Water-perfused esophageal high-resolution manometry: normal values and validation

被引:44
|
作者
Kessing, Boudewijn F. [1 ]
Weijenborg, Pim W. [1 ]
Smout, Andre J. P. M. [1 ]
Hillenius, Sem [1 ]
Bredenoord, Albert J. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Gastroenterol & Hepatol, NL-1105 AZ Amsterdam, Netherlands
关键词
esophagus; water-perfused manometry; normal values; pressure measurement; PRESSURE TOPOGRAPHY; MOTILITY;
D O I
10.1152/ajpgi.00447.2013
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Water-perfused high-resolution manometry (HRM) catheters with 36 unidirectional pressure channels have recently been developed, but normal values are not yet available. Furthermore, the technique has not been validated and compared with solid-state HRM. We therefore aimed to develop normal values for water-perfused HRM and to assess the level of agreement between water-perfused HRM and solid-state HRM. We included 50 healthy volunteers (mean age 35 yr, range 21-64 yr; 15 women, 35 men). Water-perfused HRM and solid- state HRM were performed in a randomized order. Normal values were calculated as 5th and 95th percentile ranges, and agreement between the two systems was assessed with intraclass correlation coefficient (ICC) statistics. The 5th-95th percentile range was 3.0-6.6 cm/s for contractile front velocity (CFV), 141.6-3,674 mmHg.s.cm for distal contractile integral (DCI), 6.2-8.7 s for distal contraction latency (DL), and 1.0-18.8 mmHg for integrated relaxation pressure (IRP 4s). Mean (SD) and ICC for water-perfused HRM and solid- state HRM were 4.4 (1.1) vs. 3.9 (0.9) cm/s, ICC: 0.49 for CFV; 1,189 (1,023) vs. 1,092 (1,019) mmHg.s.cm, ICC: 0.90 for DCI; 7.4 (0.8) vs. 6.9 (0.9) s, ICC: 0.50 for DL; and 8.1 (4.8) vs. 7.9 (5.1), ICC: 0.39 for IRP 4s. The normal values for this water-perfused HRM system are only slightly different from previously published values with solid- state HRM, and moderate to good agreement was observed between the two systems, with only small differences in outcome measures.
引用
收藏
页码:G491 / G495
页数:5
相关论文
共 50 条
  • [1] Normative values of water-perfused esophageal high-resolution impedance manometry in the Chinese population
    Tseng, Ping-Huei
    Chen, Chien-Chuan
    Lee, Yi-Chia
    Wang, Hsiu-Po
    Wu, Ming-Shiang
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 52 - 52
  • [2] VALIDATION OF A NEW WATER-PERFUSED HIGH-RESOLUTION MANOMETRY SYSTEM
    Mariotto, Rogerio
    Herbella, Fernando A. M.
    Angelo Andrade, Vera Lucia
    Schlottmann, Francisco
    Patti, Marco G.
    [J]. ABCD-ARQUIVOS BRASILEIROS DE CIRURGIA DIGESTIVA-BRAZILIAN ARCHIVES OF DIGESTIVE SURGERY, 2020, 33 (04):
  • [3] Normative values and factors affecting water-perfused esophageal high-resolution impedance manometry for a Chinese population
    Tseng, P. -H.
    Wong, R. K. M.
    Wu, J. -F.
    Chen, C. -C.
    Tu, C. -H.
    Lee, Y. -C.
    Lee, H. -C.
    Wang, H. -P.
    Wu, M. -S.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2018, 30 (06):
  • [4] Comparison of High-resolution Anorectal Manometry With Water-perfused Anorectal Manometry
    Kang, Hye Ran
    Lee, Ji-Eun
    Lee, Joon Seong
    Lee, Tae Hee
    Hong, Su Jin
    Kim, Jin Oh
    Jeon, Seong Ran
    Kim, Hyun Gun
    [J]. JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2015, 21 (01) : 126 - 132
  • [5] Normal values for esophageal high-resolution manometry
    Bogte, A.
    Bredenoord, A. J.
    Oors, J.
    Siersema, P. D.
    Smout, A. J. P. M.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (09): : 762 - E579
  • [6] High-resolution manometry in the evaluation of anorectal disorders: A simultaneous comparison with water-perfused manometry
    Jones, Michael P.
    Post, Jennifer
    Crowell, Michael D.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (04): : 850 - 855
  • [7] Diagnosis of Esophageal Achalasia Using Water-Perfused Catheter High Resolution Manometry
    Ortiz, Vicente
    Poppele, Guenter P.
    Castellano, Concepcion
    Garrigues, Vicente
    [J]. GASTROENTEROLOGY, 2013, 144 (05) : S263 - S263
  • [8] Software-Based Mathematical Recalibration for Position Change in Water-Perfused Esophageal High-Resolution Manometry System
    Rafaella Orlow
    Daniel Gualberto
    Fernando A. M. Herbella
    Francisco Schlottmann
    Marco G. Patti
    [J]. Journal of Gastrointestinal Surgery, 2022, 26 : 1084 - 1086
  • [9] Software-Based Mathematical Recalibration for Position Change in Water-Perfused Esophageal High-Resolution Manometry System
    Orlow, Rafaella
    Gualberto, Daniel
    Herbella, Fernando A. M.
    Schlottmann, Francisco
    Patti, Marco G.
    [J]. JOURNAL OF GASTROINTESTINAL SURGERY, 2022, 26 (05) : 1084 - 1086
  • [10] High-resolution anorectal manometry: A comparison of solid-state and water-perfused catheters
    Rasijeff, A. M. P.
    Withers, M.
    Burke, J. M.
    Jackson, W.
    Scott, S. M.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2017, 29 (11):