摘要
We describe the results of our effort to optimize three neutron detector systems for active interrogation of highly enriched uranium: 1) a large-area detector for maximum total efficiency, 2) modular detectors for maximum flexibility in configuring a detector system for an application, and 3) a portable detector. All three systems contained He-3 tubes, polyethylene to moderate the neutrons, and cadmium to filter out room-return thermal neutrons. The back and sides of the detectors were shielded with additional polyethylene or borated polyethylene. The electronics gated off the data acquisition during the interrogating pulse, either bremsstrahlung photons from an electron linac or neutrons from a DT generator. The sensitivity of each detector system depends on the distance between the detector and nuclear material as well as on the intervening material. We present representative data for several configurations showing the performance of each system.
引用
收藏
页码:1440 / 1443
页数:4
相关论文
共 50 条
  • [1] Neutron, detectors for active interrogation of highly enriched uranium
    Moss, CE
    Goulding, CA
    Hollas, CL
    Myers, WL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1677 - 1681
  • [2] Photon and neutron active interrogation of highly enriched uranium
    Myers, WL
    Goulding, CA
    Hollas, CL
    Moss, CE
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 1688 - 1692
  • [3] Parametric Evaluation of Active Neutron Interrogation for the Detection of Shielded Highly-Enriched Uranium in the Field
    Chichester, David L.
    Thompson, Scott J.
    Seabury, Edward H.
    Clement, Ryan R. C.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 964 - 971
  • [4] Linear accelerator-based active interrogation for detection of highly enriched uranium
    Moss, CE
    Goulding, CA
    Hollas, CL
    Myers, WL
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2003, 680 : 900 - 904
  • [5] Neutron interrogation of high-enriched uranium by a 4 MeV linac
    Lakosi, Laszlo
    Nguyen, Cong Tam
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (14): : 3295 - 3301
  • [6] Active detection of small quantities of shielded highly-enriched uranium using low-dose 60-kev neutron interrogation
    Kerr, Phil
    Rowland, Mark
    Dietrich, Dan
    Stoeffl, Wolfgang
    Wheeler, Boyd
    Nakae, Les
    Howard, Doug
    Hagmann, Chris
    Newby, Jason
    Porter, Robert
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 347 - 350
  • [7] Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification
    Hamel, Michael C.
    Polack, J. Kyle
    Ruch, Marc L.
    Marcath, Matthew J.
    Clarke, Shaun D.
    Pozzi, Sara A.
    SCIENTIFIC REPORTS, 2017, 7
  • [8] Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification
    Michael C. Hamel
    J. Kyle Polack
    Marc L. Ruch
    Matthew J. Marcath
    Shaun D. Clarke
    Sara A. Pozzi
    Scientific Reports, 7
  • [9] Detection and Characterization of Shielded Highly Enriched Uranium Under Active Interrogation Through Time Correlated Fission Events
    Monterial, Mateusz
    Marleau, Peter
    Pozzi, Sara A.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [10] Pion-muon concentrating system for detectors of highly enriched uranium
    Kurennoy, S
    Neri, F
    Barlow, D
    Blind, B
    Jason, A
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 2436 - 2438