A Novel Technique for Fetal ECG Extraction Using Single-Channel Abdominal Recording

被引:37
|
作者
Zhang, Nannan [1 ]
Zhang, Jinyong [1 ,3 ]
Li, Hui [1 ]
Mumini, Omisore Olatunji [1 ,2 ]
Samuel, Oluwarotimi Williams [1 ,2 ]
Ivanov, Kamen [1 ,2 ]
Wang, Lei [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adavanced Technol, Shenzhen 518055, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Peoples R China
[3] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong 9990779, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
adaptive noise cancellation (ANC); non-invasive FECG extraction; smooth window (SW); singular value decomposition (SVD); single abdominal channel; EVENT-SYNCHRONOUS CANCELLATION; HEART; INTERFERENCE; TIME;
D O I
10.3390/s17030457
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-invasive fetal electrocardiograms (FECGs) are an alternative method to standard means of fetal monitoring which permit long-term continual monitoring. However, in abdominal recording, the FECG amplitude is weak in the temporal domain and overlaps with the maternal electrocardiogram (MECG) in the spectral domain. Research in the area of non-invasive separations of FECG from abdominal electrocardiograms (AECGs) is in its infancy and several studies are currently focusing on this area. An adaptive noise canceller (ANC) is commonly used for cancelling interference in cases where the reference signal only correlates with an interference signal, and not with a signal of interest. However, results from some existing studies suggest that propagation of electrocardiogram (ECG) signals from the maternal heart to the abdomen is nonlinear, hence the adaptive filter approach may fail if the thoracic and abdominal MECG lack strict waveform similarity. In this study, singular value decomposition (SVD) and smooth window (SW) techniques are combined to build a reference signal in an ANC. This is to avoid the limitation that thoracic MECGs recorded separately must be similar to abdominal MECGs in waveform. Validation of the proposed method with r01 and r07 signals from a public dataset, and a self-recorded private dataset showed that the proposed method achieved F1 scores of 99.61%, 99.28% and 98.58%, respectively for the detection of fetal QRS. Compared with four other single-channel methods, the proposed method also achieved higher accuracy values of 99.22%, 98.57% and 97.21%, respectively. The findings from this study suggest that the proposed method could potentially aid accurate extraction of FECG from MECG recordings in both clinical and commercial applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A Novel Framework for Maternal ECG Removal from Single-Channel Abdominal Recording
    Zhong, Wei
    Cao, Zhongping
    Guo, Xuemei
    Wang, Guoli
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2019, : 616 - 621
  • [2] Fetal QRS extraction from single-channel abdominal ECG using adaptive improved permutation entropy
    Mansourian, Nastaran
    Sarafan, Sadaf
    Torkamani-Azar, Farah
    Ghirmai, Tadesse
    Cao, Hung
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (02) : 563 - 573
  • [3] Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG
    Lee, Kwang Jin
    Lee, Boreom
    [J]. SENSORS, 2016, 16 (07)
  • [4] Fetal ECG extraction from single-channel maternal ECG using singular value decomposition
    Kanjilal, PP
    Palit, S
    Saha, G
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (01) : 51 - 59
  • [5] An Efficient Method for Fetal ECG Extraction From Single Channel Abdominal ECG
    Panigrahy, D.
    Rakshit, M.
    Sahu, P. K.
    [J]. 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 1083 - 1088
  • [6] A New Technology for Extracting Fetal ECG Signals from Single-channel Maternal Abdominal ECG Signals
    Wang, Wenbo
    Qian, Long
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2021, 48 (10): : 121 - 130
  • [7] Fetal ECG Extraction by Extended State Kalman Filtering Based on Single-Channel Recordings
    Niknazar, Mohammad
    Rivet, Bertrand
    Jutten, Christian
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (05) : 1345 - 1352
  • [8] Separation of Fetal-ECG From Single-Channel Abdominal ECG Using Activation Scaled Non-Negative Matrix Factorization
    Gurve, Dharmendra
    Krishnan, Sridhar
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (03) : 669 - 680
  • [9] A novel technique for the extraction of fetal ECG using polynomial networks
    Assaleh, K
    Al-Nashash, H
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (06) : 1148 - 1152
  • [10] Fetal ECG Extraction from a Single Abdominal ECG Signal using SVD and Polynomial Classifiers
    Ayat, M.
    Assaleh, K.
    Nashash, H.
    [J]. 2008 IEEE WORKSHOP ON MACHINE LEARNING FOR SIGNAL PROCESSING, 2008, : 250 - 254