Impact of window and air-conditioner operation behaviour on cooling load in high-rise residential buildings

被引:10
|
作者
Yu, Cong [1 ]
Du, Jia [1 ]
Pan, Wei [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Pokfulam, Hong Kong, Peoples R China
关键词
occupant behaviour; air conditioning; natural ventilation; high-rise residential building; building energy use; OCCUPANT BEHAVIOR; OPENING BEHAVIOR; ENERGY USE; OFFICE; VENTILATION; PERFORMANCE; SIMULATION; MODEL;
D O I
10.1007/s12273-022-0907-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
Space cooling is an important building energy end-use that was found in recent years to be significantly impacted by occupant behaviours. However, the majority of previous studies ignored the interplay between the operation of windows and air conditioners (ACs) on cooling load, particularly in building energy modelling. In addition, studies on the analysis of cooling load characteristics regarding high-rise buildings are insufficient. The vertical effect of high-rise buildings on cooling load remains vague. This study thus aims to examine how window and AC operation behaviours impact the cooling load of high-rise buildings in an urban context demonstrated by a real-life typical 40-floor residential building in Hong Kong. This study investigates window and AC operation behaviours jointly and examines the vertical effect on cooling load by using agent-based building energy modelling (BEM) techniques and initiating stochastic and diverse behaviour modes. A carefully designed questionnaire survey was conducted to help build behaviour modes and validate energy models. Ninety building energy models were established integrating meteorological parameters generated by the computational fluid dynamics (CFD) programme for ten typical floors and nine combinations of window and AC behaviour modes. The results show that comfort-based AC modes and schedule-based window modes yielded the lowest cooling load. Considering the combined effect of AC and window uses, the maximum difference in cooling loads could be 26.8%. Behaviour modes and building height induce up to 32.4% differences in cooling loads. Besides, a deviation between the behaviour modes and height on the cooling load was found. The findings will help develop a thorough energy model inferring occupants' window and AC behaviour modes along with the building height in high-rise residential buildings. The findings indicate that the interaction impact of window and AC behaviour modes and height should be jointly considered in future high-rise building energy modelling, building energy standards, and policymaking.
引用
收藏
页码:1955 / 1975
页数:21
相关论文
共 50 条
  • [1] Impact of window and air-conditioner operation behaviour on cooling load in high-rise residential buildings
    Cong Yu
    Jia Du
    Wei Pan
    [J]. Building Simulation, 2022, 15 : 1955 - 1975
  • [2] Impact of Window Operation Behaviours on Cooling Load of High-rise Residential Buildings in Hong Kong
    Du, Jia
    Pan, Wei
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 2403 - 2410
  • [3] SURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS
    Habara, Hiromi
    Yasue, Rakuto
    Shimoda, Yoshiyuki
    [J]. BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 2007 - 2013
  • [4] High-rise residential buildings
    Lutz, Martin
    [J]. Stahlbau, 2015, 84 (S1) : 67 - 77
  • [5] Flow inside a recessed space outside a high-rise residential building due to heat rejection by one air-conditioner of window-type per story
    Bojic, M.L.
    Yik, F.W.H.
    Lee, M.M.
    [J]. HKIE Transactions Hong Kong Institution of Engineers, 2001, 8 (02): : 48 - 54
  • [6] Wall and air conditioner combination for the best energy and economic performance: Methodology demonstration for high-rise residential buildings
    Kumar, Gunjan
    De, Sudipta
    Thakur, Biswajit
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 300
  • [7] Investigations of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    [J]. THERMAL SCIENCES 2000, 2000, : 505 - 510
  • [8] Investigation of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 491 - 496
  • [9] Cooling energy evaluation for high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    [J]. ENERGY AND BUILDINGS, 2005, 37 (04) : 345 - 351
  • [10] Shifting air-conditioner load in residential buildings: benefits for low-carbon integrated power grids
    Ali, Syed Muhammad Hassan
    Lenzen, Manfred
    Huang, Jing
    [J]. IET RENEWABLE POWER GENERATION, 2018, 12 (11) : 1314 - 1323