The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy

被引:17
|
作者
Gear, J. I. [1 ]
Flux, G. D.
Charles-Edwards, E.
Partridge, M.
Cook, G.
Ott, R. J.
机构
[1] Royal Marsden NHS Fdn Trust & Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[2] Royal Marsden NHS Fdn Trust & Inst Canc Res, Clin Magnet Res Grp, Sutton, Surrey, England
[3] Royal Marsden NHS Fdn Trust & Inst Canc Res, Dept Nucl Med, Sutton, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 14期
关键词
D O I
10.1088/0031-9155/51/14/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is a lack of standardized methodology to perform dose calculations for targeted radionuclide therapy and at present no method exists to objectively evaluate the various approaches employed. The aim of the work described here was to investigate the practicality and accuracy of calibrating polymer gel dosimeters such that dose measurements resulting from complex activity distributions can be verified. Twelve vials of the polymer gel dosimeter, 'MAGIC', were uniformly mixed with varying concentrations of P-32 such that absorbed doses ranged from 0 to 30 Gy after a period of 360 h before being imaged on a magnetic resonance scanner. In addition, nine vials were prepared and irradiated using an external 6 MV x-ray beam. Magnetic resonance transverse relaxation time, T-2, maps were obtained using a multi-echo spin echo sequence and converted to R-2 maps (where T-2 = 1/R-2). Absorbed doses for P-32 irradiated gel were calculated according to the medical internal radiation dose schema using EGSnrc Monte Carlo simulations. Here the energy deposited in cylinders representing the irradiated vials was scored. A relationship between dose and R-2 was determined. Effects from oxygen contamination were present in the internally irradiated vials. An increase in O-2 sensitivity over those gels irradiated externally was thought to be a result of the longer irradiation period. However, below the region of contamination dose response appeared homogenous. Due do a drop-off of dose at the periphery of the internally irradiated vials, magnetic resonance ringing artefacts were observed. The ringing did not greatly affect the accuracy of calibration, which was comparable for both methods. The largest errors in calculated dose originated from the initial activity measurements, and were approximately 10%. Measured R2 values ranged from 5-35 s(-1) with an average standard deviation of 1%. A clear relationship between R-2 and dose was observed, with up to 40% increased sensitivity for internally irradiated gels. Curve fits to the calibration data followed a single exponential function. The correlation coefficients for internally and externally irradiated gels were 0.991 and 0.985, respectively. With the ability to accurately calibrate internally dosed polymer gels, this technology shows promise as a means to evaluate dosimetry methods, particularly in cases of non-uniform uptake of a radionuclide.
引用
收藏
页码:3503 / 3516
页数:14
相关论文
共 50 条
  • [1] Polymer Gel Dosimeters for use in Targeted Radionuclide Therapy
    Gear, J. I.
    Flux, G. D.
    Partridge, M.
    Ott, R. J.
    Charles-Edwards, E.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207
  • [2] Imaging dose: Calibration of polymer gel dosimeters for use in targeted radionuclide therapy
    Gear, Jonathan I.
    Flux, Glenn D.
    Charles-Edwards, Elizabeth
    Partridge, Mike
    Cook, Gary
    Ott, Robert J.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2664 - 2668
  • [3] Novel SPECT/CT Phantom with Active and Passive Dosimeters for Targeted Radionuclide Therapy Dosimetry
    Bertinetti, A.
    Rodrigues, M.
    Garcia, T.
    Palmer, B.
    Hammer, C.
    Vija, H.
    Culberson, W.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E578 - E578
  • [4] Organs dosimetry in targeted radionuclide therapy
    Alnaaimi, Meshari
    Sulieman, Abdelmoneim
    Alkhorayef, Mohammed
    Salah, Hasan
    Alduaij, Musa
    Algaily, Mosab
    Alomair, O.
    Alashban, Y.
    Almohammad, H., I
    Bradley, David
    Kappas, C.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [5] ACCURATE DOSIMETRY FOR TARGETED RADIONUCLIDE THERAPY
    DEWHURST, SE
    RIGGS, SJ
    GREEN, AJ
    BEGENT, RHT
    BAGSHAWE, KD
    [J]. BRITISH JOURNAL OF CANCER, 1989, 59 (05) : 829 - 829
  • [6] Organs dosimetry in targeted radionuclide therapy
    Alnaaimi, Meshari
    Sulieman, Abdelmoneim
    Alkhorayef, Mohammed
    Salah, Hasan
    Alduaij, Musa
    Algaily, Mosab
    Alomair, O.
    Alashban, Y.
    Almohammad, H.I.
    Bradley, David
    Kappas, C.
    [J]. Radiation Physics and Chemistry, 2021, 188
  • [7] Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study
    Gear, J. I.
    Charles-Edwards, E.
    Partridge, M.
    Flux, G. D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22): : 7273 - 7286
  • [8] Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry
    Jirasek, A.
    Hilts, M.
    McAuley, K. B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18): : 5269 - 5281
  • [9] Multicellular dosimetry in voxel geometry for targeted radionuclide therapy
    Malaroda, A
    Flux, GD
    Buffa, FM
    Ott, RJ
    [J]. CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2003, 18 (03) : 451 - 461
  • [10] The Impact of PET and SPECT on Dosimetry for Targeted Radionuclide Therapy
    Flux, Glenn
    Bardies, Manuel
    Monsieurs, Myriam
    Savolainen, Sauli
    Strand, Sven-Erik
    Lassmann, Michael
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (01): : 47 - 59