Bacterial contamination of neonatal intensive care units: How safe are the neonates?

被引:15
|
作者
Bhatta, Dharm Raj [1 ]
Hosuru Subramanya, Supram [1 ]
Hamal, Deependra [1 ]
Shrestha, Rajani [1 ]
Gauchan, Eva [2 ]
Basnet, Sahisnuta [2 ]
Nayak, Niranjan [1 ]
Gokhale, Shishir [1 ]
机构
[1] Manipal Coll Med Sci, Dept Microbiol, Pokhara, Nepal
[2] Manipal Coll Med Sci, Dept Pediat & Neonatol, Pokhara, Nepal
关键词
NICU; Nosocomial infections; Bacterial contamination; Disinfection; Antibiotic resistance; NOSOCOMIAL INFECTIONS; RISK-FACTORS; RESISTANCE; PATHOGENS; SURFACES;
D O I
10.1186/s13756-021-00901-2
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background Intensive care units (ICU) are essential healthcare facility for life threatening conditions. Bacterial contamination of objects/instruments in ICU is an important source of nosocomial infections. This study is aimed to determine the level of bacterial contamination of instruments/objects which are commonly touched by healthcare workers and frequently come in contact with the neonates. Methods This hospital based prospective study was conducted in neonatal intensive care unit (NICU) of Manipal Teaching Hospital, Pokhara, Nepal. A total of 146 samples collected from surfaces of incubators, radiant warmers, suction tips, ventilators, stethoscopes, door handles, weighing machines, mothers' beds, phototherapy beds, laryngoscope, telephone sets, blood pressure machine, etc. formed the material of the study. Isolation, identification and antibiotic susceptibility of the bacterial isolates was performed by standard techniques. Blood culture isolates from NICU patients during the study period were compared with the environmental isolates. Results Out of 146 samples, bacterial growth was observed in 109. A total of 119 bacterial isolates were retrieved from 109 samples. Three common potential pathogens isolated were Escherichia coli (n = 27), Klebsiella species (n = 21) and Staphylococcus aureus (n = 18). Majority of E. coli and Klebsiella isolates were from incubators, suction tips and mothers' beds. Majority of S. aureus isolates were cultured from radiant warmers. Among S. aureus isolates, 33.3% (6/18) were methicillin resistant. Majority of the bacterial isolates were susceptible to gentamicin and amikacin. Common potential pathogens isolated from blood culture of NICU patients were S. aureus and Klebsiella species. Conclusion High degree of bacterial contamination of objects/instruments in NICU was recorded. Isolation of potential pathogens like E. coli, Klebsiella species and S. aureus is a major threat of nosocomial infections. Blood culture data of NICU reflects possibility of nosocomial infections from contaminated sites. Gentamicin and amikacin may be used for empirical therapy in suspected cases of nosocomial infections in NICU.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Bacterial contamination of neonatal intensive care units: How safe are the neonates?
    Dharm Raj Bhatta
    Supram Hosuru Subramanya
    Deependra Hamal
    Rajani Shrestha
    Eva Gauchan
    Sahisnuta Basnet
    Niranjan Nayak
    Shishir Gokhale
    [J]. Antimicrobial Resistance & Infection Control, 10
  • [2] Bacterial Contamination of Neonatal Intensive Care Units (NICU)
    Yousefimashouf, R.
    Farajianzadeh, A.
    Heidari, M.
    [J]. PEDIATRIC PULMONOLOGY, 2021, 56 : S186 - S186
  • [3] Bacterial colonization patterns in neonates transferred from neonatal intensive care units
    Navarro, L. R.
    Pekelharing-Berghuis, M.
    de Waal, W. J.
    Thijsen, S. F.
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2011, 214 (02) : 167 - 171
  • [4] Antibiotic stewardship in neonates and in neonatal intensive care units
    Mukhopadhyay, Sagori
    [J]. SEMINARS IN PERINATOLOGY, 2020, 44 (08)
  • [5] Unintentional exposure of neonates to conventional radiography in the Neonatal Intensive Care Units
    Bader, D.
    Datz, H.
    Bartal, G.
    Juster, A. A.
    Marks, K.
    Smolkin, T.
    Zangen, S.
    Kugelman, A.
    Hoffmann, C.
    Shani, G.
    Ben-Shlomo, A.
    Margaliot, M.
    Sadetzki, S.
    [J]. JOURNAL OF PERINATOLOGY, 2007, 27 (09) : 579 - 585
  • [6] Unintentional exposure of neonates to conventional radiography in the Neonatal Intensive Care Units
    D Bader
    H Datz
    G Bartal
    A A Juster
    K Marks
    T Smolkin
    S Zangen
    A Kugelman
    C Hoffmann
    G Shani
    A Ben–shlomo
    M Margaliot
    S Sadetzki
    [J]. Journal of Perinatology, 2007, 27 : 579 - 585
  • [7] Bacterial Diversity in Two Neonatal Intensive Care Units (NICUs)
    Hewitt, Krissi M.
    Mannino, Frank L.
    Gonzalez, Antonio
    Chase, John H.
    Caporaso, J. Gregory
    Knight, Rob
    Kelley, Scott T.
    [J]. PLOS ONE, 2013, 8 (01):
  • [8] Study on Bacterial Contamination of Neonatal Intensive Care Units (NICU) in a Pediatric Hospital in Hamadan, West of Iran.
    Yousefimashouf, M. R.
    [J]. PEDIATRIC PULMONOLOGY, 2018, 53 : S166 - S167
  • [9] Risk factors for hearing loss in neonates admitted to neonatal intensive care units
    Pan, L.
    Fang, X.
    Chen, H.
    Zhai, F.
    Chen, J.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2022, 136 (12): : 1196 - 1202
  • [10] Microbiological contamination of mobile phones of clinicians in intensive care units and neonatal care units in public hospitals in Kuwait
    Heyba, Mohammed
    Ismaiel, Mohammad
    Alotaibi, Abdulrahman
    Mahmoud, Mohamed
    Baqer, Hussain
    Safar, Ali
    Al-Sweih, Noura
    Al-Taiar, Abdullah
    [J]. BMC INFECTIOUS DISEASES, 2015, 15