Optimum insulation thickness for external walls on different orientations considering the speed and direction of the wind

被引:52
|
作者
Axaopoulos, Ioannis [1 ]
Axaopoulos, Petros [2 ]
Gelegenis, John [2 ]
机构
[1] Natl Tech Univ Athens, Sch Mech Engn, GR-10682 Athens, Greece
[2] Technol Educ Inst Athens, Dept Energy Technol, Ag Spyridonos 12210, Aegaleo, Greece
关键词
Optimum insulation thickness; Heating load; Cooling load; TRNSYS; Wind direction; Life cycle savings; HEAT-TRANSFER COEFFICIENT; BUILDING WALLS; ENERGY SAVINGS; CLIMATE; PERFORMANCE; CONSUMPTION; SURFACES; REGIONS; IMPACT; TURKEY;
D O I
10.1016/j.apenergy.2013.12.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal insulation is generally installed in the envelope of residential buildings to improve their thermal performance. However, the selection of the optimum insulation thickness requires a detailed thermal energy and economic analysis. This paper determines the optimum insulation thickness for external walls of different composition and orientation, considering both the heating and cooling period and taking into account the wind speed and direction. Three types of composite, thermally insulated walls have been selected. Annual heating and cooling transmission loads are being calculated based on transient heat flow through the external walls and by using hourly climatic data of the city of Athens, Greece. The available wind speed and direction data have been statistically analyzed for the assessment of the prevalent wind directions in the area. An economic analysis, based on the life cycle savings method has been performed for each configuration, various thicknesses of insulation material and different orientations. The optimum insulation thickness for any type of wall and orientation was found to be between 7.1 cm and 10.1 cm. Furthermore, a sensitivity analysis indicates whether changes of the economic parameters affect the optimum insulation thickness. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 50 条
  • [1] Optimal economic thickness of various insulation materials for different orientations of external walls considering the wind characteristics
    Axaopoulos, Ioannis
    Axaopoulos, Petros
    Panayiotou, Gregoris
    Kalogirou, Soteris
    Gelegenis, John
    [J]. ENERGY, 2015, 90 : 939 - 952
  • [2] ANALYSIS OF OPTIMUM INSULATION THICKNESS FOR EXTERNAL WALLS AT DIFFERENT ORIENTATIONS BASED ON REAL-TIME MEASUREMENTS
    Onan, Cenk
    Erdem, Serkan
    Ozkan, Derya Burcu
    Baykal, Cem
    [J]. THERMAL SCIENCE, 2020, 24 (03): : 2035 - 2046
  • [3] Optimum insulation thickness for external building walls for different climate zone in India
    Shahid, Mohd
    Karimi, Munawar Nawab
    Mishra, Atul Kumar
    [J]. JOURNAL OF THERMAL ENGINEERING, 2024, 10 (05): : 1198 - 1211
  • [4] Application of three different methods for determination of optimum insulation thickness in external walls
    Ucar, Aynur
    Inalli, Mustafa
    Balo, Figen
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2011, 30 (04) : 709 - 719
  • [5] Optimum insulation thickness of external walls for energy saving
    Çomakli, K
    Yüksel, B
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (04) : 473 - 479
  • [6] Financially Optimum Insulation Thickness of External Building Walls
    Axaopoulos, Petros J.
    Fylladitakis, Emmanouil D.
    Shabdurakhmanovich, Shaislamov Alisher
    Ogli, Abdullaev Nodirbek Azatvay
    [J]. TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY: TMREES19GR, 2019, 2190
  • [7] Determination of optimum insulation thickness of external walls with two different methods in cooling applications
    Kayfeci, Muhammet
    Kecebas, Ali
    Gedik, Engin
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 217 - 224
  • [8] The environmental impact of optimum insulation thickness for external walls of buildings
    Dombayci, Oe. Altan
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (11) : 3855 - 3859
  • [9] Parametric Investigation of Optimum Thermal Insulation Thickness for External Walls
    Kaynakli, Omer
    [J]. ENERGIES, 2011, 4 (06): : 913 - 927
  • [10] Analysis on optimum insulation thickness of external thermal insulation walls in Nanjing zone
    Xu, Chengcheng
    Li, Shuhong
    [J]. Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (03): : 558 - 564