3-D Displacement Measurement for Structural Health Monitoring Using Low-Frequency Magnetic Fields

被引:11
|
作者
Kypris, Orfeas [1 ]
Markham, Andrew [1 ]
机构
[1] Univ Oxford, Dept Comp Sci, Oxford OX1 3QD, England
基金
英国工程与自然科学研究理事会;
关键词
Displacement; magnetic fields; structural health monitoring; crack detection; damage detection; position measurement; concrete; BRIDGE DISPLACEMENT; EXPANSION JOINTS; CRACK DETECTION; SYSTEM; ACCELERATION; LOCALIZATION; TRACKING;
D O I
10.1109/JSEN.2016.2636451
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Smart structures of the future will require a cost-effective, easily deployable solution for structural health monitoring. High loads on structures cause stresses that may lead to expansion of gaps, which are of utmost importance when it comes to overall structural health, as they absorb excess stress. Existing methods for direct displacement measurement of expansion joints are not ideal, as they operate under line-of-sight assumptions, are sensitive to moisture, or employ moving parts. In addition, the majority of existing sensors for structural health monitoring are uniaxial, and hence are fundamentally unable to measure 3-D displacement. Importantly, none of the existing wireless sensors for structural health monitoring can be embedded in concrete. We propose a system that uses low-frequency magnetic fields to conduct 3-D displacement measurement directly from within concrete, with a median displacement error of 0.5 mm in all directions, with a maximum separation distance of 50 mm between the transmitter and the receiver. The sensors can be attached to the concrete surface after the building is erected, or can be included in the concrete mix at manufacture, to monitor displacement between gaps in expansion joints, perform crack detection in concrete ties for railroads and in pavements, as well as aid position measurement for the assembly of premanufactured concrete blocks. Embedment in concrete allows operation throughout the lifetime of a structure, providing early warning of impending disaster and helping to inform repair operations.
引用
收藏
页码:1165 / 1174
页数:10
相关论文
共 50 条
  • [1] Measurement of low-frequency magnetic fields
    Wolfmayr, Holger
    Ziemann, Peter
    [J]. Technische Sicherheit, 2017, 7 (11-12): : 54 - 58
  • [2] Using low-frequency pulsar observations to study the 3-D structure of the Galactic magnetic field
    Sobey, C.
    [J]. PEERING TOWARDS COSMIC DAWN, 2018, 12 (S333): : 151 - 156
  • [3] 3-D Microwave Displacement Sensor: 3-D Displacement Measurement Using a Single Microwave Transceiver
    Gou, Yingjie
    Xiong, Yuyong
    Ren, Zesheng
    Meng, Guang
    Peng, Zhike
    [J]. IEEE Transactions on Instrumentation and Measurement, 2024, 73
  • [4] Measurement and prediction method for low-frequency magnetic fields on railway vehicles
    Kato, Yoshihito
    Hasegawa, Hitoshi
    [J]. Quarterly Report of RTRI (Railway Technical Research Institute), 2015, 56 (02) : 137 - 142
  • [5] Low-frequency electrical and magnetic fields
    Angerer, Manfred
    [J]. Eisenbahningenieur, 1997, 48 (09): : 37 - 40
  • [6] Localization in 3-D Using Beacons of Low Frequency Magnetic Field
    Sheinker, Arie
    Ginzburg, Boris
    Salomonski, Nizan
    Frumkis, Lev
    Kaplan, Ben-Zion
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (12) : 3194 - 3201
  • [7] HUMAN HEALTH AND EXPOSURE TO LOW-FREQUENCY ELECTRIC AND MAGNETIC-FIELDS
    RAFFERTY, CN
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 7 - ENVR
  • [8] HEALTH-EFFECTS OF LOW-FREQUENCY ELECTRIC AND MAGNETIC-FIELDS
    TENFORDE, TS
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (01) : 56 - 58
  • [9] Natural and technogenic low-frequency magnetic fields as a potential health hazard
    SPbF IZMIRAN, Box 188, Muchnoǐ per. 2, 191023 St. Petersburg, Russia
    不详
    不详
    不详
    不详
    [J]. Usp Fiz Nauk, 7 (789-791):
  • [10] Natural and technogenic low-frequency magnetic fields as a potential health hazard
    Ptitsyna, NG
    Tyasto, MI
    Villoresi, G
    Dorman, LI
    Iucci, N
    [J]. USPEKHI FIZICHESKIKH NAUK, 1998, 168 (07): : 767 - 791