Anatomical conditions of the posterior pelvic ring regarding bisegmental transverse sacroiliac screw fixation: a 3D morphometric study of 125 pelvic CT datasets

被引:23
|
作者
Radetzki, Florian [1 ]
Wohlrab, D. [1 ]
Goehre, F. [2 ]
Noser, H. [3 ]
Delank, K. S. [1 ]
Mendel, T. [4 ,5 ]
机构
[1] Univ Halle Wittenberg, Dept Orthoped Surg, D-06112 Halle, Saale, Germany
[2] BG Kliniken Bergmannstrost, Dept Neurosurg, D-06112 Halle, Saale, Germany
[3] AO Fdn, AO Res Inst, CH-7270 Davos, Switzerland
[4] BG Kliniken Bergmannstrost, Dept Trauma Surg, D-06112 Halle, Saale, Germany
[5] Univ Jena, Dept Trauma Surg, D-07747 Jena, Germany
关键词
Sacroiliac screw; Virtual bone corridor; Sacral dysplasia; Third sacral segment; ILIOSACRAL SCREWS; SAFE PLACEMENT; BONE CORRIDORS; FRACTURES; SACRUM; ARCHITECTURE; INSERTION;
D O I
10.1007/s00402-014-2022-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Sacroiliac (SI) screws are used for osteosynthesis in unstable posterior pelvic ring injuries. In the cases of "sacral dysplasia", in which the elevated upper sacrum does not allow a secure SI screw insertion into the S1 level, the S2 segment must be used to achieve stable fixation. The bone quality of the S2 segment is thinner compared to that of the S1 vertebra and may cause biomechanical weakness. An additional SI screw insertion into the S3 level may improve stability. With respect to the anatomical conditions of the posterior pelvic ring, there have been no anatomical investigations to date regarding SI screw placement into the third sacral segment. CT raw datasets from 125 patients (o59 years, o172 cm, o76 kg) were post-processed using Amira 5.2 software to generate 3D pelvic models. A program code implemented in C++ computed a transverse bone corridor for the first, second and third sacral segments for a typical SI screw diameter of 7.3 mm. Volume, sagittal cross-section, iliac entrance area and length of the determined screw corridors were measured. A confidence interval of 95 % was assumed (p < 0.05). The fully automatic computation revealed a possible transverse insertion for one 7.3-mm screw in the third sacral segment in 30 cases (24 %). The rate (60 %) of feasible S3 screw placements in the cases of sacral dysplasia (n = 25) is significantly higher compared to that (15 %) of "normal" sacra (n = 100). With regard to the existence of transverse iliosacroiliac corridors as a function of sacral position in between the adjacent iliac bone bilaterally, a new classification of three different shape conditions can be made: caudad, intermediate minor, intermediate major, and cephalad sacrum. Gender, age, body height and body weight had no statistically significant influence on either possible screw insertion or on the calculated data of the corridors (p > 0.05). SI screw insertion into the third sacral level deserves discussion in the cases of sacral dysplasia. Biomechanical and practical utility must be verified.
引用
收藏
页码:1115 / 1120
页数:6
相关论文
共 17 条
  • [1] Anatomical conditions of the posterior pelvic ring regarding bisegmental transverse sacroiliac screw fixation: a 3D morphometric study of 125 pelvic CT datasets
    Florian Radetzki
    D. Wohlrab
    F. Goehre
    H. Noser
    K. S. Delank
    T. Mendel
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1115 - 1120
  • [2] Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation
    Augustinus Ludwig Jacob
    Peter Messmer
    Klaus-Wilhelm Stock
    Norbert Suhm
    Bernard Baumann
    Pietro Regazzoni
    Wolfgang Steinbrich
    CardioVascular and Interventional Radiology, 1997, 20 : 285 - 294
  • [3] Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation
    Jacob, AL
    Messmer, P
    Stock, KW
    Suhm, N
    Baumann, B
    Regazzoni, P
    Steinbrich, W
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 20 (04) : 285 - 294
  • [4] Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study
    Lodde, Moritz F.
    Katthagen, J. Christoph
    Schopper, Clemens O.
    Zderic, Ivan
    Richards, R. Geoff
    Gueorguiev, Boyko
    Raschke, Michael J.
    Hartensuer, Rene
    MEDICINA-LITHUANIA, 2021, 57 (12):
  • [5] Use of 3D Navigation Versus Traditional Fluoroscopy for Posterior Pelvic Ring Fixation
    Passias, Braden J.
    Grenier, Greg
    Buchan, John
    Buchan, Daniel R.
    Scheschuk, Joseph
    Taylor, Benjamin C.
    ORTHOPEDICS, 2021, 44 (04) : 229 - 234
  • [6] Anatomical evaluation of the transpubic screw corridor based on a 3D statistical model of the pelvic ring
    Charlotte Arand
    Daniel Wagner
    Robert Geoff Richards
    Hansrudi Noser
    Lukas Kamer
    Dominic Gehweiler
    Johannes Hopf
    Pol M. Rommens
    Scientific Reports, 11
  • [7] Anatomical evaluation of the transpubic screw corridor based on a 3D statistical model of the pelvic ring
    Arand, Charlotte
    Wagner, Daniel
    Richards, Robert Geoff
    Noser, Hansrudi
    Kamer, Lukas
    Gehweiler, Dominic
    Hopf, Johannes
    Rommens, Pol M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] 3D-Navigated percutaneous screw fixation of pelvic ring injuries - a pilot study
    Michela, Florio
    Capasso, Luigi
    Olivi, Alessandro
    Vitiello, Carla
    Leone, Antonio
    Liuzza, Francesco
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 : S28 - S33
  • [9] Positioning of sacroiliac screws using an intraoperative 3D CT (O-Arm©) guided navigation in posterior pelvic ring fractures
    Potocnik, Primoz
    Arigoni, Michele
    Candrian, Christian
    SWISS MEDICAL WEEKLY, 2013, 143 : 29S - 29S
  • [10] Intraoperative CT-assisted sacroiliac screws fixation for the treatment of posterior pelvic ring injury: a comparative study with conventional intraoperative imaging
    Yang, Zhanyu
    Sheng, Bin
    Liu, Delong
    Chen, Xintong
    Guan, Rui
    Wang, Yiwei
    Liu, Chao
    Xiao, Rui
    SCIENTIFIC REPORTS, 2022, 12 (01)