Air quality and passenger comfort in an air-conditioned bus micro-environment

被引:9
|
作者
Zhu, Xiaoxuan [1 ]
Lei, Li [2 ]
Wang, Xingshen [3 ]
Zhang, Yinghui [2 ]
机构
[1] Shandong Yingcai Univ, Sch Automot Engn, POB 250104, Jinan, Shandong, Peoples R China
[2] Shandong Univ, Sch Energy & Power Engn, POB 250061, Jinan, Shandong, Peoples R China
[3] Beijing Jiaotong Univ, Sch Traff & Transportat, POB 100044, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-conditioned bus micro-environment; Passenger comfort level; Discrete phase model (DPM); Inhalable particles; PM10; Ventilation parameters; PARTICLE CONCENTRATIONS; ULTRAFINE PARTICLES; SCHOOL BUSES; HONG-KONG; ENVIRONMENT; EXPOSURE; CABIN; PM2.5;
D O I
10.1007/s10661-018-6593-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, passenger comfort and the air pollution status of the micro-environmental conditions in an air-conditioned bus were investigated through questionnaires, field measurements, and a numerical simulation. As a subjective analysis, passengers' perceptions of indoor environmental quality and comfort levels were determined from questionnaires. As an objective analysis, a numerical simulation was conducted using a discrete phase model to determine the diffusion and distribution of pollutants, including particulate matter with a diameter < 10 mu m(PM10), which were verified by experimental results. The results revealed poor air quality and dissatisfactory thermal comfort conditions in Jinan's air-conditioned bus system. To solve these problems, three scenarios (schemes A, B, C) were designed to alter the ventilation parameters. According to the results of an improved simulation of these scenarios, reducing or adding air outputs would shorten the time taken to reach steady-state conditions and weaken the airflow or lower the temperature in the cabin. The airflow pathway was closely related to the layout of the air conditioning. Scheme B lowered the temperature by 0.4 K and reduced the airflow by 0.01 m/s, while scheme C reduced the volume concentration of PM10 to 150 mu g/m(3). Changing the air supply angle could further improve the airflow and reduce the concentration of PM10. With regard to the perception of airflow and thermal comfort, the scheme with an airflow provided by a 60 degrees nozzle was considered better, and the concentration of PM10 was reduced to 130 mu g/m(3).
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Air quality and passenger comfort in an air-conditioned bus micro-environment
    Xiaoxuan Zhu
    Li Lei
    Xingshen Wang
    Yinghui Zhang
    [J]. Environmental Monitoring and Assessment, 2018, 190
  • [2] Correction to: Air quality and passenger comfort in an air-conditioned bus micro-environment
    Xiaoxuan Zhu
    Li Lei
    Yinghui Zhang
    Xingshen Wang
    [J]. Environmental Monitoring and Assessment, 2018, 190
  • [3] Air quality and passenger comfort in an air-conditioned bus micro-environment (vol 190, 276, 2018)
    Zhu, Xiaoxuan
    Lei, Li
    Zhang, Yinghui
    Wang, Xingshen
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (09)
  • [4] Passenger comfort and ozone pollution exposure in an air-conditioned bus microenvironment
    Xiaoxuan Zhu
    Li Lei
    Jitian Han
    Peng Wang
    Fushun Liang
    Xingshen Wang
    [J]. Environmental Monitoring and Assessment, 2020, 192
  • [5] Passenger comfort and ozone pollution exposure in an air-conditioned bus microenvironment
    Zhu, Xiaoxuan
    Lei, Li
    Han, Jitian
    Wang, Peng
    Liang, Fushun
    Wang, Xingshen
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (08)
  • [6] Microbial Air Quality in Air-conditioned Passenger Cars
    Golofit-Szymczak, Malgorzata
    Stobnicka-Kupiec, Agata
    [J]. ROCZNIK OCHRONA SRODOWISKA, 2018, 20 : 1564 - 1582
  • [7] Air Quality Assessment for the Microenvironment in Air-conditioned Passenger Trains
    Cai Wei
    Wang Danjun
    Yu Xubo
    [J]. EBM 2010: INTERNATIONAL CONFERENCE ON ENGINEERING AND BUSINESS MANAGEMENT, VOLS 1-8, 2010, : 3601 - 3604
  • [8] Indoor air pollution in Air-Conditioned bus and non-Air-Conditioned bus
    Husna, I. E.
    Unzilatirrizqi, Y. E. R. D.
    Sarifuddin
    Wijinurhayati, A. A.
    [J]. 2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623
  • [9] Dynamic evaluation of thermal comfort environment of air-conditioned buildings
    Wang Hanqing
    Huang Chunhua
    Liu Zhiqiang
    Tang Guangfa
    Liu Yingyun
    Wang Zhiyong
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (11) : 1522 - 1529
  • [10] Comfort Zone of Air Speeds and Temperatures for Air-conditioned Environment in the Subtropical Hong Kong
    Fong, K. F.
    Chow, T. T.
    Li, C.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2010, 19 (03) : 375 - 381