Design of A Magnet with Constant gradient field for Nuclear Magnetic Resonance

被引:0
|
作者
Chen, Lele [1 ,2 ]
Zou, Changchun [1 ]
Sun, Dianqing [2 ]
Gu, Zhaobin [2 ]
机构
[1] China Univ Geosci Beijing, Beijing, Peoples R China
[2] Res Inst Petr Explorat & Dev Langfang, Langfang, Hebei, Peoples R China
关键词
Nuclear Magnetic Resonance (NMR); Gradient Field; Magnet;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The principle of constant gradient field NMR is same with the logging expert system, the state-of-the -art technology in the world, wherein, gradient design and 2D spectrum inversion algorithm are adopted to quicken the instrument measurement speed while the diffusion coefficients of a fluid can be measured and the information obtained via the measurement of instrument can be more complete and authentic. The Article mainly introduces a magnet for gradient constant field NMR from such aspects as the parameter calculation of the gradient field, the selection of magnetic materials, finite element calculation and analysis, and detector installation and debugging. Experimental data shows that the design can completely realize fast NMR inspection and 2D spectrum inversion.
引用
收藏
页码:968 / 977
页数:10
相关论文
共 50 条
  • [1] Coil and magnet design for nuclear magnetic resonance in inhomogeneous field
    Le Bec, Gael
    Yonnet, Jean-Paul
    Raoof, Kosai
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (12) : 3861 - 3867
  • [2] A unilateral magnet with an extended constant magnetic field gradient
    Garcia-Naranjo, Juan C.
    Mastikhin, Igor V.
    Colpitts, Bruce G.
    Balcom, Bruce J.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 337 - 344
  • [3] New Magnet Design for Fast-Field-Cycling Nuclear Magnetic Resonance
    Kruber, Stephan
    Farrher, German D.
    Anoardo, E.
    IEEE LATIN AMERICA TRANSACTIONS, 2013, 11 (01) : 251 - 256
  • [4] Design of a nuclear magnetic resonance fast field cycling air cored magnet
    Sousa, Duarte M.
    Marques, Gil D.
    Sebastiao, Pedro J.
    Ribeiro, Antonio C.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 636 - +
  • [5] Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design
    Paulsen, Jeffrey L.
    Franck, John
    Demas, Vasiliki
    Bouchard, Louis-S.
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (12) : 4582 - 4590
  • [6] Magnetic field gradient system for nuclear magnetic resonance microimaging
    Andrew, ER
    Inglis, BA
    Kempka, M
    Mareci, T
    Szczesniak, E
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1996, 4 (02): : 85 - 91
  • [7] Design of A Permanent Quadrupole Magnet with Adjustable Magnetic Field Gradient
    Dong, S. X.
    Li, B.
    Zhang, B. S.
    Wang, X. Q.
    Feng, G. Y.
    IPAC23 PROCEEDINGS, 2024, 2687
  • [8] Tailoring magnetic field gradient design to magnet cryostat geometry
    Trakic, A.
    Liu, F.
    Lopez, H. S.
    Wang, H.
    Crozier, S.
    2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, 2006, : 698 - 701
  • [9] Design of a Permanent Magnet Configuration for Nuclear Magnetic Resonance Logging
    Zhang, Yanli
    Geng, Xin
    Zhang, Dianhai
    Xie, Dexin
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 664 - 668
  • [10] Effect of Stochastic Dynamics on the Nuclear Magnetic Resonance in a Field Gradient
    Tothova, J.
    Lisy, V.
    ACTA PHYSICA POLONICA A, 2017, 131 (04) : 1111 - 1113