Ultrasonic wireless health monitoring

被引:0
|
作者
Petit, Lionel [1 ]
Lefeuvre, Elie [1 ]
Guyomar, Daniel [1 ]
Richard, Claude [1 ]
Guy, Philippe [2 ]
Yuse, Kaori [2 ]
Monnier, Thomas [1 ]
机构
[1] Inst Natl Sci Appl, LGEF, 8 Rue Phys, F-69621 Villeurbanne, France
[2] LGEF, GEMPPM, F-69621 Villeurbanne, France
关键词
piezoelectric; health monitoring; autonomous; wireless; energy harvesting;
D O I
10.1117/12.661130
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The integration of autonomous wireless elements in health monitoring network increases the reliability by suppressing power supplies and data transmission wiring. Micro-power piezoelectric generators are an attractive alternative to primary batteries which are limited by a finite amount of energy, a limited capacity retention and a short shelf life (few years). Our goal is to implement such an energy harvesting system for powering a single AWT (Autonomous Wireless Transmitter) using our SSH (Synchronized Switch Harvesting) method. Based on a non linear process of the piezoelement voltage, this SSH method optimizes the energy extraction from the mechanical vibrations. This AWT has two main functions : The generation of an identifier code by RF transmission to the central receiver and the Lamb wave generation for the health monitoring of the host structure. A damage index is derived from the variation between the transmitted wave spectrum and a reference spectrum. The same piezoelements are used for the energy harvesting function and the Lamb wave generation, thus reducing mass and cost. A micro-controller drives the energy balance and synchronizes the functions. Such an autonomous transmitter has been evaluated on a 300x50x2 mm(3) Composite cantilever beam. Four 33x11x0.3 mm(3) piezoelements are used for the energy harvesting and for the wave lamb generation. A piezoelectric sensor is placed at the free end of the beam to track the transmitted Lamb wave. In this configuration, the needed energy for the RF emission is 0.1 mJ for a 1 byte-information and the Lamb wave emission requires less than 0.1 mJ. The AWT can harvested an energy quantity of approximately 20 mJ (for a 1.5 Mpa lateral stress) with a 470 mu F storage capacitor. This corresponds to a power density near to 6mW/cm(3). The experimental AWT energy abilities are presented and the damage detection process is discussed. Finally, some envisaged solutions are introduced for the implementation of the required data processing into an autonomous wireless receiver, in terms of reduction of the energy and memory costs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Shimmer: a Wireless Harvesting Embedded System for Active Ultrasonic Structural Health Monitoring
    Dondi, Denis
    Di Pompeo, Alex
    Tenti, Cristiana
    Rosing, Tajana Simunic
    2010 IEEE SENSORS, 2010, : 2325 - 2328
  • [2] Wireless health monitoring
    Ohtsuki, Tomoaki
    Journal of the Institute of Electronics, Information and Communication Engineers, 2014, 97 (08): : 702 - 706
  • [3] Development of a laser-powered wireless ultrasonic device for aircraft structural health monitoring
    Choi, Mijin
    Shrestha, Manish Man
    Lee, Jung-Ryul
    Park, Chan-Yik
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2018, 17 (02): : 145 - 155
  • [4] A wireless sensor system for structural health monitoring with guided ultrasonic waves and piezoelectric transducers
    Duerager, Christian
    Heinzelmann, Andreas
    Riederer, Daniela
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2013, 9 (11) : 1177 - 1186
  • [5] A wireless ultrasonic guided wave structural health monitoring system for aircraft wing inspection
    Zhao, X.
    Qian, T.
    Popovic, Z.
    Zane, R.
    Mei, G.
    Walsh, C.
    Paing, T.
    Kwan, C.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 26A AND 26B, 2007, 894 : 1548 - 1555
  • [6] Development of Laser-powered Wireless Ultrasonic Device for Aircraft Structural Health Monitoring
    Choi, Mijin
    Lee, Jung-Ryul
    Park, Chan-Yik
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 2544 - 2551
  • [7] Wireless Ultrasonic Thickness Monitoring at Elevated Temperatures
    Cegla, F.
    Allin, J.
    MATERIALS EVALUATION, 2011, 69 (05) : A26 - A31
  • [8] System for wireless health monitoring
    Kumar, A
    Rahman, F
    PROCEEDINGS OF THE ISA/IEEE SENSORS FOR INDUSTRY CONFERENCE, 2004, : 207 - 210
  • [9] Wireless Health Monitoring System
    Wcislik, M.
    Pozoga, M.
    Smerdzynski, P.
    IFAC PAPERSONLINE, 2015, 48 (04): : 312 - 317
  • [10] Wearable Wireless Health Monitoring
    Soh, Ping Jack
    Vandenbosch, Guy A. E.
    Mercuri, Marco
    Schreurs, Dominique M. M. -P
    IEEE MICROWAVE MAGAZINE, 2015, 16 (04) : 55 - 70