On the feasibility of comprehensive high-resolution 3D remote dosimetry

被引:17
|
作者
Juang, Titania [1 ,2 ]
Grant, Ryan [3 ,4 ]
Adamovics, John [5 ]
Ibbott, Geoffrey [4 ]
Oldham, Mark [2 ]
机构
[1] Duke Univ, Med Ctr, Med Phys Grad Program, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Dept Radiat Oncol Phys, Durham, NC 27710 USA
[3] Univ Texas Hlth Sci Ctr Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[5] Rider Univ, Dept Chem & Biol, Lawrenceville, NJ 08648 USA
基金
美国国家卫生研究院;
关键词
Remote dosimetry; 3D dosimetry; optical-CT; PRESAGE (R); quality assurance; PRESAGE/OPTICAL-CT; IMRT; IMPLEMENTATION; PHANTOM; DESIGN; SYSTEM;
D O I
10.1118/1.4884018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigates the feasibility of remote high-resolution 3D dosimetry with the PRESAGE (R))/Optical-CT system. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote institution for irradiation, then shipped back to the base institution for subsequent readout and analysis. Methods: Two nominally identical optical-CT scanners for 3D dosimetry were constructed and placed at the base (Duke University) and remote (Radiological Physics Center) institutions. Two formulations of PRESAGE (R) (SS1, SS2) radiochromic dosimeters were investigated. Higher sensitivity was expected in SS1, which had higher initiator content (0.25% bromotrichloromethane), while greater temporal stability was expected in SS2. Four unirradiated PRESAGE (R) dosimeters (two per formulation, cylindrical dimensions 11 cm diameter, 8.5-9.5 cm length) were imaged at the base institution, then shipped to the remote institution for planning and irradiation. Each dosimeter was irradiated with the same simple treatment plan: an isocentric 3-field "cross" arrangement of 4 x 4 cm open 6 MV beams configured as parallel opposed laterals with an anterior beam. This simple plan was amenable to accurate and repeatable setup, as well as accurate dose modeling by a commissioned treatment planning system (Pinnacle). After irradiation and subsequent (within 1 h) optical-CT readout at the remote institution, the dosimeters were shipped back to the base institution for remote dosimetry readout 3 days postirradiation. Measured on-site and remote relative 3D dose distributions were registered to the Pinnacle dose calculation, which served as the reference distribution for 3D gamma calculations with passing criteria of 5%/2 mm, 3%/3 mm, and 3%/2 mm with a 10% dose threshold Gamma passing rates, dose profiles, and color-maps were all used to assess and compare the performance of both PRESAGE (R) formulations for remote dosimetry. Results: The best agreements between the Pinnacle plan and dosimeter readout were observed in PRESAGE (R) formulation SS2. Under 3%/3 mm 3D gamma passing criteria, passing rates were 91.5% +/- 3.6% (SS1) and 97.4% +/- 2.2% (SS2) for immediate on-site dosimetry, 96.7% +/- 2.4% (SS1) and 97.6% +/- 0.6% (SS2) for remote dosimetry. These passing rates are well within TG119 recommendations (88%-90% passing). Under the more stringent criteria of 3%/2 mm, there is a pronounced difference [8.0 percentage points (pp)] between SS1 formulation passing rates for immediate and remote dosimetry while the SS2 formulation maintains both higher passing rates and consistency between immediate and remote results (differences <= 1.2 pp) at all metrics. Both PRESAGE (R) formulations under study maintained high linearity of dose response (R-2 > 0.996) for 1-8 Gy over 14 days with response slope consistency within 4.9% (SS1) and 6.6% (SS2), and a relative dose distribution that remained stable over time was demonstrated in the SS2 dosimeters. Conclusions: Remote 3D dosimetry was shown to be feasible with a PRESAGE (R) dosimeter formulation (SS2) that exhibited relative temporal stability and high accuracy when read off-site 3 days postirradiation. Characterization of the SS2 dose response demonstrated linearity (R-2 > 0.998) over 14 days and suggests accurate readout over longer periods of time would be possible. This result provides a foundation for future investigations using remote dosimetry to study the accuracy of advanced radiation treatments. Further work is planned to characterize dosimeter reproducibility and dose response over longer periods of time. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] FEASIBILITY OF HIGH-RESOLUTION, 3D, EM PARTICLE SIMULATIONS
    BUNEMAN, O
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 1094 - 1094
  • [2] Calibration Accuracy in Mailed High-Resolution 3D Dosimetry Service for SRS/SBRT QA
    Maryanski, M.
    Keane, J.
    Zimberg, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 325 - 325
  • [3] High-resolution 3D printing in seconds
    Darkes-Burkey, Cameron
    Shepherd, Robert F.
    [J]. NATURE, 2020, 588 (7839) : 594 - 595
  • [4] 3D High-Resolution Geophysical Surveys
    Sack, Peter
    Haugland, Tor
    [J]. SEA TECHNOLOGY, 2012, 53 (10) : 23 - +
  • [5] 3D mapping with high-resolution images
    Toutin, T
    Chénier, R
    Carbonneau, Y
    Alcaïde, N
    [J]. GEOINFORMATION FOR EUROPEAN-WIDE INTEGRATION, 2003, : 121 - 125
  • [6] High-resolution 3D survey of artworks
    Fontana, R
    Gambino, MC
    Mazzotta, C
    Greco, M
    Pampaloni, E
    Pezzati, L
    [J]. OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 719 - 726
  • [7] High-resolution 3D imaging of tissue
    Burgess, Sean A.
    Yuan, Baohong
    Radosevich, Andrew J.
    Bouchard, Mathew B.
    Hillman, Elizabeth M. C.
    [J]. 2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 5 - 6
  • [8] High-resolution 3D genome characterization
    Burgess D.
    [J]. Nature Reviews Genetics, 2021, 22 (8) : 481 - 481
  • [9] High-Resolution 3D Printing for Electronics
    Park, Young-Geun
    Yun, Insik
    Chung, Won Gi
    Park, Wonjung
    Lee, Dong Ha
    Park, Jang-Ung
    [J]. ADVANCED SCIENCE, 2022, 9 (08)
  • [10] High-resolution 3D printing in seconds
    Cameron Darkes-Burkey
    Robert F. Shepherd
    [J]. Nature, 2020, 588 : 594 - 595