Quantification of estrogens in infant formulas by isotope dilution liquid chromatography-tandem mass spectrometry

被引:4
|
作者
Liu, Shuan [1 ,2 ]
Li, Xiaomin [2 ]
Zhao, Yingchen [2 ]
Yin, Xiong [1 ]
Zhang, Qinghe [2 ]
Li, Xiuqin [2 ]
Tang, Guangshi [1 ]
Li, Hongmei [2 ]
机构
[1] Beijing Univ Chem Technol, Sch Sci, State Key Lab Chem Resource Engn, Beijing 100029, Peoples R China
[2] Natl Inst Metrol, Div Metrol Chem, Lab Food Safety, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
GAS-CHROMATOGRAPHY; BREAST-MILK; 17-BETA-ESTRADIOL; EXTRACTION; FOOD; COWS; DIETHYLSTILBESTROL; IMMUNOASSAY; METABOLITES; SUBSTANCES;
D O I
10.1039/c8ay01101j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Steroid estrogens, such as estrone (E1), 17-estradiol (E2) and estriol (E3), have been shown to exhibit potentially adverse effects on the health of children. Consequently, it is highly desirable to develop detection approaches for rapid and accurate determination of steroid estrogens in infant formulas. In this study, a robust method based on isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) was developed to simultaneously measure E1, E2 and E3 in infant formulas with no need for any derivatization step. The desired simplicity, accuracy and specificity were achieved via a facile sample pretreatment process, including protein precipitation and clean-up steps. The limits of quantification were 0.0025, 0.005 and 0.005 g kg(-1) for E1, E2 and E3, respectively. Besides, a recovery of 92.3-102.7% was obtained with a relative standard deviation of less than 6%. Furthermore, both accurate values for the target analytes ranging from 0.005 to 50 g kg(-1) and a corresponding expanded relative uncertainty of less than 12% were obtained using the ID LC-MS/MS method. More importantly, the approach is highly sensitive, selective and accurate in screening estrogens in real infant formula samples. Thus, it could be convenient for large-scale application due to its derivatization-free feature and simplicity in sample preparation.
引用
收藏
页码:3968 / 3975
页数:8
相关论文
共 50 条
  • [1] Quantitative analysis of cholesterol in infant formula by isotope dilution liquid chromatography-tandem mass spectrometry
    Ahn, Eun Jeong
    Lee, Hwa Shim
    Kim, Byung Joo
    Lee, Gae Ho
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2015, 28 (06): : 460 - 466
  • [2] Identification and Quantification of Dityrosine in Grain Proteins by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Nguyen, D. D.
    Johnson, S. K.
    Clarke, M. W.
    [J]. FOOD ANALYTICAL METHODS, 2017, 10 (10) : 3321 - 3328
  • [3] Quantification of organic contaminants in urban stormwater by isotope dilution and liquid chromatography-tandem mass spectrometry
    Fan Hou
    Zhenyu Tian
    Katherine T. Peter
    Christopher Wu
    Alex D. Gipe
    Haoqi Zhao
    Ernesto A. Alegria
    Fengmao Liu
    Edward P. Kolodziej
    [J]. Analytical and Bioanalytical Chemistry, 2019, 411 : 7791 - 7806
  • [4] Identification and Quantification of Dityrosine in Grain Proteins by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    D. D. Nguyen
    S. K. Johnson
    M. W. Clarke
    [J]. Food Analytical Methods, 2017, 10 : 3321 - 3328
  • [5] Quantification of organic contaminants in urban stormwater by isotope dilution and liquid chromatography-tandem mass spectrometry
    Hou, Fan
    Tian, Zhenyu
    Peter, Katherine T.
    Wu, Christopher
    Gipe, Alex D.
    Zhao, Haoqi
    Alegria, Ernesto A.
    Liu, Fengmao
    Kolodziej, Edward P.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (29) : 7791 - 7806
  • [6] Quantification of melatonin in human saliva by liquid chromatography-tandem mass spectrometry using stable isotope dilution
    Eriksson, K
    Östin, A
    Levin, JO
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01): : 115 - 123
  • [7] Pantothenic acid quantification by a stable isotope dilution assay based on liquid chromatography-tandem mass spectrometry
    Rychlik, M
    [J]. ANALYST, 2003, 128 (07) : 832 - 837
  • [8] Determination of Pentachlorophenol in Milk Powder by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Qi, Yan
    Li, Jinqing
    Li, Cong
    Xu, Qingpeng
    [J]. Shipin Kexue/Food Science, 2023, 44 (16): : 324 - 330
  • [9] Determination of serum/plasma aldosterone by isotope dilution liquid chromatography-tandem mass spectrometry
    Zheng, G.
    Wang, X.
    Zhou, W.
    Xu, R.
    Li, T.
    [J]. CLINICA CHIMICA ACTA, 2024, 558
  • [10] Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry
    Aguas, Patricia C.
    Fitzhenry, Matthew J.
    Giannikopoulos, Georgina
    Varelis, Peter
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1526 - 1531