Humeral BMD Can be Measured With DXA and Is Lower in the Surgical Arm After Total Shoulder Arthroplasty

被引:1
|
作者
Andersen, Lucas [1 ]
Krueger, Diane [1 ]
Bernatz, James [2 ]
Binkley, Neil [1 ]
Anderson, Paul A. [2 ]
Grogan, Brian [2 ]
机构
[1] Univ Wisconsin, Osteoporosis Clin Res Program, 2870 Univ Ave Ste 100, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Orthoped & Rehabil, Madison, WI USA
关键词
Key Words; total shoulder arthroplasty; DXA; distal humerus; proximal humerus; bone mineral density; shoulder; BONE-MINERAL DENSITY; TOTAL KNEE ARTHROPLASTY; FOLLOW-UP; PRECISION; HIP;
D O I
10.1016/j.jocd.2022.08.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: As arthroplasty leads to bone loss, we hypothesized that humeral bone mineral density (BMD) is lower after total shoulder arthroplasty (TSA) in the operative versus non-operative arm. However, there is no clinical approach to measure humeral BMD with dual-energy x-ray absorptiometry (DXA). The purposes of this pilot study were to develop DXA methodology to measure humerus BMD, propose humerus regions of interest (ROIs), compare TSA BMD to the non-operative arm, correlate humeral BMD with stan-dard sites, and evaluate measurement reproducibility. Methodology: Thirty-eight adults 1-5 years post-TSA had standard clinical DXA scans plus full humerus scans using the atypical femur fracture feature; precision was assessed in a subset (n = 32). Six custom ROIs were used to measure BMD throughout the humerus. Radius and humeral BMD were compared between arms by paired t-test and correlated ipsilaterally using Pearson's Correlation. Custom ROI BMD precision was assessed using the International Society for Clinical Densitometry (ISCD) advanced precision calculator. Results: Study included 38 subjects (24M/14F), with mean (SD) age and time post-surgery of 69.6 (7.7) years and 2.5 (1.3) years respectively. BMD was lower (p < 0.01) at all custom humerus sites (3.8% to 8.2%) on the surgical side but not different at radius sites. Humeral BMD correlated positively with ipsilateral ultra-distal and 1/3 radius (r = 0.54 to 0.86; p < 0.05). Custom BMD precision (%CV) ranged from 6.0-16.0%. Conclusions: Humerus BMD can be measured using DXA and is lower in the TSA arm. Radius BMD correlated with humeral BMD but was not lower in the surgical arm. BMD precision was worse than usual clinical sites; use of software optimized for the femur is a notable limita-tion and likely contributes to suboptimal precision. Further study to assess the clinical utility of humeral BMD is needed. Automation and optimization of these measurements should improve precision.
引用
收藏
页码:448 / 455
页数:8
相关论文
共 50 条
  • [1] Humeral technique in total shoulder arthroplasty
    Friedman, RJ
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (03) : 393 - +
  • [2] Surgical Complications After Reverse Total Shoulder Arthroplasty and Total Shoulder Arthroplasty in the United States
    Ma, Gabrielle C.
    Bradley, Kendall E.
    Jansson, Hayley
    Feeley, Brian T.
    Zhang, Alan L.
    Ma, C. Benjamin
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2021, 5 (07):
  • [3] Stemless Humeral Implants in Total Shoulder Arthroplasty
    Brabston, Eugene W.
    Fehringer, Edward V.
    Owen, Matthew T.
    Ponce, Brent A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (07) : E277 - E287
  • [4] HUMERAL FRACTURES AFTER SHOULDER ARTHROPLASTY
    WRIGHT, TW
    COFIELD, RH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09): : 1340 - 1346
  • [5] How sensitive is the deltoid moment arm to humeral offset changes with reverse total shoulder arthroplasty?
    Walker, David R.
    Kinney, Allison L.
    Wright, Thomas W.
    Banks, Scott A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 998 - 1004
  • [6] Biomechanical consequences of humeral component malpositioning after anatomical total shoulder arthroplasty
    Terrier, Alexandre
    Ramondetti, Silvio
    Merlini, Francesco
    Pioletti, Dominique D.
    Farron, Alain
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (08) : 1184 - 1190
  • [7] Surgical Management of Proximal Humeral Fractures: The Emerging Role of Reverse Total Shoulder Arthroplasty
    Cvetanovich, Gregory L.
    Frank, Rachel M.
    Chalmlmers, Peter N.
    Verma, Nikhil N.
    Nicholson, Gregory P.
    Romeo, Anthony A.
    ORTHOPEDICS, 2016, 39 (03) : E465 - E473
  • [8] PRECISION OF BMD MEASUREMENTS AROUND TOTAL ANKLE ARTHROPLASTY USING DXA
    Messina, C.
    Albano, D.
    Chianca, V.
    Corazz, A.
    Sconfienza, L. M.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 : S546 - S546
  • [9] Humeral Stem Design in Reverse Total Shoulder Arthroplasty
    Lehman, Andrew C.
    Su, Favian
    Feeley, Brian T.
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2024, 17 (12) : 616 - 624
  • [10] Is the humeral stem useful in anatomic total shoulder arthroplasty?
    Philippe Collin
    Tetsu Matsukawa
    Pascal Boileau
    Ulrich Brunner
    Gilles Walch
    International Orthopaedics, 2017, 41 : 1035 - 1039