Impact of resolution and noise characteristics of digital radiographic detectors on the detectability of lung nodules

被引:14
|
作者
Saunders, RS [1 ]
Samei, E
Hoeschen, C
机构
[1] Duke Univ, Dept Phys, Durham, NC 27710 USA
[2] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
[4] Otto Von Guericke Univ, Dept Diagnost Radiol, Magdeburg, Germany
关键词
image quality; digital radiography; flat panel detector; computer simulation; receiver operating characteristic study; ROC;
D O I
10.1118/1.1753112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the unanswered questions in digital radiography is the connection between physical image quality metrics and clinical detection performance. In this paper, we examine the impact of two physical metrics, resolution and noise, on the detectability of nodules in a pulmonary background for specific digital radiographic detectors. A detection experiment was performed on a simulated image set using anatomical backgrounds from a high-quality lung radiograph and three different simulated nodule sizes (2-3.5 mm). The resolution and noise of the resulting images were modified using existing routines to simulate a selenium-based and a cesium iodide-based flat-panel detector at comparable exposures. A location-known-exactly (LKE) observer performance experiment was performed in which four experienced chest radiologists and three physicists specializing in chest radiology scored the images. The data from the observer experiment were analyzed by receiver operating characteristic (ROC) methodology. The detectability, as measured by the parameter A(z), was higher for the selenium detector than the cesium iodide detector for all nodule sizes by an average of 8.5%. For one nodule size (2.75 mm), the difference between detectors was statistically significant (p < 0.01). The findings indicate that for the particular task studied, the superior resolution performance of the selenium-based detector provided better detectability of subtle lung nodules even though the images had greater noise than images obtained with the cesium iodide detector. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:1603 / 1613
页数:11
相关论文
共 18 条
  • [1] Impact of resolution and noise characteristics of digital radiographic detectors on the detectability of lung nodules
    Saunders, RS
    Samei, E
    Hoeschen, C
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 16 - 25
  • [2] SIGNAL-TO-NOISE RATIOS OF DIGITAL RADIOGRAPHIC IMAGING-SYSTEMS AND THEIR RELATIONSHIP TO DETECTABILITY
    GIGER, ML
    DOI, K
    LOO, L
    ISHIDA, M
    MEDICAL PHYSICS, 1983, 10 (04) : 550 - 550
  • [3] Noise propagation in resolution modeled PET imaging and its impact on detectability
    Rahmim, Arman
    Tang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 6945 - 6968
  • [4] Impact of image quality, radiologists, lung segments, and Gunnar eyewear on detectability of lung nodules in chest CT
    Christe, Andreas
    Ebner, Lukas
    Steiger, Philipp
    Parikh, Sachin R.
    Shah, Akash D.
    Roychoudhury, Kingshuk
    Vock, Peter
    Roos, Justus E.
    ACTA RADIOLOGICA, 2013, 54 (06) : 646 - 651
  • [5] Local complexity metrics to quantify the effect of anatomical noise on detectability of lung nodules in chest CT imaging
    Smith, Taylor Brunton
    Rubin, Geoffrey D.
    Solomon, Justin
    Harrawood, Brian
    Choudhury, Kingshuk Roy
    Samei, Ehsan
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (04)
  • [6] Impact of Noise on Digital Video Traffic Characteristics
    Chen, Xiaohui
    Wang, Weidong
    Wei, Guo
    THIRD INTERNATIONAL CONFERENCE ON MULTIMEDIA AND UBIQUITOUS ENGINEERING (MUE 2009), 2009, : 120 - 124
  • [7] Development of local complexity metrics to quantify the effect of anatomical noise on detectability of lung nodules in chest CT imaging
    Solomon, Justin
    Rubin, Geoffrey
    Smith, Taylor
    Harrawood, Brian
    Choudhury, Kingshuk Roy
    Samei, Ehsan
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [8] Detectability of malignant lung nodules on FDG PET-CT: Impact of attenuation correction on visual interpretation
    Khandani, A. H.
    Rich, A. W.
    Parker, L. A.
    Ivanovic, M.
    McCartney, W. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S173 - S173
  • [9] Evaluation of resolution characteristics of digital intraoral radiographic images using a task transfer function
    Taku Kuramoto
    Shinya Takarabe
    Hiroki Tsuru
    Yusuke Shibayama
    Toyoyuki Kato
    Kazunori Yoshiura
    Oral Radiology, 2022, 38 : 638 - 644
  • [10] Evaluation of resolution characteristics of digital intraoral radiographic images using a task transfer function
    Kuramoto, Taku
    Takarabe, Shinya
    Tsuru, Hiroki
    Shibayama, Yusuke
    Kato, Toyoyuki
    Yoshiura, Kazunori
    ORAL RADIOLOGY, 2022, 38 (04) : 638 - 644