • [3] QUANTIFICATION AND CINE MAGNETIC-RESONANCE-IMAGING OF THE HUMAN BLOOD-FLOW
    BOESIGER, P
    MEIER, D
    MAIER, SE
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 512 - 513
  • [4] Blood flow measured by magnetic resonance imaging at rest and exercise after surgical bypass of aortic arch obstruction
    Pedersen, Lia Mendes
    Pedersen, Thais Almeida Lins
    Pedersen, Erik Morre
    Hojmyr, Hilde
    Emmertsen, Kristian
    Hjortdal, Vibeke Etisabeth
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 37 (03) : 658 - 661
  • [5] Double aortic arch diagnosed by magnetic resonance imaging
    Lotz, J
    Macchiarini, P
    NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (22): : E20 - E20
  • [6] Cine Phase-Contrast Magnetic Resonance Imaging for the Measurement of Renal Blood Flow
    Prowle, John R.
    Molan, Maurice P.
    Hornsey, Emma
    Bellomo, Rinaldo
    CARDIORENAL SYNDROMES IN CRITICAL CARE, 2010, 165 : 329 - 336
  • [7] ANALYSIS OF BLOOD-FLOW PATTERNS IN AORTIC-ANEURYSM BY CINE MAGNETIC-RESONANCE-IMAGING - A REVIEW OF CASE MATERIAL
    MATSUOKA, H
    SHIGEMATSU, Y
    OHTANI, T
    SUMIMOTO, T
    HAMADA, M
    HIWADA, K
    MIKI, H
    SADAMOTO, K
    ANGIOLOGY, 1992, 43 (03) : 181 - 187
  • [8] Cardiac Motion Analysis from Magnetic Resonance Imaging: Cine Magnetic Resonance versus Tagged Magnetic Resonance
    Bajo, A.
    Ledesma-Carbayo, M. J.
    Marta, C. Santa
    David, E. Perez
    Garcia-Fernandez, M. A.
    Desco, M.
    Santos, A.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 81 - +
  • [9] DEMONSTRATION OF AORTIC LESIONS VIA CINE MAGNETIC-RESONANCE-IMAGING
    SONNABEND, SB
    COLLETTI, PM
    PENTECOST, MJ
    MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 613 - 618
  • [10] EVALUATION OF AORTIC REGURGITATION USING CINE MAGNETIC-RESONANCE-IMAGING
    TAMAI, T
    KONISHI, T
    OKAMOTO, S
    SAKUMA, H
    TAKEDA, K
    NAKANO, T