Three-year results of proximal tibia fractures treated with the LISS

被引:43
|
作者
Boldin, Christian [1 ]
Fankhauser, Florian [1 ]
Hofer, Herwig Peter [1 ]
Szyszkowitz, Rudolf [1 ]
机构
[1] Med Univ, Dept Trauma Surg, Graz, Austria
关键词
D O I
10.1097/01.blo.0000203467.58431.a0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Proximal tibia fractures present a difficult treatment challenge with historically high complication rates. In a prospective study, we asked whether the Less Invasive Stabilization System (LISS) plate can adequately treat extraarticular and complex intraarticular proximal tibia fractures and provide low complication rates and acceptable long-term functional outcomes. We prospectively observed 25 patients with 26 proximal tibia fractures (AO type A2, A3, C1, C2, or C3) treated with the LISS. Consecutive 3-year followup included radiographs and clinical examinations using Knee Society scores and Hospital for Special Surgery scores for extraarticular and intraarticular fractures. No loss of reduction occurred in patients with extraarticular fractures, whereas varus malalignment occurred in one patient with an intraarticular fracture. Two patients with AO 41 C 3.3 fractures had severe knee arthrosis develop and had total knee replacements. The mean Knee Society scores and final average Hospital for Special Surgery scores were similar for extraarticular and intraarticular fractures. Complications related to the surgery included one delayed union and implant removal in two patients. The LISS provided stable fixation of extraarticular and intraarticular proximal tibia fractures and good functional outcomes with a low complication rate. In complex articular fractures additional screws should be used.
引用
收藏
页码:222 / 229
页数:8
相关论文
共 50 条
  • [1] Closed fractures of the proximal tibia treated with a functional brace
    Martinez, A
    Sarmiento, A
    Latta, LL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) : 293 - 302
  • [2] Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: indications, surgical technique and preliminary results of the UMC clinical trial
    Cole, PA
    Zlowodzki, M
    Kregor, PJ
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : S16 - S29
  • [3] LISS-Tractor. Combination of the less invasive stabilization system (LISS) with the AO distractor for fractures of the distal femur and proximal tibia
    Babst, R
    Hehli, M
    Regazzoni, P
    UNFALLCHIRURG, 2001, 104 (06): : 530 - 535
  • [4] Epiphyseal fractures of the proximal tibia
    Rhemrev, SJ
    Sleeboom, C
    Ekkelkamp, S
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (03): : 131 - 134
  • [5] FATIGUE FRACTURES OF PROXIMAL TIBIA
    KIMBALL, PR
    SAVASTAN.AA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1970, (70) : 170 - &
  • [6] Partial proximal tibia fractures
    Raschke, Michael J.
    Kittl, Christoph
    Domnick, Christoph
    EFORT OPEN REVIEWS, 2017, 2 (05): : 241 - 249
  • [7] EPIPHYSEAL FRACTURES OF THE PROXIMAL TIBIA
    POULSEN, TD
    SKAK, SV
    JENSEN, TT
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1989, 20 (02): : 111 - 113
  • [8] Proximal Tibia Fractures in Osteoporosis
    Ravi Sauhta
    Dheeraj Makkar
    Indian Journal of Orthopaedics, 2025, 59 (3) : 326 - 345
  • [9] Intramedullary headless screw fixation for fractures of the proximal phalanges of the hand: a three-year follow-up
    Nietlispach, Viviane
    Besmens, Inga S.
    Medina Gontier, Julie
    Laber, Raffael
    Frauenfelder, Thomas
    Calcagni, Maurizio
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 2024, 47 (01)
  • [10] Results of a three-year hospitalist intervention.
    Palmer, H
    Armistead, N
    Manivannan, S
    Shockcor, WT
    Hobbs, G
    Evans, K
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2002, 17 : 139 - 139