Suppression of atrial fibrillation by multisite and septal pacing in a novel experimental model

被引:19
|
作者
Becker, R [1 ]
Senges, JC [1 ]
Bauer, A [1 ]
Schreiner, KD [1 ]
Voss, F [1 ]
Kuebler, W [1 ]
Schoels, W [1 ]
机构
[1] Heidelberg Univ, Dept Cardiol, D-69115 Heidelberg, Germany
关键词
antiarrhythmic agents; arrhythmia (mechanisms); conduction (block); mapping; supraventr; arrhythmia;
D O I
10.1016/S0008-6363(02)00231-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To evaluate the preventive efficacy of multisite and septal atrial pacing in an experimental model. Methods: Sterile right atrial pericarditis was induced in 12 foxhounds to provide an anatomical substrate for atrial fibrillation (AF). As a trigger mechanism, atrial extrasystoles were simulated by constant asynchronous pacing at a cycle length of 1000 ms from randomly selected right or left atrial electrodes. using a biatrial epicardial multielectrode with 128 bipoles. Additionally, a transvenous pacing lead was screwed into the interatrial septum. Four electrodes located in the high and low right (HRA/LRA) and left atrium (HLA/LLA) were selected for preventive multisite stimulation. Constant pacing at a cycle length 30 ms below sinus rate was applied from the following site(s): HRA, septal. HRA+LRA, HRA+LLA, HRA+LRA+LLA and HRA+LRA+HLA+LLA (order randomized). Number and duration of AF episodes were studied during 10 min intervals, separated by 5 min pauses, respectively. To validate the model, the protocol was repeated 10 min after i.v. bolus administration Of D,D,L-sotalol (1 mg/kg body weight). Results: The number of AF episodes decreased with increasing number of pacing sites, reaching statistical significance compared to HRA stimulation for quadruple-site and single-site septal pacing only (P<0.05). Single-site serial was as efficient as quadruple-site pacing in suppressing AF. The duration of A-F episodes was not significantly affected by the pacing configuration. D,L-sotalol almost completely suppressed AF irrespective of the pacing configuration used. Conclusions: In this novel experimental model, quadruple-site and septal pacing effectively suppress paroxysmal AF. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:476 / 481
页数:6
相关论文
共 50 条
  • [1] Multisite or septal pacing for arrhythmia suppression in an experimental model of paroxysmal atrial fibrillation?
    Becker, R
    Bauer, A
    Senges, JC
    Voss, F
    Schoels, W
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 85A - 85A
  • [2] Multisite pacing in atrial fibrillation
    Caprioli, V
    PACEMAKER LEADS 1997, 1997, : 233 - 237
  • [3] Prevention of atrial fibrillation by multisite atrial pacing - Editorial
    Barold, SS
    JOURNAL OF ELECTROCARDIOLOGY, 2001, 34 (01) : 49 - 52
  • [4] Septal atrial pacing for the prevention of atrial fibrillation
    Hakacova, Nina
    Velimirovic, Dusan
    Margitfalvi, Peter
    Hatala, Robert
    Buckingham, Thomas A.
    EUROPACE, 2007, 9 (12): : 1124 - 1128
  • [5] Suppression of atrial fibrillation by atrial pacing
    Inoue, Noriko
    Ishikawa, Toshiyuki
    Sumita, Shinichi
    Kobayashi, Tsukasa
    Matsushita, Kohei
    Matsumoto, Katsumi
    Taima, Minoru
    Shimura, Miei
    Uchino, Kazuaki
    Kimura, Kazuo
    Umemura, Satoshi
    CIRCULATION JOURNAL, 2006, 70 (11) : 1398 - 1401
  • [6] Multisite electrode pacing for prevention of atrial fibrillation
    Saksena, S
    Delfaut, P
    Prakash, A
    Kaushik, RR
    Krol, RB
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (08) : S155 - S162
  • [7] Multisite Biatrial Pacing Protects Against Atrial Fibrillation in the Canine Model
    Hansen, James C.
    Latchamsetty, Rakesh
    Lavi, Nimrod
    Hastings, Roger
    Avitall, Boaz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A124 - A124
  • [8] Suppression of experimental atrial fibrillation in a canine model of rapid atrial pacing by the phosphodiesterase 3 inhibitor cilostazol
    Zhao, Zhiqiang
    Li, Ruiling
    Wang, Xinghua
    Li, Jian
    Xu, Xiaona
    Liu, Tong
    Liu, Enzhao
    Li, Guangping
    JOURNAL OF ELECTROCARDIOLOGY, 2020, 60 : 151 - 158
  • [9] Experimental Study of Atrial Fibrillation Cycle Length During Rapid Atrial Septal Pacing
    Luca, Adrian
    Yazdani, Sasan
    Vesin, Jean-Marc
    Virag, Nathalie
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [10] Dynamic atrial pacing (DAOTM) and multisite atrial pacing for prevention of atrial fibrillation:: The stadim trial
    Senatore, G
    Fazzari, M
    De Simone, A
    Stabile, G
    Vasquez, L
    Maddalon, M
    Moro, E
    EUROPACE 2001, 2001, : 413 - 417